Distech Controls Allure EC-Smart-Air Series Manuale utente

Allure™ EC-Smart-Air Series
Product Description
The Allure EC-Smart-Air communicating sensors combine precise environmental sensing for temperature, humidity and CO2 in a discrete and alluring
enclosure.
This document describes the hardware installation procedures for the Allure EC-Smart-Air Series sensors. This line of communicating sensors consists
of the following models:
£Allure EC-Smart-Air
£Allure EC-Smart-Air-H
£Allure EC-Smart-Air-C
£Allure EC-Smart-Air-CH
General Installation Requirements
For proper installation and subsequent operation of the device, pay special attention to the following recommendations:
£It is recommended that the product(s) be kept at room temperature for at least 24 hours before installation to allow any condensation that may have
accumulated due to low temperature during shipping/storage to evaporate.
£Upon unpacking the product, inspect the contents of the carton for shipping damages. Do not install damaged modules.
£The device is designed to operate under such environmental conditions as specified in its datasheet.
£Ensure proper ventilation of the device and avoid areas where corroding, deteriorating or explosive vapors, fumes or gases may be present.
£Do not drop the device or subject it to physical shock.
£If the device is used and/or installed in a manner not specified by Distech Controls, the functionality and the protection provided by the device may
be impaired.
£To ensure reading accuracy, handle the sensor with care, and avoid installing it on a vibrating surface.
Make connections to the product last. Yanking the cable while it is attached to the product can damage the
connector.
Any type of modification to any Distech Controls product will void the product’s warranty.
Take reasonable precautions to prevent electrostatic discharges to the product when installing, servicing, or
operating it. Discharge any accumulated static electricity by touching a grounded object with your hand before
handling the product.
Installation Guide

2 / 10
Device Markings
Certain markings (symbols) can be found on the side of the product and are defined as follows:
Symbol Description
CE marking: the device conforms to the requirements of applicable EC directives.
UKCA marking: the device conforms to the requirements of applicable Great Britain regulations.
UL marking: conforms to the requirements of the UL certification.
FCC marking: This device complies with FCC rules part 15, subpart B, class B.
Warning Symbol: Significant information required. Refer to the Hardware Installation Guide.
General Wiring Recommendations
Operating, handling, or servicing this product should be ensured by a qualified operator. Turn off the power
before any kind of servicing.
All wiring must comply with the electrical wiring diagrams, as well as with the applicable national and local electrical codes.
Device Dimensions
84 (3.30)
117
(4.60)
25 (0.99)
Figure1: Allure EC-Smart-Air - Front view and side view

3 / 10
34 (1.34)
21
(0.83)
17
(0.67) 56
(2.20) 58
(2.28)
82
(3.23)
5 (0.20) 10 (0.40)
5 (0.20)
7 (0.28)
7 (0.28)
Figure2: Allure EC-Smart-Air- Back plate view
Mounting Instructions
This product has been specifically designed for easy installation. However, certain conditions apply when choosing a suitable location for the device:
£The device should not be installed on an exterior wall.
£The device should not be installed near a heat source.
£The device should not be installed near an air discharge grill.
£The device should not be installed in a place where it can be affected by the sun.
£Install the device in an area that provides proper device ventilation. Nothing must restrain air circulation to the device.
£Models equipped with a CO2 sensor must be used in spaces that are periodically unoccupied (e.g. during evening or nighttime hours).
The sensor has not been designed for outdoor use.
Installation Procedure
1. Remove the security screw from the device.
2. Open the device by pushing in the tab on its bottom and then by pulling the bottom side of the front plate out.
3. Make sure that the mounting surface is flat and clean.
4. Align the back plate with the wall and mark the location of the mounting holes on the wall. Make sure to orient the proper side of the back plate facing
upwards.
5. Remove the back plate and drill holes in the wall if necessary.
6. Install anchors in the wall if necessary.
7. Pull all RJ-45 cables 15 cm (6”) out of the wall, and insert them through the central hole of the back plate.
8. Screw the back plate onto the wall. Do not overtighten.
9. Set the Subnet ID and the EOL termination with the DIP switch. See Setting the Allure EC-Smart-Air Sensor Subnet ID.
10.Connect the one or two RJ-45 cables into the sensor (reversible).
11.Gently push excess wiring back into the wall.
12.Reattach the front plate and make sure it clips tightly into place.
13.Install the security screw.
Connectors and DIP Switch Location
The Allure EC-Smart-Air Series sensors have the following connectors and onsite configurable DIP switches.

4 / 10
Figure3: Connectors and DIP switch locations
Allure EC-Smart-Air Sensor with a CO2 Sensor
The Allure EC-Smart-Air Series sensors equipped with a CO2 sensor are factory-calibrated to accurately read the CO2 concentration levels at sea level.
When these sensors are used in locations where the elevation is greater than 150 m (500 ft) above sea level, you need to set the Elevation input of the
sensor block in EC-
gfx
Program to the current location’s elevation to obtain the most accurate readings.
For more information, refer to the sensor block section in the EC-
gfx
Program User Guide.
Under normal conditions, an Allure EC-Smart-Air sensor with CO2 sensor will reach its operational accuracy after 24 hours of
continuous operation provided that it was exposed to ambient air reference levels of 400 ppm ±10 ppm CO2.
The sensor will maintain accuracy specifications using the automatic self-calibration, assuming that it is exposed to the
atmospheric CO2 concentration of 400ppm for at least 15 minutes per 7-day period, which is typically seen during unoccupied
periods.
Supported Quantity
The Allure EC-Smart-Air sensor connects to the controller’s Subnet Port. Other devices may also be connected to this port in a daisy-chained fashion
(see the controller’s datasheet for compatibility information and supported quantities).
Each controller supports a specific maximum number of Allure EC-Smart-Air sensors. The Subnet ID of all Allure EC-Smart-Air sensors must be set
within the indicated addressing range.
The Allure EC-Smart-Comfort Series and Allure EC-Smart-Air Series sensors share the same Subnet ID range: the same address
CANNOT be concurrently assigned to an Allure EC-Smart-Comfort Series sensor AND to an Allure EC-Smart-Air Series sensor.
Controller Model Room Devices Maximum Number of Room De-
vices
Permitted Subnet ID Addressing
Range
ECB-PTU Series
ECL-PTU Series
Total number of room devices 4-
Allure EC-Smart-Comfort
Allure EC-Smart-Air
4 1 to 4
Allure EC-Smart-Vue 4 1 to 4
EC-Multi-Sensor 4 1 to 4
ECY-VAV series Total number of room devices Up to 4 -

5 / 10
Controller Model Room Devices Maximum Number of Room De-
vices
Permitted Subnet ID Addressing
Range
ECB-VAV controller
ECL-VAV controller
Allure EC-Smart-Comfort
Allure EC-Smart-Air
Up to 4 1 to 4
Allure EC-Smart-Vue Up to 4 1 to 4
EC-Multi-Sensor Up to 4 1 to 4
For the permitted quantities according to the controller model and the connected RJ-45 accessories, see the room calculator spreadsheets available for
download on our website.
ECB-VAV-O
ECB-VAV-N
ECB-VAVS
ECB-VVTS
ECB-103
ECB-203 Series
ECB-VAV-O
ECB-VAV-N
ECB-VAVS
ECB-VVTS
ECB-103
ECB-203 Series
Total number of room devices 4 -
Allure EC-Smart-Comfort
Allure EC-Smart-Air
4 1 to 4
Allure EC-Smart-Vue 4 1 to 4
EC-Multi-Sensor 0 -
ECY-S1000 Series
ECB-300
ECB-400
ECB-600
ECL-300
ECL-400
ECL-600
Total number of room devices 12 -
Allure EC-Smart-Comfort
Allure EC-Smart-Air
6 1 to 6
Allure EC-Smart-Vue 12 1 to 12
EC-Multi-Sensor 0 -
Table1:
Maximum Number of Room Devices by Controller Model, and Allowed Addressing Range
Adding devices to the subnetwork decreases the system responsiveness. This may cause a certain delay, which could be an issue for
commands that require fast response, such as lighting and shades/sunblind commands.
The indicated addressing ranges are specific to each group of devices.
4 different Subnet ID codifications are used on the ECx Subnetwork :
£1 for Allure EC-Smart-Vue Series sensors
£1 for Allure EC-Smart-Comfort and Allure EC-Smart-Air sensors
£1 for EC-Multi-Sensors
£1 for ECx-Light/Blind Series expansion modules
Consequently, an Allure EC-Smart-Vue sensor and an Allure EC-Smart-Air sensor may share the same Subnet ID, but an Allure EC-
Smart-Air sensor and an Allure EC-Smart-Comfort sensor must have a different Subnet ID.
A controller can support a maximum of two (2) Allure Communicating Sensor models equipped with a CO2 sensor. Any remaining
connected Allure Communicating Sensor models must be without a CO2 sensor.
About the Subnetwork Bus
The controllers use the subnetwork bus to communicate with the room devices (see each controller’s datasheet for compatibility), including with the Al-
lure EC-Smart-Air sensors, by using standard structural (Cat 5e) cabling and by connecting the devices in a daisy-chained fashion to the controller’s
Subnet Port. For more information, please refer to the table in the --- MISSING LINK --- section of this document.
The maximum length of the Communicating Sensor subnetwork bus is 600 ft (180 m).

6 / 10
Figure4: Subnetwork Bus Overview
A controller can support up to two (2) room devices that are equipped with a CO2 sensor, i.e. the remaining connected devices must be without a CO2
sensor. To find out the number of room devices that a given controller model can support, please refer to the table in the --- MISSING LINK --- section of
this document.
To ensure proper operation, it is recommended to distribute the sensors as evenly as possible throughout the length of the subnetwork.
Figure5: Subnetwork Length and Distribution

7 / 10
For ECB/ECL-PTU Series controllers, the maximum length between two consecutive devices on the sub-network bus is 100 ft (30 m).
Subnetwork Bus Topology and EOL Terminations
Only a daisy-chain topology is acceptable for the room device subnetwork bus. T-connections are not allowed.
For controllers other than ECB-600 or ECL-600, only the EOL terminations of the last subnetwork bus device must be set to ON.
All other subnetwork bus devices must have their EOL terminations set to OFF.
The controller must be the first device on the Cat 5e Cable Subnetwork bus, because its internal EOL termination is permanently enabled.
The maximum number of room devices that a given controller model can support is indicated in the table of section Supported
Quantity [pg.4].
Figure6: Setting the EOL Terminations on the Allure EC-Smart-Air sensor for any controller other than the ECB/ECL-600 series con-
trollers and Smart Room Control controllers
Figure7: Setting the EOL Terminations on the Allure EC-Smart-Air Sensor for Smart Room Control controllers
When one or more room devices are installed with an ECB-600 / ECL-600 (without an ECx-4xx O Extension Module) controller:
£Only the EOL terminations on the ECB-600 / ECL-600 and the last room device are set to ON.

8 / 10
£All other room devices must have their EOL terminations set to OFF.
Figure8: Setting the EOL Terminations on the Allure EC-Smart-Air Sensor for ECB-600 or ECL-600 Series controllers
When ECx-4xx IO Extension Modules are installed with an ECB-600 / ECL-600 Series controller and with room device(s):
£Only the EOL terminations on the last ECx-4xx IO Extension Module and the last room device are set to ON.
£All other ECx-4xx IO Extension Modules and room devices must have their EOL terminations set to OFF.
Figure9: Setting the EOL Terminations when Allure EC-Smart-Air Sensors are used with ECx-4xx IO Extension Modules

9 / 10
ECx-4xx Series devices and room devices are factory-set with the EOL set to OFF by default.
Setting the Allure EC-Smart-Air Sensor Subnet ID
Each Allure EC-Smart-Air communicating sensor connected to a controller’s Subnet Port must be set to a unique subnet ID address. The address is set
through the DIP switch located next to the Subnet Port connectors. Please refer to section Connectors and DIP Switch Location [pg.3].
Switch Position Allure EC-Smart-Air Subnet
ID Address
1 2 3 4 (EOL)
OFF OFF OFF
ON or OFF
See Subnetwork
Bus Topology and EOL
Terminations
1
ON OFF OFF 1
OFF ON OFF 2
ON ON OFF 3
OFF OFF ON 4
ON OFF ON 5
OFF ON ON 6
The Allure EC-Smart-Comfort sensors and Allure EC-Smart-Air sensors share the same addressing range.
Maintenance and Cleaning
Gently clean the device with a soft, lint-free cloth slightly moistened with a solution of mild liquid dish soap and warm water or disinfect the device with a
soft cloth slightly moistened with a 70% isopropyl alcohol.
Do not directly spray any liquid or disinfecting solution on the device. Do not clean with any other chemicals products.

10 / 10 Allure EC-Smart-Air Series_IG_15_EN
Disposal
The Waste Electrical and Electronic Equipment (WEEE) Directive set out regulations for the recycling and disposal of products. The WEEE2002/96/EG
Directive applies to standalone products, for example, products that can function entirely on their own and are not a part of another system or piece of
equipment.
For this reason Distech Controls products are exempt from the WEEE Directive. Nevertheless, Distech Controls products are marked with the WEEE
symbol , indicating devices are not to be thrown away in municipal waste.
Products must be disposed of at the end of their useful life according to local regulations and the WEEE Directive.
FCC Statement
Changes or modifications not expressly approved by Distech Controls could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures:
£Reorient or relocate the receiving antenna.
£Increase the separation between the equipment and receiver.
£Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
£Consult the dealer or an experienced radio/TV technician for help.
©, Distech Controls Inc., 2015 - 2022. All rights reserved.
Images are simulated. While all efforts have been made to verify the accuracy of information in this manual, Distech Controls is not responsible for damages or claims arising from the use of this manual.
Persons using this manual are assumed to be trained HVAC specialist / installers and are responsible for using the correct wiring procedures and maintaining safe working conditions with fail-safe environ-
ments. Distech Controls reserves the right to change, delete or add to the information in this manual at any time without notice.
Distech Controls, the Distech Controls logo, Open-to-Wireless, Innovative Solutions for Greener Buildings, and Allure are trademarks of Distech Controls Inc. BACnet is a registered trademark of ASHRAE.
Global Head Office - 4205 place de Java, Brossard, QC, Canada, J4Y 0C4 - EU Head Office - ZAC de Sacuny, 558 avenue Marcel Mérieux, 69530 Brignais, France
Questo manuale è adatto per i seguenti modelli
4
Indice
Altri manuali Distech Controls Accessori

Distech Controls
Distech Controls Allure UNITOUCH Manuale

Distech Controls
Distech Controls HS-THX Manuale utente

Distech Controls
Distech Controls EC-Multi-Sensor Series Manuale

Distech Controls
Distech Controls GS-AQR Manuale

Distech Controls
Distech Controls EC-Multi-Sensor-BLE Manuale utente

Distech Controls
Distech Controls Allure EC-Smart-Vue Series Manuale utente

Distech Controls
Distech Controls Allure EC-Sensor Series Manuale

Distech Controls
Distech Controls UNIWAVE Manuale utente