Dive System iDive DAN Manuale utente

1
iDive DAN
User manual
2.0

2
Congratulations on purchasing your Dive System computer.
Dive System, with the quality of its products, has always been at your side to guarantee comfort, en-
joyment and safety in diving.
The Dive System computer that you purchased is an extremely modern computer which includes com-
prehensive software for recreational and technical diving.
The Dive System computer iDive DAN includes a decompression algorithm
supportive of air and nitrox dives, a complete algorithm integrates decompression and its processor
calculates in real time the specic dive prole of your dive, for the benet of exibility and safety
Check the www.divesystem.com website for any updates to the manual.
Introduction

3
Table of Contents
Introduction ________________________ 2
Table of Contents ____________________ 3
Cautions ___________________________ 5
General instructions _________________ 5
Danger warnings ___________________ 7
Nitrox Diving ______________________ 9
Before a dive ______________________ 10
Limits of the dive computer____________ 11
Care and Maintenance_______________ 11
Specications _______________________ 13
Menus and Functions_________________ 18
Backlight __________________________ 19
Battery level ________________________ 19
Information ________________________ 19
Compass __________________________ 20
Weather __________________________ 22
Atmospheric press., altim. and temp._____ 23
Clock _____________________________ 25
Dive ______________________________ 25
Gauge ____________________________ 26
Free Dive __________________________ 27
Settings____________________________ 28
Dive set ___________________________ 30
P. Safety - Security Level ______________ 30
Safety Stop _______________________ 32
Deep stop ________________________ 33
Max PPO2 ________________________ 34
Salt and Fresh water_________________ 35
Mix_______________________________ 36
Mix 1 ____________________________ 36
Mix 2 ____________________________ 37
Mix 3 ____________________________ 37
Planner____________________________ 38
Logbook __________________________ 40
Alarm _____________________________ 42
ASC Speed ________________________ 42
Max Depth________________________ 43
Deco Viol _________________________ 43
Display ____________________________ 44
BKL Level _________________________ 44
BKL Time _________________________ 45
Contrast _________________________ 45
Units ____________________________ 46

4
PC Mode __________________________ 47
Sys Set ____________________________ 48
UTC - Time zone ____________________ 48
Time ____________________________ 49
Format __________________________ 49
Date ____________________________ 50
Default ____________________________ 51
Compass __________________________ 52
Declin ___________________________ 52
Dir______________________________ 53
Calib ____________________________ 53
iDive during diving___________________ 55
Dive ______________________________ 55
NDL ______________________________ 55
CNS and temperature ________________ 56
Dive profile ________________________ 56
Extra Safety Stop ____________________ 57
Deep Stop _________________________ 58
Deco dive__________________________ 59
Dive compass ______________________ 60
Switch gas during dive _______________ 61
iDive - the data on the surface__________ 62
iDive after immersion_________________ 63
No-Fly ____________________________ 63
iDive in Gauge ______________________ 64
Gauge ____________________________ 64
iDive in Free ________________________ 66
Free mode during dive _______________ 66
Free mode on the surface _____________ 67
Summary

5
General instructions
This User’s Guide contains certain hazards and should be carefully read.
• It is essential to read this user manual before using the Dive System computer. The incorrect use of
the computer or its accessories will void the warranty and may cause permanent damage to the
computer itself and / or its accessories.
• The dive computer is NOT A SUBSTITUTE to scuba diving training and should be used only by divers
who have been properly trained
• The Dive System computer is an auxiliary tool to diving, therefore it is mandatory to always have an
adequate table in order to perform the decompression phase in the case of malfunction to the unit
• Diving carries risks related to decompression sickness, oxygen toxicity and other inherent risk and
even careful perusal of this manual and use of this instrument does not rule out potential dangers.
Anyone who does not understand or does not knowingly accept these risks should not dive with
the iDive computer.
• Diving has some inherent risks that can never be completely excluded. No dive table or compu-
ter can ever ensure that there are no Decompression Illness risk (DCI) or Central Nervous System
Cautions

6
Oxygen Toxicity even if the diver scrupulously and correctly follows the instructions of dive tables or
computers.
• The computer is not able to take into account individual physiological variations that can alter day
to day and for this reason it is good practice to use this instrument in a conservative and precau-
tionary manner, remain well within the limits set by the computer in order to minimize the risk of
decompression sickness and oxygen toxicity to the central nervous system.
• The computer does not replace decompression training of tables that you always want to have as a
backup together with a depth gauge and watch.
• It is prohibited to share a single computer for two divers while diving, each diver must carry their
own instrument which provides information only to them.
• It is prohibited to dive with a computer that did not take into account previous dives made by the
diver, its calculation can never take into account data that it does not know.
• Personal Safety factors: carefully read the detailed instructions on how to set up and choose the
appropriate level. The 0 to 3 value scale provides a higher level of conservatism with the increase of
its value.
Cautions

7
Danger warnings
• The computer is NOT intended for PROFESSIONAL use! The computer is intended for sports use only.
• Non compliance to the above may expose the diver to an increased risk of incurring decompression
illness (DCI) It is therefore not recommended for commercial or professional diving.
• Before diving you must check the battery level, DO NOT dive with the battery level of 30% or lower,
check that the display does not show any sign of malfunction and that it is legible.
• Check that the settings correspond to those desired.
Cautions

8
• Keep in mind that our body has daily variations of which the computer cannot take into account.
• You must avoid all behavior that increase risks associated with decompression sickness such as rapid
ascents, yo-yo diving, decompression stop obligations, dives with surface intervals too close toge-
ther and by any other behavior not dictated by common sense and training.
• However the use of the instrument, does not allow its use without due preparation through specic
training. Failure to follow the basic rules of diving exposes the diver to life threatening circumstan-
ces. We recommend diving within the safety curve in order to reduce risks associated with decom-
pression sickness.
• We recommend not exceeding 40 meters diving or based on the oxygen % value within the cylinder,
max 1.4 BAR PpO2. Exposure to higher values exposes the diver to life-threatening conditions.
• We do not recommend diving with Mandatory Safety Stops.
• Comply with the ascent rate recommended by the instrument, an excessive ascent rate exposes the
diver to life threatening conditions.
• The computer calculates the total time of ascent but may be longer than that displayed according to
certain parameters that the computer recalculates throughout the dive, try to use the correct ascent
Cautions

9
speed, observing the depth stops displayed helps meet this duration.
• No FLY Time: it is prohibited to board a plane if the NO FLY TIME icon on the display is still on. Re-
member to plan the last dive of the series taking into account the recommendations provided by
DAN (Divers Alert Network).
• Even if you meet all the set intervals, we cannot exclude the onset of decompression disease while
ying after diving.
Nitrox Diving
• Setting the oxygen fraction contained in a cylinder the computer will only take into account whole
numbers such as when 32.8 percentage of oxygen is used, a whole number value that is less than 32
should be set. Do not round to a top number as this will underestimate calculations relating to the
nitrogen.
• Check the PpO2 max settings and never exceed the 1.4 BAR value.
• DO NOT DIVE without checking the contents of the cylinder with declared reliable instruments.
Check the gas settings on the computer to match those contained in the cylinder with which you
will dive with.
Cautions

10
• Diving with Nitrox requires specic training, DO NOT dive without due training. Exceeding the maxi-
mum PpO2 settings and those recommended imposes an immediate ascent to a lower level and in
the event of a CNS value (Central Nervous System) approaches the recommended limits we advise a
reduction of oxygen exposure.
Before a dive
• Use the dive computer only after reading the instruction manual in its entirety and you thoroughly
understand its operation. In cases of doubt or questions, please contact your dealer before diving.
• It important to understand that every diver is totally responsible for their own safety.
• Diving with gas mixtures involve dierent risks from those associated with standard air diving. You
need proper training to learn how to understand and avoid such risks, which are not readily ascer-
tainable. These risks include possible serious injury or death.
Cautions
Questo manuale è adatto per i seguenti modelli
2
Indice

















