DMP Electronics 1168 Guida all'installazione

INSTALLATION AND PROGRAMMING GUIDE
1168 Wireless Smoke/CO/
Low Temp Detector


About the 1168 ............................................ 1
Indicator LEDs ....................................................... 1
Power Supply......................................................... 1
Voice Annunciation.............................................. 1
Tamper Magnet ..................................................... 1
Cadence Synchronization ............................... 2
Low Temp Sensor................................................ 2
1168 Features...............................................3
Program the Detector................................4
Fire/Smoke Zone................................................. 4
Program Start Display ....................................... 4
Zone Information................................................. 4
Zone Number........................................................ 4
Zone Name............................................................. 4
Zone Type............................................................... 4
Fire Bell Out........................................................... 5
Next Zone............................................................... 5
Wireless................................................................... 5
Serial Number ....................................................... 5
Contact Type......................................................... 5
Supervision Time ................................................. 5
TABLE OF CONTENTS
Next Zone............................................................... 5
Carbon Monoxide Zone .................................... 6
Zone Number........................................................ 6
Zone Name............................................................. 6
Zone Type............................................................... 6
Fire Bell Out........................................................... 6
Next Zone............................................................... 6
Wireless................................................................... 7
Serial Number ....................................................... 7
Contact Type......................................................... 7
Supervision Time ................................................. 7
Next Zone............................................................... 7
Low Temperature Zone..................................... 8
Zone Number........................................................ 8
Zone Name............................................................. 8
Zone Type............................................................... 8
Fire Bell Out........................................................... 8
Next Zone............................................................... 8
Wireless................................................................... 8
Serial Number ....................................................... 9
Contact Type......................................................... 9
Supervision Time ................................................. 9

Next Zone............................................................... 9
Bell Options ........................................................... 9
Fire Bell Action..................................................... 9
Select a Location...................................... 10
Install the Detector ................................... 11
Mounting Guidelines ................................ 13
Authority Having Jurisdiction .......................14
Locations to Avoid.............................................15
Commercial ..........................................................16
Multi-Family..........................................................16
Test the 1168.............................................. 17
Smoke Test............................................................17
CO Test ...................................................................17
Additional Information ........................... 20
Reset the Language Selection .....................20
Supervision Message........................................20
Inspection Testing and Maintenance ..........21
Replace The Batteries.......................................21
NFPA 72 Guidelines.......................................... 22
Compliance Specifications......................27
Patents................................................................... 27
Certifications.............................................28
Compatibility .....................................................28
Certifications.......................................................28

Digital Monitoring Products, Inc. | 1168 Installation and Programming Guide 1
The 1168 Wireless Smoke/CO/Low Temp Detector features multi-criteria smoke sensing
using a combination of photoelectric, heat, IR flame flicker, and carbon monoxide
indicators. When multiple triggers are not present the smoke detector will also report after
being exposed to alarm levels of smoke for 5 minutes. The 1168 reports fire, CO, and low
temp alarms to the control panel. Use the onboard wireless transmitter to connect the 1168
with DMP1100Series Wireless Receivers.
Indicator LEDs
The 1168 has a multi-color top LED that
indicates the state of the device:
• GREEN—Supervisory indication;
blinks during power on, reset, and
during normal operation
• AMBER—Signal maintenance and
trouble events
• RED—Alarm (Smoke/CO)
Indicator lights on the side alarms
(initiating detector only):
• RED—Smoke
• BLUE—CO
ABOUT THE 1168
Power Supply
The 1168 is powered by four 3.0V lithium
batteries. Battery life expectancy for the
unit is at least three years under normal
conditions.
Voice Annunciation
The 1168 audibly announces alarm and
maintenance requirements, enhancing
occupant understanding and evacuation.
See LED Indication and Sounder table.
Tamper Magnet
The 1168 features a tamper magnet which
sends a trouble message to the panel if the
detector is removed from the mounting base.

2 1168 Installation and Programming Guide | Digital Monitoring Products, Inc.
Cadence Synchronization
The 1168 provides cadence synchronization
with other 1168 or 1164 units on the system.
Low Temp Sensor
The 1168 includes a low temperature sensor
that sends a message to the panel when
inside temperature falls below 41°F (5°C).

Digital Monitoring Products, Inc. | 1168 Installation and Programming Guide 3
1168 FEATURES
Figure 1: Product Features
CO Test Button Smoke Test Button
Indicator
LED
IR Flame
Detector
Indicator
Lights
CO Entry
Port
Indicator
Lights

4 1168 Installation and Programming Guide | Digital Monitoring Products, Inc.
PROGRAM THE DETECTOR
When programming an 1168 Wireless Smoke/CO/Low Temp Detector, refer to the
appropriate panel programming guide as needed.
Program Start Display
Enter 6653 (PROG) at the keypad to enter the PROGRAMMER
menu.
Zone Information
Press CMD until ZONE INFORMATION displays. Press a select
key or area to enter the menu.
Zone Number
Enter the zone number. Press CMD.
PROGRAMMER
ZONE INFORMATION
ZONE NO:
The 1168 takes up to three zone numbers (Smoke, CO, Temp). The zone numbers must be
consecutive.
Zone Name
Denote the zone name as a fire zone. Press CMD.
Zone Type
Press any select area. Press CMD to move to the next set of
menu options. Select FI (fire) as the ZONE TYPE.
* UNUSED *
ZONE TYPE
FI PN EM SV
Fire/Smoke Zone

Digital Monitoring Products, Inc. | 1168 Installation and Programming Guide 5
Fire Bell Out
Default is 0. Press CMD
Next Zone
At the NEXT ZONE? prompt, select NO.
Wireless
At the WIRELESS? prompt, select YES.
Note: If you are programming the 1168 onto a zone that
can be either hardwired or wireless, then this prompt
appears. If the zone you are programming is wireless-only,
then the prompt does not appear.
Serial Number
Enter the eight-digit serial number found on the device and
press CMD.
Contact Type
Enter the CONTACT type as FIRE and press CMD.
Supervision Time
Enter the SUPVSN TIME, and press CMD.
Next Zone
At the NEXT ZONE? prompt, select YES.
FIRE BELL OUT: 0
NEXT ZONE? NO YES
WIRELESS? YES
TRANSMITTER
SERIAL #: -
CONTACT: FIRE
SUPVSN TIME: 240
NEXT ZN? YES

6 1168 Installation and Programming Guide | Digital Monitoring Products, Inc.
Zone Number
Enter the zone number. This number must be consecutive
with the previous zone. For example, if 500 was entered for
Fire,501 should be entered here. Press CMD.
Zone Name
Denote the zone name as a carbon monoxide (CO) zone.
Press CMD.
Zone Type
Press any select area. Press CMD to move to the next set of
menu options. Select CO (carbon monoxide) as the ZONE
TYPE.
Fire Bell Out
Default is 0. Press CMD
Next Zone
At the NEXT ZONE? prompt, select NO.
ZONE NO:
* UNUSED *
ZONE TYPE
CO IN
FIRE BELL OUT: 0
NEXT ZONE? NO YES
Carbon Monoxide Zone
Altri manuali per 1168
1
Indice
Altri manuali DMP Electronics Rilevatore di fumo
Manuali Rilevatore di fumo popolari di altre marche

System Sensor
System Sensor DH500ACDC Manuale utente

Resolution Products
Resolution Products RE612 CryptiX Manuale utente

First Alert
First Alert PC900V Manuale utente

Eminent
Eminent EM6590 E-Domotica Manuale utente

Ei Electronics
Ei Electronics Ei Ei168RC Manuale utente

Carrier
Carrier Kidde Quell Q301 Manuale utente