DPS Telecom SiteMON IP G2 Manuale utente

USER MANUAL
SiteMON IP G2
May 21, 2012 D-OC-UM109.21100 Firmware Version 2..0B
Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs.

© 2010 DPS Telecom
This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this
document may be photocopied without prior written consent of DPS Telecom.
All software and manuals are copyrighted by DPS Telecom. Said software and manuals may not be reproduced, copied,
transmitted or used to make a derivative work, by either mechanical, electronic or any other means in whole or in part,
without prior written consent from DPS Telecom, except as required by United States copyright laws.
The material in this manual is for information purposes and is subject to change without notice. DPS Telecom shall not be
liable for errors contained herein or consequential damages in connection with the furnishing, performance, or use of this
manual.
Notice
Revision History
May 21, 2012
February 8, 2012
Sept. 21, 2010
Apr. 22, 2010
Oct. 7, 2009
Updated specifications to include camera resolution
Added Firmware upgrade section
Added Part Num. to Shipping List
Added info on new camera settings (digital pan and adv settings)
Initial release of D-OC-UM09A.07100.

ContentsVisit our website at www.dpstelecom.com for the latest PDF manual and FAQs
SiteMon IP Overview1 1
Shipping List2 2
Specifications3 4
Hardware Installation4 5
Tools Needed4.1 5
Mounting4.2 5
Installing the Outdoor Enclosure4.3 6
SiteMON IP G2 Back Panel5 7
Power Connection5.1 7
LAN Connection5.2 8
Discrete Alarms5.3 8
Control Relay Outputs5.4 8
+12 or +24VDC Sensor Power Supply5.5 9
Internal and External Temperature Sensors5.6 9
SiteMON IP's LEDs6 10
Configuring the SiteMON IP7 11
Connecting to the SiteMON IP8 11
... via Craft Port8.1 11
... via LAN8.2 12
TTY Interface9 13
Menu Shortcut Keys9.1 14
Unit Configuration9.2 14
Ethernet Port Setup9.2.1 14
SiteMON IP Web Browser10 16
Unit Configuration10.1 16
Logging on to the SiteMON IP10.1.1 16
Entering System Settings10.1.2 17
Changing the Logon Password10.1.3 18
Configuring Ethernet Settings10.1.4 18
Setting Up SNMP10.1.5 19
Configuring Base Discrete Alarms10.1.6 20
Defining Triggers10.1.7 21
Setting Web Timer10.1.8 22
Setting the Date and Time10.1.9 22
Adjusting the Camera Settings10.1.10 23
Setting System Alarm Notifications10.1.11 24

Temperature Sensors10.1.12 25
Configuring the Control Relays10.1.13 26
Saving Changes or Resetting Factory Defaults10.1.14 26
Rebooting the SiteMON IP10.1.15 27
Web Monitoring10.2 27
Viewing Live Images10.2.1 27
Viewing Triggered Images10.2.2 28
Monitoring Base Alarms10.2.3 29
Monitoring Temperature10.2.4 29
Monitoring System Alarms10.2.5 29
Operating Controls10.2.6 30
Firmware Upgrade10.2.7 30
Reference Section11 31
Display Mapping11.1 31
SiteMON IP Alarm Map Details11.1.1 31
SNMP Manager Functions11.2 32
SNMP Granular Trap Packets11.3 33
Frequently Asked Questions12 34
General FAQs12.1 34
SNMP FAQs12.2 36
Technical Support13 37
End User License Agreement14 38

1
SiteMon IP Overview1
The SiteMON IP G2 is part RTU, part camera - offering everything you need
to take remote site security to the next level.
The SiteMON IP G2 — Achieve Visual Remote Site Visibility
With the SiteMON IP G2, you don’t have to wonder what’s happening at your sites. You can see for yourself.
Added security for co-location sites can now be provided using the SiteMON IP G2. The SiteMON IP G2 reports
directly to your T/Mon or PC and delivers high-quality image viewing of your remote site. This provides a great
advantage for co-location sites where chances for interference with your equipment are particularly high.
With multiple vendors co-locating equipment at each site, and each vendor having its own support staff,
opportunities for interference with your equipment increase, malicious or not. Simply put, the more people with
access to your equipment, the more security issues arise. No longer will network managers be forced to sit and
wonder what is happening at their remote sites - hoping everything is fine. Now they’ll be able to view live
images from their sites and equipment with T/GFX, or cache them on a local PC for viewing later. The
SiteMON IP G2 is also valuable for walking technicians through repairs from the comfort of your central office.
With the SiteMON IP G2, you can:
·Capture images 6X faster than the previous model
·NEW! Digital pan for viewing live images
·Mount the camera at harsh weather sites with the wide-temp chassis design
·Enhance security both inside and out with the option for an exterior camera casing
·View live images in T/GFX or cache them on your PC for playback later
·New! Store up to 63 images locally or 10,000 using T/Mon's image receiver job
·Detect fault conditions (like motion sensors and doors) with 2 local alarm inputs
·Operate devices remotely (like turning on lights and unlock doors) with 2 local relay outputs
·Visually confirm who has arrived on-site before granting them access
·Track changing environmental conditions with internal and external temperature sensors
·Power peripherals (like motion sensors) with 12 or 24VDC power
·Use the integrated web browser to change configuration settings and monitor from any PC on the network

2
Shipping List2
While unpacking the SiteMON IP G2, please make sure that all of the following items are included. If some parts
are missing, or if you ever need to order new parts, please refer to the part numbers listed and call DPS Telecom
at (800) 622-3314.
SiteMON IP G2 SiteMON IP G2 User
D-PK-CAMRA Manual D-OC-UM109.21100
SiteMON IP G2 Resource CD One Ethernet Cable 14 ft.
(includes manuals, MIBs, and software) D-PR-923-10A-14
One 1/2-Amp GMT Fuse One Large Power Connector Plug
Two 3 Pin Analog Connector
2-820-00813-02 DB9M-RJ11 Cable
D-PR-1011-10A-06
One Small Power Connector Camera Mounting Arm
Plug for Sensor Output

3
One 4 Pin Connector
Optional Items
Two 1/2-Amp GMT Accessory Fuses
External Temperature Sensor Outdoor Enclosure for SiteMON IP G2
D-PR-984-10A-10

4
Specifications3
Discrete Alarm Inputs: 2
Temperature Sensors: 2 (1 internal, 1 external)
Control Relays: 2 Form C
Maximum Voltage: 60 VDC/120 VAC
Maximum Current: 1 Amp, AC/DC
Protocols: SNMP, TELNET, DCP, HTTP
Interfaces: 1 RJ45 10BaseT Ethernet port
1 RJ11 Craft port connector
1 stereo jack connector (for external temperature sensor)
1 4-pin connector for alarm inputs
1 2-pin connector for 12V or 24V power output for sensors
2 3-pin connectors for controls
Camera Resolution: 3 megapixel
Local Image Capacity: 63 Images
Dimensions: 6.959" D x 3.122" W x 2.750" H (without outdoor enclosure)
13" D x 5.5" W x 4.250" H (with outdoor enclosure)
Weight:1.168 lbs. (Without mounting arm or enclosure)
3.824 lbs. (With mounting arm and enclosure)
Mounting: Wall mounted
Power Input: –48VDC (–40 to –70 VDC), AC power options also available
Power Output: 12 VDC (standard) or 24VDC power output for peripherals
Current Draw: 100 mA (at -48V)
500 mA (Using heater)
Fuse: 1/2 amp GMT
Visual Interface: 6 LEDs
Operating Temp: -22 to 149 F (-30 to 65 C)
Operating Humidity: 0%–95% noncondensing
RoHS: 5 of 6

5
Hardware Installation4
Tools Needed4.1
To install the SiteMON IP G2, you'll need the following tools:
Phillips No. 2 Screwdriver Small Standard No. 2 Screwdriver
PC (for initial configuration via TTY interface)
Mounting4.2
Use the provided screws to wall mount the SiteMON IP G2. Both screws are used to mount the arm to the wall.
The SiteMON IP G2 is wall-mounted.

6
Installing the Outdoor Enclosure4.3
The optional metal enclosure is a hard casing used for mounting the SiteMON IP G2 outdoors. To install the
camera inside the enclosure, perform the following steps:
1. Remove (unsnap) the black bracket from the inside of the enclosure.
2. Using a Phillips No.2 screwdriver and the large screw provided, attach the black bracket to the underside
of the camera.
The SiteMON IP G2 inside the enclosure.
3. Snap the camera inside the enclosure and slide it along the track to the desired position.
4. Secure the SiteMON in place by screwing in the 2 small screws provided.
5. Turn the metal lock on the back of the enclosure to close the lid. You may also attach a padlock to prevent
others from opening the enclosure.
The SiteMON IP G2 inside the
enclosure.
The SiteMON IP G2 inside the enclosure.
Questo manuale è adatto per i seguenti modelli
1
Indice