Dr.Care XREAL Manuale utente

DR-XR 955S
www.drcare.us
XREAL Massage chair
Made By
Dr.Care International Inc.
Tel:
www.drcare.us
California, 90040, The U.S.A
6565 E. Washington Blvd., Commerce,
22
DR-XR 955S This document is copyrighted by Dr.Care International Inc.
+1 (229) 800.0009


1
INTRODUCTION
Brian Williams
Thank you for choosing Dr.Care`s products!
XREAL massage chair is a high technology item to improve your health, to relax
your body after a hard working day. There will be no more stress, any aches or
pains, … XREAL massage massage chair will bring you more for a happy life, an
optimism, sound mind and sound body.
With over 24 years experience in the field of researching and manufacturing health
care products, Dr.Care are non-stop researching and developing to create the
modern unique leading products, more and more professional massage technique
to satisfy Dr.Care`s customers.
To achieve the highest efficiency in treating pains and health recovery, please care-
fully read this User Manual book.
We always look forward to serving you better.
Your sincerely,
40
CONTENTS
Introduction:...............................................1
Safety
Introduction:....................................3
Product Specifications:...............................4
Product componentnames:.........................5
Functions:...................................................6
Standard functions:.....................................7
Operation Guide:.........................................8
Maintenance:..............................................30
Safety Introduction:.....................................31
illustration:..................................................34
Maintainance History:.................................36
Contents:.....................................................40
DR-XR 955SDR-XR 955S
DR-XR 955S - USM/22
This document is copyrighted by Dr.Care International Inc. This document is copyrighted by Dr.Care International Inc.

2
SAFETY INTRODUCTION
cian
electrician.
39
MAINTENANCE HISTORY
Date:
Problems:
Solution:
Signed by Technician
..............................................................................................................
..............................................................................................................
Date:
Problems:
Solution:
Signed by Technician
..............................................................................................................
..............................................................................................................
Date:
Problems:
Solution:
Signed by Technician
..............................................................................................................
..............................................................................................................
DR-XR 955S DR-XR 955S
DR-XR 955S - USM/22
This document is copyrighted by Dr.Care International Inc. This document is copyrighted by Dr.Care International Inc.

3
SAFETY INTRODUCTION
26. Do not operate where aerosol (spray) products are used or where oxygen is being
administered.
(including children) with reduced
instruction by a person responsible for their safety.
38
MAINTENANCE HISTORY
Date:
Problems:
Solution:
Signed by Technician
..............................................................................................................
..............................................................................................................
Date:
Problems:
Solution:
Signed by Technician
..............................................................................................................
..............................................................................................................
Date:
Problems:
Solution:
Signed by Technician
..............................................................................................................
..............................................................................................................
DR-XR 955S DR-XR 955S
DR-XR 955S - USM/22
This document is copyrighted by Dr.Care International Inc. This document is copyrighted by Dr.Care International Inc.

4
PRODUCT SPECIFICATIONS
37
MAINTENANCE HISTORY
Date:
Problems:
Solution:
Signed by Technician
..............................................................................................................
..............................................................................................................
Date:
Problems:
Solution:
Signed by Technician
..............................................................................................................
..............................................................................................................
Date:
Problems:
Solution:
Signed by Technician
..............................................................................................................
..............................................................................................................
DR-XR 955S DR-XR 955S
PRODUCT NAME
MODEL
RATED VOLTAGE
RATED INPUT
RATED FREQUENCE
SAFETY DESIGN
SERIAL NUMBER
XREAL massage chair
DR-XR 955S
120V~
240W 2.0A
60Hz
CLASS I
100%
GENUINE
LEATHER
XREAL massage chair
:
:
:
:
:
:
:
Inc.
6565 E. Washington Blvd., Commerce,
California, 90040, The U.S.A
DR-XR 955S
DR-XR 955S - USM/22
This document is copyrighted by Dr.Care International Inc. This document is copyrighted by Dr.Care International Inc.

5
PRODUCT COMPONENT NAMES
Main Body Diagram
1
2
3
9
10
5
6
18
20
13
12
15
21
14
8
4
16
11
17
22 23
7
19
1.Pillow Pad
2.3D Digital Audio
3.Arm Air Bag Assembly
4.Seat Cushion
5.Calf Massage Assembly
6.Foot Massage Assembly
7.Negative Oxygen Ion Function
8.Upper Arm Air Bag Assembly
9.Back Cushion
10.Armrest
11.Armrest decoration
12.Side cover
13.Back Cover
14.Controller
15.Controller Pocket
16.Driving Box Cover
17.Safety switch
18.Caster Wheels
19.Power Cord and Plug
20.Power socket
21.Fuse Box
22.Power Switch
23.Controller Cord Socket
36
MAINTENANCE HISTORY
Date:
Problems:
Solution:
Signed by Technician
..............................................................................................................
..............................................................................................................
Date:
Problems:
Solution:
Signed by Technician
..............................................................................................................
..............................................................................................................
Date:
Problems:
Solution:
Signed by Technician
..............................................................................................................
..............................................................................................................
DR-XR 955S DR-XR 955S
DR-XR 955S - USM/22
This document is copyrighted by Dr.Care International Inc. This document is copyrighted by Dr.Care International Inc.

6
FUNCTIONS
·This product is designed with a set of smart 3D mechanical hands, which can move
up and down, stretching back and forth, four-wheel driven with muted design.
·The shoulder part is designed with automatic detection and micro adjustment
function; body curve and massage points automatic detection, it can automatically
adjust the distance of massage hands' moving back and forth according to the
detected body curve and massage points, to make the massage more humanistic
and scientific.
·Comfort, ease, ache relieve, fast experience, relax, music sync, waist stretch, full
air pressure and other specific massage functions.
·Set with two kinds memo massage functions M1 and M2.
·Manually select the upper body massage; three massage position options of
overall, partial and fixed position; six massage methods of shoulder grasping,
kneading, tapping, shiatsu, kneading & tapping and 3D; five massage speed levels
available; under tapping and shiatsu massage status, the width of the massage
hands can be adjusted in five levels.
·Arm air massage function (built-in 8 air bags), upper arm air massage function
(built-in 4 air bags), with 3 intensity adjustments.
·Lower body air pressure massage function: back air pressure massage function
(built-in 4 airbags), buttock air pressure massage (built-in 16 airbags), calf rest air
pressure massage function (built-in 36 airbags), with 3 intensity adjustments.
·On upper arm has two grades width adjustment function When you adjust to the
last grade, to push into the arm about a gear distance then lose your hand and arm
device will automatically reset, and so on in order to adapt to the dif ferent
Shoulder breadth of users.
·Back heating function, use carbon fiber as infrared heating source.
·The footrest can be extended to suit various heights.
·With slide rail structure on backrest, make a zero-space design to maximally save
place.
·Calf rest lifting, backrest lifting and auto lying models adjustment.
·With negative oxygen ionizer on upper arm.
·Intelligent terminal (cell phone or tablet PC) control the massage chair by blue
tooth.
·MP3 player function, upper arm built in 3D digital audio.
·Connect the smart device via blue tooth to play music .
·Auto massage program download.
·Place 8 natural energy magnet in calf air bags.
35
ILLUSTRATION
Acupressure Point Massage Instruction
Every Vertebra is related with the health, for example:
6. The ninth bone of chest vertebar
diagnoses chololith.
7. The sixth bone of chest vertebra
diagnoses nephropathy.
8. The third bone of waist vertebra
diagnoses constipation and back
pain.
9. The fifth bone of waist vertebra
diagnoses hemorhoid.
1. The first bone of neck vertebra diagnoses
headache.
2.The third bone of neck vertebra diagnoses
hard of hearing.
3. The fifth bone of neck vertebra diagnoses
bronchus.
4. The second bone of chest vertebra
diagnoses cardiopathy.
5. The fourth bone of chest vertebra diagnoses
liver disease and tummy bug. 10. hemorrhoids, anus,
enhance physiology.
DR-XR 955S DR-XR 955S
DR-XR 955S - USM/22
This document is copyrighted by Dr.Care International Inc. This document is copyrighted by Dr.Care International Inc.

7
STANDARD FUNCTIONS
1.Negative oxygen ion function (button on left upper arm).
·Innovative negative oxygen ionizer design on head part, it can emit negative
oxygen ion ceaseless.
·By the national infrared and industrial electric products quality supervision and
inspection center verification, its negative oxygen ion concentrations up to 240
thousand /cm3, equal to forest or waterfall.
·Negative oxygen ion can reduce PM 2.5 optimize room air.
2.Magnet therapy function
·Place 8 natural energy magnet in calf air bags.
·By the national infrared and industrial electric products quality supervision and
inspection center verification, the surface of the magnetic intensity is 73mT,
according with the best protection strength of national standard “40-110mT”.
3.3D Digital Audio
·With 3D digital audio equipment on each side of the upper armrest, connect with
cell phone music to play through, you can enjoy perfect fusion of music and
massage when relaxing.
Negative oxygen
ion function
Magnet
therapy function
3D Digital Audio
WARNING
With safety switch in the power source box,
if any heavy weights on the box cover, the
backrest lay down function will be stopped,
avoiding accident crush injuries when the
backrest down.
34
ILLUSTRATION
Zone Therapy Charts By Symptoms
Every Vertebra is related with the health, for example:
Headache-Insomnia Shoulder Nerve Problem Knee Pain
Heart Problem Diabetes Liver Problem Kidney Problem
Rheumatism Arthritis Back Pain Sciatica
DR-XR 955S DR-XR 955S
DR-XR 955S - USM/22
This document is copyrighted by Dr.Care International Inc. This document is copyrighted by Dr.Care International Inc.

8
OPERATION GUIDE
DR-XR 955
DR-XR 955
A7
A6
A5
A4
A1
A0
A2
A3
33
SAFETY INTRODUCTION
4. Suggested per usage time is 15 minutes. Suggested per usage
time on a particular body part is 5 minutes.
5. Do not use the machine if the centre of the upholstery is torn.
Remove the AC plug from the electrical outlet immediately. Continu-
ous usage of the chair in this condition may cause injury to the user
or may lead to electric shock.
D. Assemble and repair of the chair
1. Do not disassemble the back cover of chair to avoid electrical shock.
2. The chair must only be serviced or repaired by Dr.Care Service Centre.
You must not disassemble or repair it by yourself.
3. Do not try to replace the machinery parts by non-Dr.Care provided spare parts
E. Things to take note on power plug and cord
1. Check the voltage corresponds with the specifications indicated for the chair. (only
for alternative current)
2. Do not disconnect the AC plug from electrical outlet roughly.
3. Do not connect or disconnect the AC plug from the electrical outlet with wet hands.
It may cause electrical shock or machine malfunction.
4. When disconnecting the AC plug, pull it out by holding on the plug, not pulling on
the cord.
5. Always switch off the power switch after operation and remove the power plug from
outlet.
6. Make sure the power plug is plug-in to outlet properly to avoid electrical shock.
7. Do not move the machine by pulling power cord.
8. Do not place the AC cord under the chair as it may damage the cord and may cause
fire or electrical shock.
9. Do not operate the chair or tamper with a damage cord or electrical plug. Contact
Dr.Care Service Centre for inspection. Use only attachments recommended by
Dr.Care.
Do not use the chair if the electrical outlet is excessively loose.
10. Use the well-grounding power supply to suit the chair.
DR-XR 955S DR-XR 955S
DR-XR 955S - USM/22
This document is copyrighted by Dr.Care International Inc. This document is copyrighted by Dr.Care International Inc.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Dr.Care Massaggiatore


















