Dynamic SpeedCop 2000 Manuale utente

Dynamic Technology Inc.
www.dynamictek.com
User Manual
FM Wireless Home Security
Alarm System
-SpeedCopTM 2000-
User Manual
FM Wireless Home Security
Alarm System
-SpeedCopTM 2000-

Index SpeedCopTM 2000
1
Standard Scope of Supply 2
Option 3
Layout -Front 4
Siren ON/OFF 20
Layout -Rear 6
Input(Overall) 21
Layout
Arming & Disarming 22
Operating flow 8Special Function
Installation Guide Bypass & Delay Time 23
Order of installation 9Chime Function 24
Power and Sensors 10 ARS Structure
Main Body, PIR/Door Sensors 11 Remote Control 25
Input Remote Control Code 26
Remote Controller 13
Guide of emergency meeting 27
Sensors 14
Power & Tel.Line cut off 28
Telephone Number 15
Sensor Feature
Emergency Call 16
PIR Sensor & Remote Controller 29
Password 17
RF Transmitter & Door Sensor 30
WARNING Notice: Please Read Carefully 31
Exit 19
Description Page(s) Description Page(s)
Attention & Request 12
Voice Recording 18
Dynamic Technology Inc.

2
Dynamic Technology Inc.
ITEM Appearance Specification
Division
Main Body
Power Supply Unit : DC9V Battery, 600mA
Power Consumption : Disarms(150mA), Arms(300mA)
Max. Sensor No. : 7 Wireless + 2 Wire
Max. Remote control No. : 7 units
Max. recording No. of Telephone : 7
Demodulation Method : Frequency Demodulation
Dimensions : 47D x 144H x 222W
B
A
S
I
C
I
T
E
M
PIR Sensor
Power : DC 9V Battery
Transmission & Reception Method : Radio Frequency
Modulation Method : Frequency Modulation
Detection Method : Passive Infrared
Angle : Vertical(45),Wide(110)
Communication Distance : Max. 1000M Detection Range : Max.30M
Dimension : 32D x 97H x 65W
Door Sensor Composition : 2 Magnetic Bars + 1 RF Transmitter
Detection Method : Magnetic
Remote
controller
Composition : 2 Buttons(ON + OFF)
Communication Method : Radio Frequency(FM Wave)
Utility Range : 50M Dimensions : 30mm x 11mmx55mm
Battery Power : DC 12V(A23 Alkaline Battery)
Adapter Power supply unit to main body at DC 9V
A
C
C
E
S
S
O
R
Y
T -Hanger When the main body is hanging on the wall
Warning Decals Sticking an invasion route for warning
Battery Supply ; the power to PIR sensor & RF transmitter
User Manual Utility Guide for SpeedCop2000
Phone cable Connector between the main body and local telephone
Standard Scope of Supply SpeedCopTM 2000

Gas Detector Gas Controller Gas Shut off Devise
Detection Method : Contact Combustion
Response Speed: Within 20 Sec.
Detects LNG & LPG, Butane/Methane Gas
Power : AV 220V, 50/60Hz
Power Consumption : 2.7W
Dimensions : 46D x 116H x 66W
Power : AV 110/220V(60Hz)
Power Consumption : 1.3W
Output Voltage : DC12V
Operating Temperature : -10 ~+40
Relative Humidity : 20 ~ 95% RH
Dimensions : 44D x 145H x 100W
Valve : Screw Type(Ball Valve)
Power : DC12V
Power Consumption : 2.5W
Shut-off Speed : 5 Sec.
Dimensions : 118D x 167H x 60W
Fire Detector RF Module Infrared Detector
Modulation : Frequency Modulation
Frequency Bandwidth : 447.275MHz
Power : DC 9V
Application Field : Gas, Door & Fire Detector
dimensions:
PIR Sensor(Ceiling style) Pet Detector Light
Detection technology : Dual Element PIR
Current Consumption : 15mA at DC 12V
Power : DC 9~16V regulated
Alarm Contact : DC 24V, 50mA
Pulse Count : Selectable 1~3
RF Immunity : 3-V/m. up to 1GHz
Current Consumption : 25mA at DC 12V
45MA at DC 16V
Voltage Requirements : DC 9-16V regulated
Alarm Contacts : DC 24V, 50mA
Temper Contacts : DC 24V, 0.1A
Power Supply : DC12V
Power Consumption : 120mA
Natural Gifts : Cover-Acrylic
Base-ABS
Dimensions : 26mm x 167mm x 96mm
Option SpeedCopTM 2000
3
Dynamic Technology Inc.

Layout -Front
1 2 3 4 5 6 7 ARM POWER
Army
DisArm
Bypass
Alarm
911 Ambulance Police
123
4 5 6
7 8 9
*0#
FrontCover
LCD(Liquid Crystal Display)
9V Alkaline Battery
Cover : Close / Open
16 17
Antenna
18
Main Body(Front)
SpeedCopTM 2000
Cut off the powerCut off the power
If the main power is cut off, the main body can operate itself by DC 9V alkaline battery continuously.
Power LED changes to a green color and other LED’s are off if the main body is supplied with power by the backup battery.
In this case, user may be confused that each sensor does not operate as the back light of LCD can not operate. But, sensors are
normally operated due to save the battery.
* You must use DC 9V alkaline battery as a backup battery
* Max. time : 6 hours
The front cover is opened
4
Dynamic Technology Inc.

1. Front Cover : Main body cover of SpeedCopTM 2000
2. Arming LED : Per each sensors Red light shows when the sensoris armed
3. Antenna : Receiving the FM signal of each sensors
4. Arming LED : Classification of Arming or Disarming
5. Power : Checking of power ON/OFF(Yellow light)
6. LCD(Liquid Crystal Display) : Showing the order or input text on the LCD
7. Arm : Arming of all the sensors.
8. Disarm : Disarming of all the sensors.
9. Bypass : Bypass the selected sensors by user’s requirement.
10. Chime : Automatic alarm notice is arming if the door is notcompletely closed and
chime bell sound when Disarming mode of the main door sensor.
11. 911(Emergency call) : Automatic call to 911 by one-touch button
12. Key : Cancellation Key
13. Ambulance : Emergency calling function to memorized hospital by one-touch button
14. Cover Open/Close : SpeedCop 2000 cover open/close
15. Police : Emergency calling function to memorized police station by one-touch button
16. Key : Enter Key
17. DC 9V battery : Spare battery when the main power is cut off
18. MIC. : Tapping or dual-communication function through MIC. from the outside
SpeedCopTM 2000
5
*
#
Layout -Front
Dynamic Technology Inc.

6
Dynamic Technology Inc.
X
X
X
X
X
X
X
X
X
X
Main Body(Rear)
Layout -Rear SpeedCopTM 2000
Rear Terminal
You can use wire sensors usually.==> You may use additional wiresensors.
1. External Lamp : Notice emergency to outside by light
2. External Siren : Notice emergency to outside by siren
3. Impact Detector : Install at windows for detecting intruder
4. Infrared Detector : Installing both sides of intruding route and detector sensing when intruder passes through this route
5. Fire Detector : Detecting fire and smoke
6. Gas Detector & Shut-off Device : Gas shut off equipment with remote controller from outside

1. Speaker : For siren, ARS comment or key tone.
2. Telephone port : Connecting port between the main body and telephone
3. Line port : Connecting port to main body from the line of the telephone office
4. T Hanger : Use when the main body is hanging on the wall
5,6. Telephone line terminal : Connecting to Line port No.3 or telephone line terminal which comes from
telephone office line
7. Output A : The first output terminal for controlling sensors or siren at the main body
8. Common : Common terminal of external output terminal A & B
9. Output B : The second output terminal for controlling sensors or siren at the main body
10. Input A : The first input terminal for transmission of signal from sensors to main body
11. Common : Common terminal of external input terminal A & B
12. Input B : The second input terminal for transmission of signal from sensors to main body
13. GND : DC 9V power ground terminal
14. DC power terminal : DC 9Vpower terminal
15. DC power terminal : DC 9Vpower terminal(for Adapter)
Layout -Rear SpeedCopTM 2000
7
Dynamic Technology Inc.

Operating Flow SpeedCopTM 2000
8
Dynamic Technology Inc.
Intruders & Emergency
Automatic Dialing to the personal Cellular Phone
or other designated destination
(7 Memorized Telephone Numbers)
Tapping and checking by sounds
from the outside
Controlling of the intruder with Siren
and arms(Option)
Call to related office or neighbor for help.
Flow
Flow-
-Chart
Chart
Flow
Flow-
-Chart
Chart
Intruders
Sensor #1 Sensor #2 Sensor #7
FM TransmissionFM Transmission
(1 Km Direct Distance)(1 Km Direct Distance)
Emergency CallEmergency Call
PCS
C/Phone
Neighbors
Company
Related
Office
Memorized 7
Phone No.
#1
PSTN : Local Telephone
Intruder
Intruder
Intruder
Intruder

1. Check the position of Main body & Sensors1. Check the position of Main body & Sensors
-- Considering the position of main power & telephone lineConsidering the position of main power & telephone line
2. Unpacking the SpeedCop 20002. Unpacking the SpeedCop 2000
3. Connecting the telephone line and the power to the Main Body3. Connecting the telephone line and the power to the Main Body
-- Main Power : for DC 9V(adapter)Main Power : for DC 9V(adapter)
4. Input the telephone numbers, set up sensors and remote4. Input the telephone numbers, set up sensors and remote
controller.controller.
5. Connecting each sensors to input & output terminal5. Connecting each sensors to input & output terminal
-- ex : Gas detector, siren, wire sensor, etc.(Picture 2)ex : Gas detector, siren, wire sensor, etc.(Picture 2)
6. Re6. Re--checking input result and test operationchecking input result and test operation
7. Fixing and hanging main body & each sensors7. Fixing and hanging main body & each sensors
Installation Completed
Installation Completed
Installation Guide-Order of installation SpeedCopTM 2000
9
Dynamic Technology Inc.
Indice
Manuali Sistema di sicurezza popolari di altre marche

EDM
EDM Solution 6+6 Wireless-AE Manuale utente

Highway Safety Group
Highway Safety Group EA401 Manuale utente

Siren
Siren LED GSM Manuale utente

Detection Systems
Detection Systems 7090i Istruzioni per il montaggio

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuale utente

Siemens
Siemens FDM273 Manuale utente











