PROVIDER OF LIFE STYLE & INDUSTRIAL SCALESSurvey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110, Fax : + 91 - 20 - 30418126. Email : sales@egkantawalla.comINDEX1. Gratitude................................................... 2. Unpacking .......................................................3. Installation Procedure .....................................2. Technical Data of Scale............................. 3. Connections ........................................... 4. Key Operation ......................................... 5. Scale Functions ................................................ 6. User Parameter Setting Mode ......................... 7. Maintenance and Attention ............................ Warranty Card ................................................. Other Products ................................................ Sr. NoChapterPage No.

Chapter 1. Gratitude1Thank you for purchasing an EAGLE ECON series Digital Weighing Scale. The ECON series models are high performance and economic digital Weighing Scales that we confidently recommend based on over 97 years of Weighing Scale manufacturer. While these models are of course capable of fast and accurate weighing, the ECON Series models all use the High Precision Load Cells and highly reliable electronic boards that EAGLE started using for Digital Weighing Scale in 1976, and the ECON Series models use our unique, newly developed and robust product range, improving the reliability of the scales still further.The new ECON series Scales also feature operation keys for four directions, improving convenience and making the scales easier to use. ECON Series Scales have Counting Function, Liter Conversion, Password Protected unit conversion, Weight Accumulation Function up to 999999, Selectable display speed, Auto Tare, Peak Hold, Auto Sleep, Zero Locking counts and Stable time setting. These Scales also feature a variety of other functions that make it more convenient for customers to use them for their own applications, including the PC communication function, which enables measuring results to be transferred to a PC without installing any software. To ensure that you can make full use of the performance and functions of your ECON series balance, read this instruction manual carefully and use the scale correctly in accordance with the directions in the manual. When you have finished reading the manual, keep it in a safe place together with the scale so that you can refer to it at any time.For information on the following points, please contact our EAGLE representative.Product warranty and After Sales servicePROVIDER OF LIFE STYLE & INDUSTRIAL SCALESSurvey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110, Fax : + 91 - 20 - 30418126. Email : sales@egkantawalla.com

2Chapter 4. Technical Data Of Scale 1. Series - ECON Series 2. Serial communication interface - RS-232 signal 3. Transmission distance - <20m 4. Power supply - AC240V;50Hz (-2%~+2%) 5. Operating temperature - (-10°C to 50°C) 6. Relative humidity - ≤85%RH 7. Internal Resolution - 20,00,000Load Cell Wiring Pin 1 >>>>> Supply + (Red) Pin 2 >>>>> Supply - (Black) Pin 3 >>>>> Signal + (Green) Pin 4 >>>>> Signal - (White) Pin 5 >>>>> ShieldRS-232 Cable WiringDb9 Pin Female Connector – Scale End DB9 Pin Female Connector – Scale End(GND) Pin 5 >>>>> Pin 5 (GND)(Tx) Pin 3 >>>>> Pin 2 (Rx)(Rx) Pin 2 >>>>> Pin 3 (Tx) Baud Rate : 1200, 2400, 4800 and 9600Data Bits : 8Parity Bit : NoneStop Bit : 1Chapter 5. ConnectionsPROVIDER OF LIFE STYLE & INDUSTRIAL SCALESSurvey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110, Fax : + 91 - 20 - 30418126. Email : sales@egkantawalla.com12345

3Chapter 6. Key Operations1. Zero Key: Used to zero the weight on scale. It operates up to 4% of scale capacity only; as per Weights and Measure law. The key is also used as left increment key.2. Tare Key: Used to Tare the weight. The key is also used as decrement key.3. M+/MR : Used to accumulate the data, Recall the acummulated data also used as Enter/Selection key4. Func Key: Used to go into counting mode. The key is used as enter key.5. N/G Key :Used to toggle the displayed weight between Net and Gross weight. The key is also used as Left Shift key.Chapter 7. Scale Functions1. Counting Function: Using the counting function user can count the similar items on the scale. The scale have 6 fixed sample sizes they are 10, 20, 50, 100, 200 and 500 pieces. When the [Func] Key is pressed the display alternates between the following:- 1. S 0 – this for selection of going back to weight mode. 2. S cnt – this for selection of going back to count mode using the last sample weight. 3. S 10 – this for selection of sample size of 10 pieces. 4. S 20 – this for selection of sample size of 20 pieces. 5. S 50 – this for selection of sample size of 50 pieces. 6. S 100 – this for selection of sample size of 100 pieces. 7. S 200 – this for selection of sample size of 200 pieces. 8. S 500 – this for selection of sample size of 500 pieces.PROVIDER OF LIFE STYLE & INDUSTRIAL SCALESSurvey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110, Fax : + 91 - 20 - 30418126. Email : sales@egkantawalla.com

4Enter in to Counting Mode:1. Place the counted samples on the pan.2. Press [Func] key the display will show [S 0]. Select the options listed above. (If the samples kept on the pan are 10nos)3. Press [Func] key again to change the option and select [S 10]4. Press [M] key for the confirmation.5. Repeated the procedure from 1 to 4 for all the other samples.After pressing the conformation key the scale will calculate the unit weight and go in to Counting Mode. now the display will show the number of samples on the scale as 10.To Recall Previous Counting Mode:1. Press [Func] key the display will show [S 0].2. Press [Func] key again to change the option and select [S Cnt]3. Press [M] key for the confirmation. After pressing confirmation key the scale will recall the previously calculated Unit Weight.To Escape form Counting Mode:1. Press [Func] key the display will show [S 0].2. Press [M] key again to escape from counting mode to weighing mode.If the scale is restarted in counting mode it will by default start in counting mode.PROVIDER OF LIFE STYLE & INDUSTRIAL SCALESSurvey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110, Fax : + 91 - 20 - 30418126. Email : sales@egkantawalla.com

5PROVIDER OF LIFE STYLE & INDUSTRIAL SCALESSurvey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110, Fax : + 91 - 20 - 30418126. Email : sales@egkantawalla.com2. Weight Accumulation: When scale is in weighing mode press [M] key the accumulation of displayed weight is done. On releasing the [M] key the display will show [Add xxx](Add xxx where xxx = number of times the weight has been accumulated) for 1sec and then accumulated weight for 2sec then scale will come back to weighing mode.To view the accumulated weight:Press [M] key in zero mode (When no weight on the scale i.e. 0.000) display will show [Add xxx] for 1sec and then flash accumulated weight three times and then back to weighing mode.To clear the accumulated weight:Press [M] key in zero mode sale display will show [Add xxx] for 1 sec and then flashes accumulated weight. During the flashing if [ZERO] key is pressed scale will clear both accumulate weight and number of times added count.The accumulation will not happen when weight is in negative. This time scale will show [Err-or].When accumulating current weight which will cause the value of the accumulated weight to go over 999999 then at such time the scale will display [tot-of] and show accumulated value without accumulating current weight.When accumulating current weight which will cause the number of times weight accumulated to exceed beyond 999 then at such time the scale will display [Add-of] and show accumulated value without accumulating current weight.

6PROVIDER OF LIFE STYLE & INDUSTRIAL SCALESSurvey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110, Fax : + 91 - 20 - 30418126. Email : sales@egkantawalla.com1. Display Speed Selection 2. Data format on RS-232 3. Baud Rate Selection 4. RS-232 output data d-SPd SPd-1 SPd-2SPd-3SPd-4SPd-5tr-232 tr-01 tr-02 : tr-13 b-rAt b-1200b-2400b-4800b-9600OUt-Nd-OUt OUt-GOUt-t
TARE
ZERO
TARE
ZERO
TARE
ZERO
TARE
ZERO
TARE
ZERO
TARE
ZERO
TARE
ZERO
TARE
ZERO
M M M M Chapter 8. User Parameter Setting ModeIn weighing mode, keep [FUNC] key pressed for 5 sec, it will enter operator setting mode, press [M] to choose the mode, press [TARE] to move forward and press [ZERO] to move reverse the parameter. Pressing the [FUNC] key will make you escape to previous menu or stage. The description of parameters are as follows:

7PROVIDER OF LIFE STYLE & INDUSTRIAL SCALESSurvey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110, Fax : + 91 - 20 - 30418126. Email : sales@egkantawalla.com6.7.8.9.11.5.10. Power ON Zero functionPeak Hold FunctionAuto Sleep TimeZero Lock CountsStable TimeAuto Tare functionStable Time
Pn-ZroZro-yZro-n P-HLd HLd-n HLd-y A-SLP SLP-00 to 99 Zr-Loc Loc-00 to 99 Stb-t Stb-2 Stb-1 Stb-3
TARE
ZERO
TARE
ZERO
TARE
ZERO
TARE
ZERO
TARE
ZERO
TARE
ZERO
TARE
ZERO
Back to 1From 10
TARE
ZERO
TARE
M MM M M A-trE trE-y trE-n
TARE
ZERO
TARE
ZERO
M HLd-PMLr-FAt 0.974
TARE
ZERO

9PROVIDER OF LIFE STYLE & INDUSTRIAL SCALESSurvey No. 28/1, Damodar Nagar, Kharadi, Pune - 411014. Tel : + 91 - 20 30418100 / 110, Fax : + 91 - 20 - 30418126. Email : sales@egkantawalla.com1. Display Speed Selection [d-SPd]-The scale have 5 different display update speeds. SPd-1 is the fastest and SPd-5 is the slowest speed.To set Display Speed:a. Enter in to User Parameter Setting Mode showing Display Speed Selectionb. Press [M] key to select display speedc. Scale always shows previously set display speed. Using [TARE] & [ZERO] key to select SPd-1 to SPd-5d. Press [M] key to confirm the selectione. Use [FUNC] key to escape from selectionNote: Pressing [FUNC] key it will back to display Speed Selection. If without selection escaped out then scale will work on previously set speed.2. RS-232 Data Format [tr-232]- The scale have 13 different Data formats the way explained below.Three modes of transmission and four formats of data explained in following table. The command from computer will be Z, T and $ character.Z Command – The scale should get ZEROD.T Command – The scale should get TARED.$ Command – The scale should send the weight data to PCTransmission ModesFormatsWeightSign+WeightWeight+UnitSign+Weight+UnitOn Pressing COUNT Key=002.000[tr-01]=+002.000[tr-02]=002.000kg[tr-03]=+002.000kg[tr-04]Continuous Transmission=002.000[tr-05]=+002.000[tr-06]=002.000kg[tr-07]=+002.000kg[tr-08]On command ”$” from computer=002.000[tr-09]=+002.000[tr-10]=002.000kg[tr-11]=+002.000kg[tr-12]