EasyDetek EDC212S Manuale utente

EDC212S
Address: Room 402, Building B, Hangcheng Industrial Zone, Chentian, Xixiang Street, Baoan District, Shenzhen
Phone: 0755-27788421 Website: http://www.easydetek.com
Shenzhen EasyDetek Technology Co.,Ltd
- 1 -
EDC212S-A
EDC212S-B
EDC212S-C

EDC212S
Address: Room 402, Building B, Hangcheng Industrial Zone, Chentian, Xixiang Street, Baoan District, Shenzhen
Phone: 0755-27788421 Website: http://www.easydetek.com
Shenzhen EasyDetek Technology Co.,Ltd
- 2 -
product description
■The shell is made of flame-retardant materials, with a fire rating of V-0;
■Patented antenna design, super anti-interference; digital radar chip, good consistency;
■Not affected by temperature, humidity, air flow, dust, noise, brightness, etc.;
■Meet the requirements of environmental protection.
Electrical properties
Transmit frequency 5.8GHz±75MHz
Load power <600W @100V-240V
Operating Voltage AC 100-240V
3db beam angle 93°(XZ plane) 99°(YZ plane)
Transmission power consumption 1mW
Standby power consumption <0.5W
Sensing distance 5-6m
Power supply frequency 50Hz & 60Hz
Delay time EDC212S-A/EDC212S-B(5s,1min,3min,5min) EDC212S-C(10s,30s,1min)
Photosensitive threshold EDC212S-A/EDC212S-B(25Lux,Disable)EDC212S-C(15Lux,30Lux,Disable)
Antenna gain 3.6dB
life 50000h
Operating temperature -20...﹢70℃
storage temperature -20...﹢105℃
Remarks: 1. The test distance range is based on the module hanging height 3m, indoor environment test, the tester's
height is 170cm, the weight is 65-75kg, and the walking speed is 1m/s (2 steps per second). Different installation
scenarios may cause range changes. Subject to actual test;
2. Due to the spectral characteristics of the photosensitive device, the threshold is uniformly tested under natural light
conditions;
3. The delay time can be customized according to customer needs, with a delay tolerance of ±10%;
4. The switching speed interval cannot be less than 2s each time.

EDC212S
Address: Room 402, Building B, Hangcheng Industrial Zone, Chentian, Xixiang Street, Baoan District, Shenzhen
Phone: 0755-27788421 Website: http://www.easydetek.com
Shenzhen EasyDetek Technology Co.,Ltd
- 3 -
Typical application products
Ceiling light Three anti-light Moisture-proof lamp
*The above are typical application products, which can be expanded to more products
Product information
Model
Function description
EDC212S-A
4-digit dialing code for forward installation (same side as antenna)
EDC212S-B
4 digit dialing code installed backwards (on the opposite side of the antenna)
EDC212S-C
No dial code, infrared remote control adjustment (same side as antenna)
DIP switch settings
First place: Sensing distance setting
1
100%
ON
50%
-
According to different applications, the sensing distance can be adjusted by the code switch to set 100%, 50%
The second and third digits: delay time setting
2
3
5s
ON
ON
1min
ON
-
3min
-
0N
5min
-
-
Delay time refers to the time that the light is on after the moving object leaves the sensing area. The gears can be set: 5s,
1min, 3min, 5min

EDC212S
Address: Room 402, Building B, Hangcheng Industrial Zone, Chentian, Xixiang Street, Baoan District, Shenzhen
Phone: 0755-27788421 Website: http://www.easydetek.com
Shenzhen EasyDetek Technology Co.,Ltd
- 4 -
Fourth place: photosensitive threshold setting
4
25Lux
ON
Disable
-
When the ambient illuminance value is lower than the set valve, an object moves in the sensing area. The stalls are:
25Lux / all day
Pin description
EDC212S-A pin
Pin
Description
L-out
Fire wire out
N-out
Zero line out
L-in
Fire wire in
N-in
Zero line in
EDC212S-B pin
Pin
Description
L-out
Fire wire out
N-out
Zero line out
L-in
Fire wire in
N-in
Zero line in

EDC212S
Address: Room 402, Building B, Hangcheng Industrial Zone, Chentian, Xixiang Street, Baoan District, Shenzhen
Phone: 0755-27788421 Website: http://www.easydetek.com
Shenzhen EasyDetek Technology Co.,Ltd
- 5 -
EDC212S-C Pin
Pin
Description
L-out
Fire wire out
N-out
Zero line out
L-in
Fire wire in
N-in
Zero line in

EDC212S
Address: Room 402, Building B, Hangcheng Industrial Zone, Chentian, Xixiang Street, Baoan District, Shenzhen
Phone: 0755-27788421 Website: http://www.easydetek.com
Shenzhen EasyDetek Technology Co.,Ltd
- 6 -
Infrared remote control settings
Product size chart
100%: 4-6m
75%: 3-4.5m
50%: 2.5-4m
25%: 1.5-2m
10s: select time 10s
30s: select time 30s
1min: select time 1min
Turn on the photosensitive function
Turn off the photosensitive function
30Lux
15Lux

EDC212S
Address: Room 402, Building B, Hangcheng Industrial Zone, Chentian, Xixiang Street, Baoan District, Shenzhen
Phone: 0755-27788421 Website: http://www.easydetek.com
Shenzhen EasyDetek Technology Co.,Ltd
- 7 -
EDC212S-A Unit: (mm)
EDC212S-B Unit: (mm)

EDC212S
Address: Room 402, Building B, Hangcheng Industrial Zone, Chentian, Xixiang Street, Baoan District, Shenzhen
Phone: 0755-27788421 Website: http://www.easydetek.com
Shenzhen EasyDetek Technology Co.,Ltd
- 8 -
EDC212S-C Unit: (mm)
Function Description
Photosensitive function is on
When the ambient light is bright enough, the light will not
automatically light up even if a moving object is detected
When the ambient light is lower than the preset
photosensitive threshold, the light will automatically light
up when the sensor detects a moving object
After the moving object leaves, the sensor will enter the
delay time when it cannot detect the moving object and
keep the light on
After the preset delay time, the light will automatically turn off

EDC212S
Address: Room 402, Building B, Hangcheng Industrial Zone, Chentian, Xixiang Street, Baoan District, Shenzhen
Phone: 0755-27788421 Website: http://www.easydetek.com
Shenzhen EasyDetek Technology Co.,Ltd
- 9 -
Photosensitive function is off
Packaging Information
Support packaging:Blister packaging Bubble bag packaging PE bag packaging
No moving objects can be detected, and the lamp goes
out
When the sensor detects a moving object, the light
automatically lights up at 100% brightness and enters the
set delay time
After the delay time, when the sensor cannot detect
any moving objects, the lamp will be off

EDC212S
Address: Room 402, Building B, Hangcheng Industrial Zone, Chentian, Xixiang Street, Baoan District, Shenzhen
Phone: 0755-27788421 Website: http://www.easydetek.com
Shenzhen EasyDetek Technology Co.,Ltd
- 10 -
Detection diagram (distance can be adjusted according to actual application)
Detection sensitivity gear:
Ceiling installation diagram
Precautions
1. When installing the product, the antenna board is required to maintain a certain height from the metal plane. It is
recommended that the antenna board be kept at a distance of 5-12mm from the metal plane. It should not be close to or
touch the metal plane, otherwise the product may not work properly!
2. The product has a better penetration effect on plastic and wood. At the same time, avoid metal shielding in front of
the antenna, which will reflect microwaves and affect the actual sensing effect;
3. Installing glass in front of the antenna will cause electromagnetic wave reflection and penetration attenuation, which
will reduce the sensing distance of the sensor; installing ceramics in front of the antenna will also produce penetration
attenuation, the greater the thickness, the more serious the attenuation;
4. Please use a power supply with a small ripple for power supply, especially low-frequency ripples are likely to interfere
with the operation of the sensor and cause false alarms. The recommended power supply capacitor is 470 uF; it is
recommended that the power supply ripple be guaranteed within 100mV, and the ripple of 50mV is better;
5. The signal output of the sensor, the load current capacity is weak, it may not be able to directly drive the back-end
equipment.
6. When multiple sensors are used in the same site, the spacing should be greater than 0.5m. It is recommended that the
product installation spacing be greater than 1.5m. Too close installation distance may cause false alarms in individual
cycles;
7. Avoid high current circuit coverage on the antenna surface. The electromagnetic field generated by the circuit loop will
Questo manuale è adatto per i seguenti modelli
3
Indice