Ebyte ECAN-401 Manuale utente

Chengdu Ebyte Electronic Technology Co.,Ltd. ECAN-401 User Manual
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.
2
CONTENTS
1. PRODUCT OVERVIEW......................................................................................................................................................................... 4
1.1 BRIEF INTRODUCTION..................................................................................................................................................................... 4
1.2 FEATURE.............................................................................................................................................................................................. 4
1.3 APPLICATION...................................................................................................................................................................................... 5
2. PRODUCT SPECIFICATIONS AND CHARACTERISTICS................................................................................................................6
2.1 BASIC PARAMETERS.......................................................................................................................................................6
2.2 FACTORY DEFAULT PARAMETERS................................................................................................................................... 6
3. HARDWARE PARAMETER DESIGN INTRODUCTION................................................................................................................... 7
3.1 DESIGN INTRODUCTION................................................................................................................................................. 7
3.2 DIMENSIONS.................................................................................................................................................................. 8
3.3 CONNECTION METHOD...................................................................................................................................................9
3.3.1 RS485 connection method......................................................................................................................................
9
3.3.2 RS422 connection method......................................................................................................................................
9
3.3.3 RS232 connection method....................................................................................................................................
10
3.3.4 CAN connection method.......................................................................................................................................
10
4. MODE DESCRIPTION......................................................................................................................................................................... 11
4.1 DATA CONVERSION METHOD........................................................................................................................................11
4.1.1 Transparent conversion mode..............................................................................................................................
11
4.1.2 Transparent transmission with logo mode...........................................................................................................
14
4.1.3 Protocol mode......................................................................................................................................................
16
4.1.4 Modbus mode.......................................................................................................................................................
18
4.1.5 Custom protocol mode..........................................................................................................................................
20
5. AT COMMAND.....................................................................................................................................................................................23
5.1 ENTER AT COMMAND.................................................................................................................................................. 23
5.2 EXIT AT COMMAND..................................................................................................................................................... 23
5.3 QUERY VERSION.......................................................................................................................................................... 24
5.4 RESTORE DEFAULT PARAMETERS................................................................................................................................. 24
5.5 ECHO SETTINGS........................................................................................................................................................... 24
5.6 SERIAL PORT PARAMETERS.......................................................................................................................................... 25
5.7 SETTING/QUERYING CAN INFORMATION.................................................................................................................... 26
5.8 SETTING/QUERYING MODULE CONVERSION MODE....................................................................................................26
5.9 SET/QUERY THE FILTERING MODE OF THE CAN BUS...................................................................................................27
5.10 SET/QUERY FRAME HEADER AND FRAME END DATA..................................................................................................27
5.11 SETTING/QUERYING IDENTIFICATION PARAMETERS.................................................................................................. 27
5.12 SETTING/QUERYING IDENTIFICATION PARAMETERS..................................................................................................28
5.13 SET/QUERY TRANSMISSION DIRECTION......................................................................................................................28
5.14 SETTING/QUERYING FILTER PARAMETERS................................................................................................................ 29
5.15 DELETE THE FILTER PARAMETERS THAT HAVE BEEN SET........................................................................................... 29
6. REVISION HISTORY........................................................................................................................................................................... 30
ABOUT US................................................................................................................................................................................................30

Chengdu Ebyte Electronic Technology Co.,Ltd. ECAN-401 User Manual
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.
3
Disclaimer
EBYTE reserves all rights to this document and the information contained herein.
Products, names, logos and designs described herein may in whole or in part be
subject to intellectual property rights. Reproduction, use, modification or disclosure to
third parties of this document or any part thereof without the express permission of
EBYTE is strictly prohibited.
The information contained herein is provided “as is” and EBYTE assumes no
liability for the use of the information. No warranty, either express or implied, is given,
including but not limited, with respect to the accuracy, correctness, reliability and
fitness for a particular purpose of the information. This document may be revised by
EBYTE at any time. For most recent documents, visit www.ebyte.com.
Note:
The contents of this manual are subject to change due to product version upgrades
or other reasons.Chengdu Ebyte Electronic Technology Co.,Ltd. reserves the right to
make changes to the contents of this manual without notice or suggestion.This manual
serves only as a user guide and Chengdu Ebyte Electronic Technology Co.,Ltd.
endeavours to provide accurate information in this manual, but Chengdu Billionaire
Electronics Co., Ltd. does not ensure that the contents are completely error-free and
that all statements, information and suggestions in this manual do not constitute any
express or implied warranty.

Chengdu Ebyte Electronic Technology Co.,Ltd. ECAN-401 User Manual
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.
4
1. Product Overview
1.1 Brief Introduction
ECAN-401 is a small intelligent protocol conversion product independently developed by Chengdu Ebyte
Electronic Technology Co., Ltd. The product uses 8V ~28V wide voltage power supply,
integrates 1 CAN-BUS interface, 1 RS485 interface, 1 RS232 interface and 1 RS422
interface, which can realize two-way conversion between CAN and RS485/RS232/RS422
different protocol data. The product supports serial AT command configuration and host
computer configuration device parameters and working modes, and supports five data
conversion modes including transparent conversion, transparent conversion with logo,
protocol conversion, Modbus RTU conversion, and user-defined (user). At the same time,
ECAN-401 intelligent protocol converter has the characteristics of small size, easy
installation, and high protection isolation design for CAN interface. It has a very high cost performance in the
development of CAN-BUS products and data analysis applications. It is an engineering application and project
debugging. And reliable assistants for product development. .
1.2 Feature
Bidirectional conversion between CAN and RS485/RS232/RS422 different protocol data;
Support transparent conversion, transparent conversion with logo, protocol conversion, Modbus RTU conversion,
custom protocol conversion;
Support RS485/RS232/RS422 interface parameter configuration;
Support AT command parameter configuration;
Support the configuration of upper computer parameters;
Support AT command and host computer to restore factory settings;
With power indicator, status indicator and other status indicators;
Multi-master and multi-slave function;
CAN interface adopts high protection isolation design.

Chengdu Ebyte Electronic Technology Co.,Ltd. ECAN-401 User Manual
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.
5
1.3 Application
CAN-BUS network such as industrial control
Networking of automobiles and railway equipment
Security and fire protection network
Underground remote communication
Public address system
Parking equipment control
Smart home, smart building

Chengdu Ebyte Electronic Technology Co., Ltd. E78-900M22S User manual
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
6
2. Product specifications and characteristics
2.1 Basic parameters
Main parameters
Specification
voltage
8V~28V, 12V or 24V power supply is recommended
Working current
18mA@12V (standby)
Operating temperature
-40℃~85℃, industrial grade
Interface Type
RS485/RS422/CAN: 5.08 terminal block, crimping method
RS232: DB9 terminal
2.2 Factory default parameters
RS485/RS232/RS422
Serial port baud rate
115200 bps
Parity check
No
Data bit
8
Stop bit
1
Flow Control
shut
CAN
CAN baud rate
100K bps
CAN ID
0x00000000
Default
working mode
Transparent transmission
Receive all data types

Chengdu Ebyte Electronic Technology Co.,Ltd. ECAN-401 User Manual
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.
7
3. Hardware parameter design introduction
3.1 Design introduction
No
Name
Pin usage
1
RS232
DB9 communication terminal
2
PWR
Power Indicator
3
CAN_ERR
Error light
4
CAN_DATA
Data light
5
RX
Serial port receiving indicator
6
TX
Serial port sending indicator
7
V+
Power supply, default 8-28V (standard 5V version can be customized),
12V/24V is recommended
8
V-
Power ground
9
GND
RS485/RS422 common terminal, connect to the GND of other equipment
RS485/RS422 equipment
10
T+(A)
RS422 bus data T+/RS485 bus data A
11
T-(B)
RS422 bus data T-/RS485 bus data B
12
R+
RS422 bus data R+
13
R-
RS422 bus data R-
14
CAN_G
CAN ground
15
CAN_L
CAN communication interface

Chengdu Ebyte Electronic Technology Co.,Ltd. ECAN-401 User Manual
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.
10
3.3.3 RS232 connection method
3.3.4 CAN connection method
The linear topology is the most commonly used in the CAN bus wiring specification. That is, the two lines of the main
trunk branch out branch lines to each node. Both ends of the backbone are equipped with suitable terminal resistors to
achieve impedance matching (usually 120 ohms within 2km).
Indice
Altri manuali Ebyte Convertitore multimediale