2. Checks at Order Stage
GENERAL INFORMATION
DATE.
TIME .
CONTACT(S).
COMPANY.
ADDRESS.
PHONE NO.
FAX NO.
________________________________________
CONTRACT INFORMATION
CUSTOMER REF. No.
CONFIDENTIAL? JOB NAME.
DELIVERY AREA.
SPECIFICATION PAGES.
OTHER STANDARDS REFERRED TO IN SPECI.
DRAWING NO's.
SCHEDULE REFERENCE.
OTHER CUSTOMER DOCUMENTS.
________________________________________
UNIT INFORMATION
ITEM No.
AREA REF.
No. OFF.
SUPPLY/EXTRACT.
INT/EXT/ROOF/FITTED WORKS OR SITE.
PART/HORIZ.
PART/VERT.
CONFIGURATION/SKETCH .
25mm - 50mm PANELS.
________________________________________
EXTERNAL SYSTEM RESISTANCE.
DEPRESSION AT UNIT INLET.
POSITIVE AT FAN DISCHARGE.
PRESSURISED SEP/MIX BOX/PLENUM.
DIFFUSION/BLANKING SCREEN?
INLET POSITION.
DISCHARGE POSITION.
ONE-TWO-DUPLEX-TRIPLEX.
DIDW - SISW.
FC/BC.
BD/DD.
RAFT/RIGID.
I.G V. + CONTROLLER.
NRD's ONE. TWO.
GUARDS:-
INLET/EYES/DISCH/DRIVE.
________________________________________
DRIVES
MOTORS INT/EXT.
DUTY/IDLING.
PULLIES/BELTS/IN/OUT/AIR STREAM.
1 SPEED/2 SPEED/VARIABLE SPEED.
SPD CHANGE INTERLOCK WITH EAHB.
POLE CHANGE/DUAL WOUND.
ELECTROMAGNETIC CLUTCH (TASC)
SWITCHED RELUCTANCE.
INVERTER.
DOL/SD.
ST' D/FLF!
ELEC SUPPLY.
FLOOR GRID.
LIFTING BEAMS.
________________________________________
FILTERS
PRESTl.STll.
AFTER ST.l .11.111.
TO EXTRACT HEAT RECOVERY.
GREASE TO KITCHEN EXTRACT.
TYPE.
EFFICIENCY BY WEIGHT.
EFFICIENCY SPOT DUST.
RETENTIVITY (ACT.CARBON).
BS.ASHRAE.EUROVENT.
WITHDRAWAL- SIDE/US/DS/T/B.
FITTED MANOMETER(S).
MAGNAHELIC(S).
RADIANT HEAT FROM EAHB.
________________________________________
INLETS AND DISCHARGES.
LOUVRES/FAI/DTA/STD/ACOUSTIC.
ELMTRS + DRAIN HIGH VELOCITY
FAN DISCHARGE 45
º
SPIGOT + MESH.
________________________________________
SEPARATlON/MlXlNG BOXES/VCD'S
INT/EXT DAMPERS.
FAI/RC/DTA POSITION.
OPP/PAR/MAN/MOTOR/BELIMO.
VOLUME CONTROL
100%/ZONE/F & BP/LOCATION.
INT/EXT.
OPP/PAR/MAN/MOTOR .
CONSTRUCTION GSS.
________________________________________
HEATING/COOLING
HEAT RECOVERY
HEAT REJECTION
DEHUMIDIFYING
HUMIDIFYING
POSITION/TYPE.
DRAW THROUGH/BLOW THROUGH.
VOLUME m
3
/s.
AIR ON CWB/DB/kg/kg.
AIR OFF CWB/DB/kg/kg.
SWEATING INS FRAME.
DX + CONST OFF = FREEZE.
HUMID POSN ADJ SURFACES - WETTING.
CLEAR DISTANCE DOWNSTREAM.
GAS HEATER.CONDENSATION - BYPASS.
COMBST'N AIR INLET-FLUE OUTUT. POSN.
LOAD/EFF/OUTPUT.
STEPS/INTERLACED/FACE .
MEDIUM TYPE.
FLOW/RETURN ºC.
EVAP. TEMP ºC.
PRESSURE - BAR/Kpa.
GLYCOL %.
OUTSIDE AMBIENT,
COND.TEMP C.
ELEC SUPPLY.
EAHB MIN AIR FLOW SPEED.
EAHB BALANCED ACROSS 3PH SUPPLY.
INTERLOCK WITH VAR. SP. FAN.
CONSTRUCTION.
PLATES/TUBES/FINS.
ELEMENTS/BURNER/INFILL.
FINISH:- SELF/VINYL/ET.
FREE COOLING & MECHANICAL TOP UP.
AIR ENTERING AT 90º TO COIL FACE.
FACE VELOCITY PROFILE.
CONDENSATE DRAIN PROVISION - HEIGHT
________________________________________
PLENUMS
LOCATION/FUNCTION .
DIFFUSER/SPACER/ACCESS.
90º/HORZ/VERT.
TO/FROM:- ABOVE/BELOW/LHS/RHS.
HINGED/LIFT OFF.
TOOL OP/HANDLES/LOCK TO ONE HANDLE.
VIEWPORT(S).
BULKHEAD LIGHT(S) EXT SWITCH.
WIRING BY OTHERS.
FLOOR GRIDS.
________________________________________
INLET/DISCHARGES
FROM:- ABOVE/BELOW/LHS/RHS/FACE.
LOUVRE/SPIGOT.
STACK & COWL.
90º + SCTV.
GRlLLE/SD/DD/NV/OBD's.
CONSTRUCTION.
FINISH.
________________________________________
VIBRATION ISOLATORS
INT/EXT.
EFF REQUIRED %.
RUBBER IN SHEAR/STEEL SPRING.
JACKING.
SELF LEVELLING.
FIXED/LOOSE.
________________________________________
FLEXIBLES
ISOLATING/FAN RAFT/FAN SECTION.
COMPUTE UNIT/PIPE CONNECTIONS.
ATTENUATING.
FLAME RESISTANT.
CONSTRUCTION.
FINISH.
________________________________________
ATTENUATORS
EXTRACT/ATMOS/ROOM SIDE/ZONE.
SUPPLY/ATMOS/ROOM SIDE/ZONE.
TO ACHIEVE NR IN/AT.
UNIT/DUCT MOUNTED.
STRAIGHT /90 + SCTV.
VOLUME m
3
/s.
INLET/OUTLET PLENUM/LENGTH.
FROM/TO/ABOVE/BELOW/LHS/RHS/FACE.
FINISH.
BREAKOUT.
FLANKING .
ANCILLARIES
50 x 100 x 50 FULL PERIMETER BASE.
6MM ANODISED ALUMINIUM.
3MM GSS.
INTEGRAL LUGS.
SUPPORT LEGS.
SUPPORT STEELWORK.
SlDE/CENTRAL/SERVlCES CORRIDORS.
PIPEWORK.
CONTROLS.
WIRING.
ACCESS PLATFORMS.
________________________________________
CONSTRUCTION
FRAME/GSS/ALI/PLASTISOL.
OUTER PANELS/GSS/PLASTISOL.
INNER SKIN/GSS/PLASTISOL/ST. ST.
INSULATlON/25mm/50mm/65kg/m
3
.
________________________________________
FINISH
LOCATION EXT/INT.
ANODISED ALI.
PLASTISOL.
GSS SELF.
________________________________________
PROTECTION
POLYSTYRENE CORNERS
CLING FILM WRAF'
POLYSTYRENE BOARDS
REWRAPPED AFTER ASSEMBLY.
________________________________________
SITE COSTS
SITE SUPERVISION WORK REQUIRED.
SITE ASSEMBLY REQUIRED
SAFETY CHECKS l.E. GAS HEATERS
GUARANTEE CHECKS
l.E. ASSEMBLY STANDARDS. WEATHERING
AND SITE AIR LEAKAGE STANDARDS.
________________________________________
PROBLEMS
TRANSPORT:- LOADED VEHICLE OBSTACLE
CLEARANCE/ROUTE LOAD BEARING.
ROAD CLOSURE/STAT PERMISSIONS
ONLOADING/OFFLOADING. CRANE/FORK
LIFT-
WEIGHT/CAPACITY.
MOVING ON SITE:- ROUTE/LOADS/METHOD/
BUILDING LOAD BEARING.
MAX SIZE/WEIGHT PER PIECE FOR ACCESS
DRY STORAGE BEFORE ERECTION
BASES:- LEVEL/LOAD BRG/RELEVELLING
DEV'S
BOLTING ADJACENT SECTIONS ON SITE
l.E. HEATING & COOLING COILS.
ACCESS/MAINTENANCE/WITHDRAWAL PLANT.
SUN/WIND/RAIN/SNOW.
SALINE/ICING.
DUST/POWDER/GRIT/SOOT/SMOKE/SAND.
TALL UNITS ON PLINTHS SIDE WALKWAY?
ARE TOP ACCESS DOOR CATCHES IN
REACH?
CONTAINMENT & DRAINAGE OF LEAKS.
SLOPING, DIFFERENTIAL TRAPPED
CONDENSE DRAINS, TO OPEN TUNDISH.
MISWIRING MOTORS COMPETENT
ELECTRICIAN.
________________________________________
TIME SCALE FOR ACTION
JOB POSN/CUST POSN/ECE POSN
PRELIM. DSGN?/FINAL DSGN?/BUDGET?
QUOTE REQUIRED BY
IF ECE SPECIFIED. WHEN?
OUT TO TENDER BY.
RETURN DATE
ORDER TO ECE CUSTOMER BY
IF ECE SELECTED. WHEN?
ORDERS TO ECE BY
DELIVERY DATE(S) REQUIRED
GUARANTEE PERIOD REQUIRED FROM.
FOB/CIF/PACKED FOR SHIPPING
CONDITIONS OF TRADING
CREDIT RATING IF APPLICABLE.