Ecom Instruments X.COM 21x -Ex Istruzioni per l'installazione

Safety instructions
x.com 21x -Ex

12
Contents
1. Application 13
2. Safety precautions 13
3. Faults and damage 13
4. Safety regulations 14
5. Ex-Data 15
6. Technical specifications 15
7. Button functions 16
8. Rechargeable battery and commissioning 17
8.1. Changing the battery 17
8.2 Commissioning/changing the SIM 17
8.3 Safety precautions for the battery 18
9. Repair 19
10. Cleaning, maintenance and storage 20
11. Disposal 20
12. Warranty and liability 21
13. EC Declaration of Conformity 22
14. Certificate of conformity 22
Note:
The current safety precautions, operating instructions, EC Declara-
tion of Conformity and the Certificate of Conformity can be down-
loaded from the relevant product page at www.ecom-ex.com, or
alternatively they can be requested directly from the manufacturer.

13
1. Application
The X.com 21x –Ex is an explosion-shielded, water-, dust- and
impact-resistant mobile phone for industrial application in areas
with an increased risk of explosion in zone 2 in accordance with
directive 1999/92/EC (ATEX 137) and 94/9/EC (ATEX 95).
2. Safety precautions
These operating instructions contain information and safety
regulations which are to be observed without fail for safe operation
in the described conditions. Non-observance of this information
and these instructions can have serious consequences or it may
violate regulations.
Please read these operating instructions carefully before starting
to use the unit! In the event of conflicting information the details
specified in the safety precautions shall apply.
In case of any doubt (in the form of translation or printing errors)
the German version shall apply.
3. Faults and damage
If there is any reason to suspect that the safety of the unit has
been impaired, it must be withdrawn from use and removed
immediately from the Ex-area. Measures must be taken to prevent
it from being restarted accidentally.
The safety of the unit may be compromised, if, for example:
- there is visible damage to the housing.
- the unit has been subjected to excessive loads.
- the unit has been improperly stored.
- the unit has been damaged in transit.
- unit markings or inscriptions are illegible.
- malfunctions occur.
- permitted limit values have been exceeded.

14
4. Safety regulations
Use of the X.com 21x –Ex explosion-shielded mobile phone assu-
mes that the operator observes the conventional safety regulations
and has read the certificate of conformity in order to eliminate
faulty operation of the unit.
The following points are to be observed:
- The unit is to be protected from increased impact.
- The unit should not be used in close proximity to processes
generating high charges.
- Friction of the housing should be avoided as far as possible for
electrostatic reasons.
- The unit should not be opened inside the Ex-area.
- The charging socket cover must be firmly engaged in the unit.
- Only the original battery module BPX 21x should be used.
- The battery module may not be changed inside the Ex-area.
- When changing the battery outside the Ex-area the unit and the
battery terminals are to be checked for cleanliness and cleaned
if necessary.
- The screws of the battery compartment cover should always be
tightened firmly by hand in order to ensure the tightness of the
unit.
- The battery module may only be charged outside the Ex-area
and only then using the following appropriate chargers:
Battery charger TCX 21x, ALX 20
Charging and data synchronisation via a USB data cable that has
been connected to a device tested according to EN 60950.
The USB signals are specified at Um = 6 V.
- The battery module may only be charged in a temperature range
of 0 °C - 45 °C.
- Only accessories approved by ecom instruments GmbH may be
used.
- The stereo headset (optional accessory) that is required for using
the radio function should only be connected outside the Ex-area.

15
- It must be ensured that the unit is not taken into zones 0, 1, 20,
21 or 22 .
- Observe the corresponding laws that are in force in the respe
tive country regarding the use of mobile phones while operating
a vehicle.
- Use of the mobile phone in an aeroplane is not permitted.
- Switch off the mobile phone when in close proximity to medical
instruments and if you are requested to do so by corresponding
regulations.
- Manufacturers of cardiac pacemakers recommend a minimum
distance of 15.3 cm (6“) is maintained between a mobile phone
and a pacemaker.
- Do not switch on the mobile phone when the use of such devices
is prohibited, as it may cause interference or result in danger.
5. Ex-Data
Certificate of conformity: ecom-10-501 X
Ex-Designation: II 3G Ex nA nL IIC T4 Gc
Ambient temperature range: -20 °C ... +55 °C
Approved for zone 2, device group II, explosion group IIC (explosi-
ve gases, vapours or mist), temperature class T4.
6. Technical specifications
Networks: EDGE Tri-Band 900, 1800 and 1900 MHz
Bluetooth: 2.0 (DUN, OPP, SPP, HSP, HFP)
Display: 176 x 220 pixels, 65536 colours
Power supply: ecom BPX 21x, Li-Ion 3,7 V, 1750 mAh
Dimensions: 119 x 56 x 26 mm
Weight: approx. 170 g incl. battery
CE-designation: 0
Protection class: IP 67
SAR:
The highest SAR value for the X.com 21x -Ex
which has been tested for use without a
headset is 0.582 W/kg (10 g).

16
7. Button functions
Volume control
Phonebook
Left
selection button
Accept/Make
call button
Press and
hold to
access the
mailbox
Press and hold to
lock/unlock
the keypad
For entering a ‚+‘ for
international numbers
Charging socket cover
Press and hold to
activate/deactivate
the silent mode.
Press and hold to
switch the flashlight
on/off.
On/Off/Call
end button
Right selection button
Camera (optional)
Menu button
Navigation buttons
(up/down/left/right)

17
8. Rechargeable battery and commissioning
8.1. Changing the battery
The BPX 21x battery module used in the X.com 21x –Ex unit
should only be changed outside the Ex-area. Only those battery
modules which are approved by the manufacturer for your unit
type (see safety regulations, point 4) may be used. Other battery
modules should not be taken into the Ex-area.
8.2 Commissioning/changing the SIM
1. Unscrew the cover:
Switch off the phone. To open the battery compartment turn the
screws in the cover anti-clockwise.
2. Lift the cover:
Remove the battery compartment cover.
3. Insert the SIM:
Remove the battery from the unit by lifting it up. Insert the SIM card
underneath the metal holder on the right-hand side.
4. Insert the Micro SD card (optional):
Slide the left-hand metal tab to the top and fold it upwards. Then
insert the Micro SD card into the slot, fold down the metal tab and
slide it downwards until it engages in place.
5. Insert the battery:
Insert the battery. Close the cover for the battery compartment.
Tighten the screws of the battery compartment clockwise.
6. Charge the mobile phone:
The battery supplied with the phone is not fully charged. It is
recommended to charge the phone for eight hours before using
it for the first time. The full capacity of the battery is reached after
4-6 complete charge/discharge cycles.
On/Off/Call
end button

18
Note:
- There is a risk of explosion if the battery is not exchanged
properly or if it is exposed to a flame.
- Do not short-circuit the battery.
- The battery does not contain any parts that can be exchanged.
- The casing of the battery should not be opened under any
circumstances.
- Only use ecom charging accessories (see point 4).
- The use of other chargers or batteries is not permitted.
Ex-protection cannot be guaranteed in this case.
- Used batteries are to be disposed of properly.
- If the phone is not going to be used for a prolonged period, the
battery should be removed.
- The battery module should only be stored within a range of -20 °C
to +35°C (for up to 6 months) or within a range of -20 °C to +45 °C
(for up to 1 month).
- The charge level of the battery module should be checked after
6 months at the latest in order to prevent deep discharge.
- The phone should not be connected to the charger if the battery
is not inserted.
- If the battery is completely discharged, the phone will not switch
on and the display will not show a charging process. Connect
the phone to the charger. After charging for a few minutes the
display will appear again and you can then switch on the phone.
8.3 Safety precautions for the battery
Damaged batteries and chargers should be removed from use and
sent to ecom instruments GmbH for inspection.
Note:
- Extreme temperatures can have an adverse effect on charging
the battery module.
- Do not dispose of the battery module in a fire.
- Do not short-circuit the battery module.

19
- Dispose of the battery module in accordance with local regulations.
- Do not dispose of the battery module with normal household
waste.
High quality lithium-ion batteries are used in your X.com 21x
–Ex. These batteries have numerous advantages in everyday
use, such as a low weight and high capacity in a nevertheless
compact construction. In addition these batteries also exhibit
practically no memory effect.
However, these batteries are susceptible to a natural ageing
process which impairs their functionality. Modern batteries
today have a lifespan of around 500 charge cycles, which,
when used daily, corresponds to a service life of approximately
2 years. The ageing process increases rapidly after this period,
which means that the batteries are deemed technically defecti-
ve after 500 charge cycles. Moreover, the batteries could blow
up and cause irreparable damage to your device in a worst
case scenario.
For this reason rechargeable batteries with lithium cells should
be replaced after 2 years at the latest or after reaching a batte-
ry capacity that is 50% of its initial value.
Note:
The battery used in this unit poses a fire hazard and can cause
chemical injuries if it is used improperly. Neither the battery nor
the battery cells should be opened or disassembled and they
should not be burned or exposed to temperatures exceeding
100 °C.
9. Repair
Repairs are to be conducted by ecom instruments GmbH or by
personnel or service centres authorised by ecom instruments
GmbH, because the safety of the unit needs to be tested after
repairs are implemented.

20
10. Cleaning, maintenance and storage
- Only use a suitable cloth or sponge to clean the phone.
Do not use any solvents or abrasive cleaning agents when
cleaning.
- It is recommended that you have the functionality and accu-
racy of the phone inspected by the manufacturer every two
years.
- If the unit is going to be stored for a prolonged period, remove
the battery module from the unit and check its charge condi-
tion at regular intervals.
- Do not exceed the permissible storage temperature range of
-20 °C ... +55 °C!
- The battery module should only be stored within a range of -20 °C
to +35 °C (for up to 6 months) or within a range of -20 °C to +45 °C
(for up to 1 month).
11. Disposal
Old electrical devices as well as „historical“ old electrical de-
vices from ecom instruments GmbH are supplied for disposal at
our expense and disposed of free of charge in accordance with
European Directive 2002/96/EC and the German electrical law
of 16/03/2005. The costs associated with returning devices to
ecom instruments GmbH are to be borne by the sender.
In accordance with Article 1, Section 18 and Article 2 of the
Act revising the law of Waste-Related Product Responsibility
for Batteries and Accumulators (Gesetz zur Neuregelung der
abfallrechtlichen Produktverantwortung für Batterien und Akku-
mulatoren) dated 25 June 2009, we are obligated to provide the
following information.
Your device contains a rechargeable lithium battery.
Depleted batteries or rechargeable batteries that can no longer
be recharged should never be disposed of along with normal or
household waste. Old batteries can contain harmful substances
that are hazardous to health and damaging to the environment.
Please return the batteries/rechargeable batteries. Return is
free of charge and required by law. Please only dispose of
discharged batteries in the designated containers and tape the
terminals of lithium batteries.
Indice
Altri manuali Ecom Instruments Telefono cellulare

Ecom Instruments
Ecom Instruments XP3410 IS Istruzioni per l'installazione

Ecom Instruments
Ecom Instruments Ex-Handy 05 Manuale utente

Ecom Instruments
Ecom Instruments Ex-Handy 05 Istruzioni per l'installazione

Ecom Instruments
Ecom Instruments Ex-GSM 01 Istruzioni per l'installazione

Ecom Instruments
Ecom Instruments Ex-Handy 06 Istruzioni per l'installazione

Ecom Instruments
Ecom Instruments x.com 500-Ex Istruzioni per l'installazione

Ecom Instruments
Ecom Instruments Ex-Handy 05 Manuale utente

Ecom Instruments
Ecom Instruments x.com 400/401 Manuale utente

Ecom Instruments
Ecom Instruments Ex-GSM 01 EU Manuale utente

Ecom Instruments
Ecom Instruments Ex-CDMA 02 Istruzioni per l'installazione