UNPACKING
Open top flaps of carton. Gently place carton on its side.
Lift unit up slightly and then pull out by rolling on its wheels.
Place handle on top panel and fasten 3 hex screws on each side.
Handle
Front
Grill Panel

3
1. General Information
Ecozone’s ActivO is a mobile and easy-to-use deodorizing system for indoor use.
This robust, computer controlled and automatic system is characterized by high safety
standards. The system incorporates ECOZONE's unique ADA system, a double-stage
operating cycle that creates ozone and subsequently removes it, allowing the
immediate reoccupation of treated spaces.
In the first stage the room is enriched with ozone (generated from the air using
Ecozone’s multi-patented technology) at a particularly high rate in order to reach
homogeneous conditions and a high concentration level within the shortest possible
time. In the second stage, any after-treatment residual ozone is decomposed into
oxygen, so as to leave the treated room well within the regulated levels.
2. Declaration of Conformity
Model No. POCS-500 (POCS= Portable Odour Control System)
This unit fully complies with CE & FCC rules of EMC regulations.
EN 61000-61, EN 61000-62, EN 61010-1, EN 5501 EMC, FCC Part 15
Safety of Low Voltage Directive 73/23/EEC as Amended: EN 61010-1.

4
1
11
1
2
22
2
3
33
3
Safety Precautions & Warnings
Read this manual carefully before operating the unit.
Do not expose this equipment to rain or moisture. Should any liquid
come into contact with the system, unplug it and have it serviced by
qualified personnel before operating it further.
Unplug the system power plug when it is not in use.
When unplugging, never pull the plug by the cord itself.
DO NOT enter the treated room during the operation of the system,
or before hearing the completion-of-cycle audio alert-signal.
This system is equipped with a ventilation inlet and a ventilation outlet.
DO NOT BLOCK inlet/outlet or place foreign objects in their vicinity which
may block air flow. Place unit in the CENTER of the room.
DO NOT disconnect cable cord from mains socket
before the operation of the system is completed.
This unit is supplied with a earthed cable.
Attempting to bypass the earth or to connect
the unit to an un earthed socket is strictly prohibited.
Under no circumstances should the unit be operated
with the front panel grill loose or missing.
Prior to removing the grill for maintenance, always
disconnect the unit from power.
AVOID ELECTRICAL SHOCK
There are no user
serviceable parts inside the ActivO; removal of back panel by
unauthorized personnel will result in voiding the WARRANTY!

5

6
3. Technical Specifications
5.1 Description
The ActivO system is a portable high-duty and rugged system.
It features the most advanced technology in the field of odour-
control and air-treatment. The ActivO employs Ecozone’s
state-of-the-art and patented Singlet Unit which is characterized
by relatively high activation rate and enhanced reliability.
5.2 Technical Specifications:
Input Voltage: 230V; 60Hz
Air Flow-Rate: 450 m³/h.
Ozone output: 12g/h (12,000 mg/h)
Operation: Fully Automatic Activation & Deactivation Cycles.
Cycle time: Minimum 15 minutes, Maximum 48 hours.
With special input code: 72 hours, ozone generation only
Control: Digital keyboard
Display: LCD, 16 Digits.
Safety: Circuit breaker (overload switch): 4A
Amber Flashing Light Indicator (ActivO in operation)
Red Fault Indicator
Buzzer Alarm (operation has begun; operation has ended)
Differential Pressure Regulator (air flow obstructed)
Door Interlock (front panel not closed)
Dimensions: 50 x 40 x 100 cm, with handle attached
53 x 65 x 94 cm, packed for shipping, handle detached
Ozone outlet duct: 4″diameter
Weight: 37 kg; packed for shipment 40 kg
Enclosure: Metal and ABS
Wheels: leave no tracks
Low EM Noise.
Certification: CE & FCC

7
5.3 Normal Environmental Conditions:
Indoor use only
Temperature: 0 ºC to 35 ºC
Humidity: maximum relative humidity: 95%;
ECOZONE Technologies has a policy of continuous product improvement and
reserves the right to modify or change this specification at any time without notice.

8
4. Operation
Preparation and Connections
Connect power cord to socket on ActivO’s rear panel (bottom) and only
then connect it to the power source socket.
6.1 Controller settings
OZONE IS A POWERFUL OXIDIZER. USE THIS EQUIPMENT WITH CARE
AND IN UNINHABITED AREAS ONLY. READ ALL OPERATING
INSTRUCTIONS BEFORE USING THIS MACHINE.
RE-
OCCUPY TREATED ROOM ONLY AFTER PRESET OPERATING TIME HAS
ELAPSED AND THE AMBER FLASHING LIGHT HAS STOPPED FLASHING
INDICATING THAT THE MACHINE IS NO LONGER IN OPERATION.
DO NOT ATTEMPT TO ENTER THE ROOM WHILE MACHINE
IS IN OPERATION; VENTILATE ROOM AFTER USE
CAUTION

9
Press the ‘STOP’ (Red) button to Reset.
STOP / RESET
The display will present a code followed by the alternating
prompt: Ready and Set Room Size.
Select ‘Room Size’ by pressing the respective keypad button.
Note: You may choose between the following 4 room sizes:
Small; for room volumes below 30m3.
Medium; for room volumes between 30m3and 60m3.
Large; for room volumes between 60m3and 120m3.
X-Large; for room volumes from 120m3to 500m3
The display will now prompt: Set Time
Select the Short/Intermediate/Long time cycle by pressing
the respective button on keypad.
O
Note: Select length of cycle to correspond
with the odour level in the room.

10
Short Cycle-Time (Light odor)
Intermediate Cycle-Time (Average odor)
Long Cycle-Time (Strong odour)
Refine Time setting (optional) by pressing the Up or Down blue-arrow
buttons to extend or to shorten the operation cycle time, respectively.
Please refer to reference chart on page-13.
Up - to extend cycle-time
Down - to shorten cycle-time
Note: Time is indicated on LCD in hours and minutes.
h=hours and m=minutes.
For example 3 hours and 20 minutes would be indicated so: