ECUE Butler PRO Guida utente

Butler PRO
Setup Manual

Butler PRO Setup Manual
Edition/Ausgabe: 2013-07-26
Published by/Herausgegeben von:
Traxon Technologies Europe GmbH
Karl Schurz-Strasse 38
Paderborn, Germany
©2013, Traxon Technologies Europe GmbH
All rights reserved/Alle Rechte vorbehalten
Comments to/Bemerkungen an:

Table of Contents
English......................................................................5
Safety instructions.................................................................................... 6
System description................................................................................... 7
System diagram ....................................................................................... 7
Connections ............................................................................................. 8
Frontplane ........................................................................................... 8
Backplane ........................................................................................... 8
Terminal pinning....................................................................................... 8
Mounting and installation ......................................................................... 9
Unit distribution.................................................................................... 9
User interface ........................................................................................... 9
Operational messages............................................................................ 10
Display and keypad use..................................................................... 11
Parameter setup..................................................................................... 11
Device Info mode............................................................................... 12
Setup mode....................................................................................... 12
Advanced Settings mode................................................................... 14
Test mode.......................................................................................... 14
Network parameters .......................................................................... 18
Connecting more than one Butler PRO.............................................. 20
Firmware update .................................................................................... 21
Troubleshooting ..................................................................................... 22
Technical specifications......................................................................... 24
Deutsch ..................................................................26
Sicherheitshinweise................................................................................ 27

Gerätebeschreibung............................................................................... 28
Systemdiagram ...................................................................................... 28
Anschlüsse ............................................................................................. 29
Frontplatte ......................................................................................... 29
Rückseite........................................................................................... 29
Pin-Belegung.......................................................................................... 29
Montage ................................................................................................. 30
Platzierung im Rack ........................................................................... 30
Benutzeroberfläche ................................................................................ 30
Betriebsanzeigen.................................................................................... 31
Nutzen der Anzeige und des Tastenkranzes....................................... 32
Parameter-Einstellungen........................................................................ 32
Grundeinstellungen............................................................................ 33
Erweiterte Einstellungen (Advanced Settings)..................................... 35
Test-Modus (Test mode) .................................................................... 36
Netzwerk-Parameter.......................................................................... 39
Anschluss mehrerer Butler PRO......................................................... 41
Firmware-Update ................................................................................... 42
Fehlerbehebung ..................................................................................... 43
Technische Daten................................................................................... 44
Appendix ................................................................46
Dimensions/Abmessungen..................................................................... 47
Notes/Notizen......................................................................................... 48

5
Setup Manual - Butler PRO
English

6
Setup Manual - Butler PRO
Safety instructions
!
The product must only be installed and put into operation by a qualified
electrician. The applicable safety regulations and accident prevention
regulations must be observed. Otherwise the unit may be damaged.
Only work on the product when it is de-energized to prevent electrical
shocks. Incorrect handling may damage the unit.
!
Do not route network, DMX/e:pix or any other communication line
together with power lines. Data traffic or functions can be disturbed.
!
The product may only be operated in the operating modes described
in the manual. All other applications are considered to be inappropriate
use. If the product is not used as intended, there is no guarantee that it
will operate safely.
!
To prevent the device from overheating, only operate it in well-ventilated
environment. The ventilation slots may not be obstructed. Otherwise the
unit may overheat and fail.
Device components can reach high temperatures! Let unit cool down
after operation before mounting or removing unit to avoid burnings.
!
Repairs may only be carried out by authorized, specially trained person-
nel to ensure reliability. When in doubt, contact e:cue service. Incorrect
handling may damage the unit
!
It is imperative that main power is supplied via an isolating device and
a circuit-breaking device (power contactor) in any case, which can be
controlled at all times.

7
Setup Manual - Butler PRO
System description
The e:cue Butler PRO is a 16 channel DMX/RDM or e:pix interface that acts as an
interface between a server running the e:cue Lighting Application Suite and devices
with DMX512 or e:pix connections. The Butler PRO usually gets mounted in a
universal 19-inch rack system or on walls or ceilings.
The server connection is a standard CAT5 RJ45 based Ethernet interconnect. The
device connection is also RJ45 based. All usual CAT5 RJ45 cables can be used.
Please note that e:net requires an isolated network segment and cannot
operate properly when using e. g. Internet traffic or video/audio stream-
ing in the same network simultaneously.
System diagram
e:cue LAS
Butler PRO Butler PRO Butler PRO
16 x output channels
DMX512/RDM or e:pix
Ethernet switch
16 x output channels
DMX512/RDM or e:pix
16 x output channels
DMX512/RDM or e:pix
Use standard CAT5 RJ45 Ethernet cabling between server, switch and Butler
PRO. Connection without Ethernet switch and with an Ethernet cross cable is not
recommened. To connect DMX using a XLR5 type plugs, please use a adaptor
cable, item number 40005, available as accessory or contact your nearest e:cue
distributor for a suitable adaptor cable.

8
Setup Manual - Butler PRO
Connections
Frontplane
System display
Cursor keys
OK key (center)
OK
Status >
online DMX 35Fps
Backplane
1 3 5 7
2 4 5 6
9 11 13 15
10 12 14 16
Ethernet
Output ports 1 ... 16
Ethernet/e:net Power
Terminal pinning
pin no. signal
1 DMX-/e:pix-
2 DMX+/e:pix+
3 GND
4 n/c
5 n/c
6 n/c
7 n/c
8 n/c

9
Setup Manual - Butler PRO
Mounting and installation
Mount the Butler PRO in a standard 19-inch rack system. Use appropriate rack
screws, cage nuts and spring clips for mounting.
Unit distribution
As the Butler PRO has no active cooling, place a
maximum of two units together, leave one unit free
or place a passive device, followed by the next two
units. Additionally care for:
yclosing of unused units with rack plates
ymounting in a fan-ventilated closed rack
yplacement of the rack in an air conditioned room
Connect the Butler PRO with the outputs of the Ethernet switch and with power.
When installing and mounting more than one Butler PRO in factory state,
make sure that only one Butler PRO gets connected and configured at
one time. If connecting more than one device with the factory IP address
(192.168.123.1) the Ethernet connection will not work
User interface
The Butler Pro comes with a circular keypad and an LC display for operation
and setup. During regular operation the Butler PRO displays status and opera-
tional messages on the display. When in setup mode, parameters and values are
displayed, the keypad is used for selecting parameters and changing values. Only
keypads, that are allowed at a certain state, are lit up, either in operational or in
setup mode. This picture is the Butler PRO DMX.
System display
Cursor keys
OK key (center)
OK
Status >
online DMX 35Fps

10
Setup Manual - Butler PRO
After powering up the Butler PRO, the loader shows the loading progress and
revision levels of the loader and the firmware. After loading is completed, the Butler
PRO enters operational mode. The setup mode must be selected separately.
During online operation, usually the IP address and other network parameters are
shown, also the host address of the server running the Programmer of the Lighting
Application Suite. All used values for parameters are just examples, they depend on
the configuration of your Butler PRO.
Operational messages
After powering-up and loading the Butler PRO cycles through this set of status
messages (DEVICENAME is the name given via manual or online setup):
Butler PRO <DMX>
©2013 traxon/ecue
Start screen of the Butler PRO DMX.
Butler PRO <EPIX>
©2013 traxon/ecue
Start screen of the Butler PRO e:pix.
*** ERROR ***
no snapshot found
After booting the Butler PRO is offline (no LAS
server present) and no snapshot was stored
for offline state. Press the OK-key to clear the
message and save a snapshot for offline state as
shown later.
DEVICENAME
<offline>
The Butler PRO is in offline mode and not con-
nected to the Programmer of the LAS.
DEVICENAME
no output
The Butler PRO does not output any data (no
snapshots defined).
DEVICENAME
IP: 192.168.123.123
The IP address of this Butler PRO.
DEVICENAME
MASK: 255.255.255.0
The netmask that is used for the IP connection,
default is 255.255.255.0
DEVICENAME
<online>
The Butler PRO is in online mode, connected to
the Programmer of the LAS.
DEVICENAME
Mode: DMX 35 Fps
The Butler PRO DMX name and speed, the maxi-
mum possible framerate is 35 fps
Indice
Lingue:
Manuali Apparecchiature di registrazione popolari di altre marche

Strymon
Strymon NIGHTSKY Manuale utente

Mitsubishi Electric
Mitsubishi Electric 16CH DIGITAL RECORDER DX-TL5000U Manuale utente

Tews Technologies
Tews Technologies TPMC465 Manuale utente

Honeywell
Honeywell Excel 50 Manuale utente

SeaLevel
SeaLevel COMM+8.LPCI Manuale utente

Arturia
Arturia AUDIOFUSE STUDIO Manuale utente