5.1 - Utilities: *1electrical power –110/240 VAC, 50/60 HZ.
*2Compressed air supply –60 PSI & 3 CFM minimum.
5.2 - Reference material: units of measure –English/Metric
upper and lower part limits
setting master *3calibrated sizes
5.3 - Measuring tooling: LVDT probes –open setup
electronic bore plug –I.D. measurement
electronic ring gage –O.D. measurement
air plug –I.D. measurement
air ring –O.D. measurement
special gage
5.4 –Setting masters: max & min or *4zero size masters -
gageblocks or other types of masters –for
electronic “open”setup gaging
ring type –for electronic or air gaging of I.D.’s
cylindrical OD type –for electronic or air gaging
of O.D.’s
Footnotes:
1.) electrical power should be “clean”and stable without large fluctuations otherwise internal
damage of electrical components can occur voiding warranty. In such cases a isolation
transformer is recommended.
2.) Clean & dry compressed air is required. Normal compressed air (shop air) can contaminate the
docking units effecting stability of the readings and voiding warranty. In such cases a coalescing
air filter is recommended to be installed on the inlet to the docking unit. The elements in this
filter require periodic checking and replacement.
3.) Certifications by a traceable calibration lab are recommended to ensure the setup and results of
calibration are as accurate as possible.
4.) A zero or nominal master can be used but not recommended by Edmunds Gages for electronic
gaging only. Two masters are required for air gaging.