Page 10
Select de function of the instrument.
“cn.1” - Counter - Input impulses on channel A. Channel
B disabled.
“cnq.2” - Counter for quadrature signals - Input impulses
in quadrature (bidirectional encoder) on channels A and B.
“cnI.3” - Counter + inhibit control - Input impulses on chan-
nel A. Inhibition control inhibit on channel B.
“cnc.4” - Counter + control add / substract- Input im-
pulses on channel A. Control for function add or substract,
on channel B.
“cnd.5” - Counter differential - Input impulses with add
function on channel A. Input impulses with substract function
on channel B.
“rt.6” - Ratemeter - Input impulses on channel A. Channel
B disabled.
“rtq.7” - Ratemeter for quadrature signals - Input impulses
in quadrature (bidirectional encoder) on channels A and B.
“Prd.8” - Periodmeter - Input impulses on channel A. Chan-
nel B disabled.
The selected function (“Func”) modies the conguration
menu (“cnF.x”) presented by the instrument.
1.
12
.1 Function mode
Select the position for the decimal point. Modify with the LE
button and validate with the SQ button.
1.12.2 Decimal point
1.12 Conguration menu descriptions
The “cnF.1” menu is visible only when function mode “cn.1”
‘counter’ is selected. Impulses received are internally count-
ed, multiplied by the “MuLt” parameter, divided by the “dIV”
parameter, and the result is updated on display.
Multiplier (“MuLt”) - Value from 1 to 999999. Multiplier factor
to be applied to the total number of impulses counted.
Divider (“dIV”) - Value from 1 to 999999. Divider factor to be
applied to the total number of impulses counted.
Preset (“PrSt”) - Value from 999999 to -199999. Reset
activation loads on display the preset value.
Mode (“ModE”) - Value “uP” / “doWn”. Select “uP” for up
counter (received impulses add). Select “doWn” for down
counter (impulses received substract).
‘FAST’ mode (“FASt”) - Value “on” / “oFF”. See section 1.14
1.12.3 “cnF.1” - Counter
The “cnF.2” menu is visible only when function mode “cnq.2”
‘counter quadrature’ is selected. Impulses received are in-
ternally counted, multiplied by the “MuLt” parameter, divided
by the “dIV” parameter, and the result is updated on display.
Multiplier (“MuLt”) - Value from 1 to 999999. Multiplier factor
to be applied to the total number of impulses counted.
Divider (“dIV”) - Value from 1 to 999999. Divider factor to be
applied to the total number of impulses counted.
Preset (“PrSt”) - Value from 999999 to -199999. Reset
activation loads on display the preset value.
Edges (“q.124”) - Value “1--1”, “1--2” or “1--4”. Select “1--
1” to count 1 impulse per quadrature cycle. Select “1--2” to
count 2 impulses per quadrature cycle. Select “1--4” to count
4 impulses per quadrature cycle.
1.12.4 “cnF.2” - Counter quadrature
The “cnF.3” menu is visible only when function mode “cnI.3”
‘counter + inhibit’ is selected. Impulses received are internally
counted, multiplied by the “MuLt” parameter, divided by the
“dIV” parameter, and the result is updated on display.
Multiplier (“MuLt”) - Value from 1 to 999999. Multiplier factor
to be applied to the total number of impulses counted.
Divider (“dIV”) - Value from 1 to 999999. Divider factor to be
applied to the total number of impulses counted.
Preset (“PrSt”) - Value from 999999 to -199999. Reset
activation loads on display the preset value.
Mode (“ModE”) - Value “uP” / “doWn”. Select “uP” for up
counter (received impulses add). Select “doWn” for down
counter (impulses received substract).
Inhibit (“Inh”) - Value “on_h” / “on_0”. Select “on_h” to inhibit
counting when channel B is at logic state ‘1’. Select “on_0” to
inhibit counting when channel B is at logic state ‘0’.
1.12.5 “cnF.3” - Counter + Inhibit
The “cnF.4” menu is visible only when function mode “cnc.4”
‘counter + control add / substract’ is selected. Impulses
received are internally counted, multiplied by the “MuLt”
parameter, divided by the “dIV” parameter, and the result is
updated on display.
Multiplier (“MuLt”) - Value from 1 to 999999. Multiplier factor
to be applied to the total number of impulses counted.
Divider (“dIV”) - Value from 1 to 999999. Divider factor to be
applied to the total number of impulses counted.
Preset (“PrSt”) - Value from 999999 to -199999. Reset
activation loads on display the preset value.
1.
12
.6 “cnF.4” - Counter + Control A/S