6
3. Press to add selected song/songs to the Clipboard. If storage capacity in
Clipboard has exceeded the limit, a warning indication will be shown (FIGURE 11);
likewise, you can refer to the capacity indicator for the percentage of being
occupied storage.
4. Once you’ve completed song selections, press to download selected songs
to the Bell. A saving prompt box will appear while data is saving (FIGURE 12).
FIGURE11 FIGURE12
Advanced Operation (Programming)
To following information is for someone that has some experience setting up a Z-Wave
system or someone that has computer software running a Z-Wave Controller.
Through Controller, you can enquire the current status of Door Bell or set the Door Bell
to return reports according to the settings as below.
1. Supported Z-Wave Commands
Door Bell will respond to BASIC and BINARY commands that are part of the
Z-Wave system.
1-1 BASIC_GET / SWTICH _ BINARY _GET / SENSOR_BINARY_GET
Upon receipt of the following commands from a Z-Wave Controller, the Door
Bell will report its current status (playing/ NOT playing) to the Controller.
BASIC_GET Command
[Command Class Basic, Basic Get]: enquire the current status of the Door
Bell, i.e. Door Bell is playing or not playing a song currently.
BASIC_REPORT Command
[Command Class Basic, Basic Report, Value = 0(0x00)]:report Door Bell
is not playing.
[Command Class Basic, Basic Report, Value = 255(0xFF)]: report Door
Bell is playing a song currently.
SWITCH BINARY GET Command
[Command Class Switch Binary, Switch Binary Get]: enquire the current
status of the Door Bell, i.e. Door Bell is playing or not playing a song
currently.
SWITCH BINARY REPORT Command
[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]:
report Door Bell is not playing
[Command Class Switch Binary, Switch Binary Report, Value =
255(0xFF)]: report Door Bell is playing a song currently.
SENSOR_BINARY_GET is equivalent to SWITCH_BINARY_GET;
SENSOR_BINARY_REPORT is equivalent to SWITCH_BINARY_REPORT.
SENSOR BINARY GET Command
[Command Class Sensor Binary, Sensor Binary Get]: enquire the current
status of the Door Bell, i.e. Door Bell is playing or not playing a song
currently.
SENSOR BINARY REPORT Command
[Command Class Sensor Binary, Sensor Binary Report, Value =0(0x00)]:
report Door Bell is not playing
[Command Class Sensor Binary, Sensor Binary Report, Value =
255(0xFF)]: report Door Bell is playing a song currently.
1-2 BASIC_SET / SWTICH _ BINARY _SET
Upon receipt of the following commands from a Z-Wave Controller, the Door
Bell can be set to playing / NOT playing.
[Command Class Basic, Basic Set, Value = 0(0x00)]: Set the Door Bell to
stop playing.
[Command Class Basic, Basic Set, Value = 255(0xFF)]: Set the Door Bell
to play.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]:
Set the Door Bell to stop playing.
[Command Class Switch Binary, Switch Binary Set, Value = 255(0xFF)]:
Set the Door Bell to play.
1-3 BATTERY_GET / BATTERY REPORT
You can also enquire the battery status of the Bell by sending BATTERY_GET
command via controller. Once Bell receives the command, it will return
BATTERY_REPORT command.
BATTERY_REPORT Command
[Command Class Battery, Battery Report, Battery Level =20%-100%]