7
4
6
Connect the mains cold water to the unit’s inlet (7), and preheated water outlet (8) from
the unit to the cold side of the shower mixer tap and/or domestic water heater (depending
on installation configuration). Use both of the provided Male 1/2’’ fittings and proceed to
their sealing in accordance with good plumbing practice.
Connect the ZYPHO drain water outlet (9) to the drain pipe sewer/floor drain.
Put the shower tray and components (1), (2), (3) and (4).
We recommend to perform a leak test on the mains water circuit and on the drain water
circuit to ensure the integrity of the inlet and outlet connections.
5