EIPL K100E Manuale utente

Page 1 of 16
Drawing : - TPC452
Issue : - 2
Date : - 23/05/16
K100E
DEHUMIDIFIER
OWNER’S MANUAL
www.eipl.co.uk

Page 2 of 16
Drawing : - TPC452
Issue : - 2
Date : - 23/05/16
K100E
PACKAGE CONTENTS
Item Description Quantity
10185GE-US Dehumidifier 1 off
3086144 Quick release hose coupling 1 off
3944110 PVC Tube – 3/8” I/D 7.8M
TPC452 Manual 1 off

Page 3 of 16
Drawing : - TPC452
Issue : - 2
Date : - 23/05/16
INTRODUCTION
Dehumidifiers remove moisture from the air that is circulating through the unit.
The resulting reduction of relative humidity helps prevent rust, rot, mold,
mildew and condensation within the room, or other enclosed spaces where
the dehumidifier is used.
The K100E has a number of special features:
•
Ebac’s “Reverse Cycle” defrost system
•
Integral pump out system
•
Provision for permanent drainage
•
Exterior epoxy powder-coated finish
•
Extra long power cord
•
Free Standing or Wall Mountable
•
Status Indicator
•
Electronic Humidity Control
The fan draws air through the refrigerated surface and cools it below its dew
point, removing moisture which is collected and led away. The cool air then
passes the hot condenser, where it is reheated. With the addition of other
radiated heat the air is discharged into the room at a higher temperature but
lower relative humidity than when the air entered the unit. Continuous
circulation of the room air through the dehumidifier unit gradually reduces the
relative humidity in the room.
The K100E controls consist of an electronic humidity controller, incorporating
Bluetooth connectivity and Real Time Clock, allowing the unit to interface with
Android and IOS smart phones and provide additional control and data
logging features. The respective apps are available for free download through
the normal channels
Smartphone App
The Smartphone interface allows the following additional functions
a) Real time monitoring of the relay status and room conditions
b) Adjustment of Control set point (To allow this functionality, the link fitted to
J3 on the main controller board, will need removing)
c) Data logging of, Time, Temperature, Humidity, Relay Status, Control and
Alarm Set points
d) Adjusting the data Logging Interval
e) Resetting the data log
f) Downloading logged data
g) Emailing logged data in RAW or CSV formats (Allowing importing into
Excel)

Page 4 of 16
Drawing : - TPC452
Issue : - 2
Date : - 23/05/16
The K100E dehumidifier is a rugged reliable drying unit designed to operate
effectively over a broad range of temperature and humidity conditions. A
powerful and reliable reverse cycle defrost system, controlled by an electronic
timer, guarantees positive de-icing and thereby optimizing operation at low
temperatures.
The unit incorporates a welded steel chassis and is finished in epoxy coated
steel covers for resilience to damage caused by rough handling.

Page 5 of 16
Drawing : - TPC452
Issue : - 2
Date : - 23/05/16
SPECIFICATIONS
"This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The
refrigeration system is hermetically sealed.
The Global Warming Potential (GWP) of refrigerants used in products manufactured by Ebac
Industrial Products Ltd is as follows
R134a – 1300
R407c – 1610
For type and weight of refrigerant contained in this unit, please refer to the product data label"
M
ODEL
:
10185GE-US
H
EIGHT
:
27.2” (692mm)
W
IDTH
:
22.8” (580mm)
D
EPTH
:
18.3” (464mm)
W
EIGHT
:
117 Lbs (53Kg)
A
IRFLOW
:
300 CFM (510 M3/Hr)
P
OWER
S
UPPLY
:
110V 1Ph 60Hz
P
OWER
1500 W (max)
F
INISH
:
Epoxy coated steel
R
EFRIGERANT
T
YPE
/Q
TY
:
R407C (540g)

Page 6 of 16
Drawing : - TPC452
Issue : - 2
Date : - 23/05/16
INSTALLATION
POSITIONING:
Position the dehumidifier unit in the center of the room to be conditioned if at
all possible. However if a damp patch is particularly apparent the outlet grille
should be pointed towards it.
NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have
clear space around them and not be obstructed in anyway.
WIRING:
Connect the power mains cable to a designated 30 Amp breaker. As follows:-
For Models without plugs:-
Brown Live
Blue Neutral
Green/Yellow Earth (ground)
DRAINAGE:
The K100E has a water pump fitted as standard which is capable of
discharging the condensate water 20ft vertical lift away from the unit & 100ft
horizontal. The water can, therefore, be discharged into a drain some distance
away.

Page 7 of 16
Drawing : - TPC452
Issue : - 2
Date : - 23/05/16
OPERATION
The following procedures should be followed to test the K100E for correct
operation:
1. After unpacking, examine all external features to confirm damage-
free shipment. Report all defects and damage at once. Connect the
power cable to a grounded electrical outlet.
2. Setting the Digital Humidistat
•Turn fully clockwise
3. Check dehumidification process as follows:
A. Place unit on a level surface.
B. Start up unit by turning the ON/OFF switch to ON
C. Check that the compressor is running.
D. Leave the machine running for 15 minutes.
E. Observe the evaporator coils through the rear upper grill, to
confirm frost operation.
i. If the air temperature is below 80°F, an even coating of
frost should cover the entire evaporator coil
ii. If the air temperature is above 80°F, frost and/or droplets
of condensed water should cover the entire
evaporator coil.
F. After continuous running time of approximately 55 minutes, the
unit will enter “Hot Gas” defrost mode for 5 minutes and then
automatically return to normal operation.
TO ENSURE CONTINUED FULL EFFICIENCY OF THE
DEHUMIDIFEIR, MAINTENANCE PROCEDURES SHOULD BE
PERFORMED AS FOLLOWS:

Page 8 of 16
Drawing : - TPC452
Issue : - 2
Date : - 23/05/16
If, after carrying out the above procedures, the unit does not appear to
function properly, refer to the Trouble Shooting section, which follows,
or contact the Factory Service Center.
Discharge Pump
The pump works automatically and periodically pumps away collected
moisture to a drain or container. The pump is capable of discharging water to
a vertical height of 20ft.
Warnings.
•Due to the high pressures within the refrigeration circuit, under no
circumstances must direct heat be applied to the evaporator coil in an
attempt to remove the build up of ice.
•No attempt should be made to cut open any part of the refrigeration circuit
due to high pressures and gas involved.
•If the unit is switched off at the mains power supply for any reason, the unit
must be allowed to stand at rest for at least three minutes before
restarting.
CAUTION:
ONCE THE UNIT HAS BEEN SWITCHED OFF, WAIT AT LEAST FIVE
MINUTES BEFORE RESTARTING.

Page 9 of 16
Drawing : - TPC452
Issue : - 2
Date : - 23/05/16
ROUTINE MAINTENANCE
To ensure continued full efficiency of the dehumidifier, maintenance
procedures should be performed as follows:
1. Clean the surface of the evaporator and condenser coils by blowing the
dirt out from behind the fins with compressed air. Hold the nozzle of the air
hose away from the coil (approx 6”) to avoid damaging the fins.
Alternatively, vacuum clean the coils.
2. Check that the fan is firmly secured to the motor shaft and that the
fan rotates freely.
THE FAN IS SEALED FOR LIFE AND DOES NOT NEED LUBRICATING.
3. To check the refrigerant charge, run the unit for 20 minutes (with
humidistat set to maximum) and briefly remove the cover. The
evaporator coil should be evenly frost coated across its surface. At
temperatures above 77°f, the coil may be covered with droplets of
water rather than frost. Partial frosting accompanied by frosting of
the thin capillary tubes, indicates loss of refrigerant gas or low
charge.
4. Check all wiring connections.
I
F ANY OF THE PRECEDING PROBLEMS OCCUR
,
CONTACT THE
E
BAC
S
ERVICE
C
ENTER PRIOR TO CONTINUED OPERATION OF THE UNIT TO
PREVENT PERMANENT DAMAGE
.
WARNING:
ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN
DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTENACE ON
ITEMS 1, 2, 3, AND 4.
WARNING:
DO NOT STEAM CLEAN REFRIGERATION COILS

Page 10 of 16
Drawing : - TPC452
Issue : - 2
Date : - 23/05/16
REPAIRS
1. Should an electrical component fail, consult the Factory Service
Center to obtain the correct replacement part.
2. If refrigerant gas is lost from the machine, it will be necessary to use
a refrigeration technician to correct the fault. Contact the Factory
Service Center prior to initiating this action.
Any licensed refrigeration technician will be able to service the
equipment. The following procedure must be used:
a. The source of the leak must be determined and corrected.
b. The machine should be thoroughly evacuated before
recharging.
c. The unit must be recharged with refrigerant measured
accurately by weight.
d. For evacuation and recharging of the machine, use the crimped
and brazed charging stub attached to the side of the refrigerant
compressor.
The charging stub should be crimped and rebrazed after
servicing. N
EVER
allow permanent service valves to be fitted to
any part of the circuit. Service valves may leak causing further
loss of refrigerant gas.
3. The refrigerant compressor fitted to the dehumidifier is a durable
unit that should give many years of service. Compressor failure can
result from the machine losing its refrigerant gas. The compressor
can be replaced by a licensed refrigeration technician.
Failure of the compressor can be confirmed by the following
procedure:
a. Establish that power is present at the compressor terminals
using a voltmeter.
b. With the power disconnected, check the continuity of the internal
winding by using meter across the compressor terminals. An
open circuit indicates that the compressor should be replaced.
c. Check that the compressor is not grounded by establishing that
a circuit does not exist between the compressor terminals and
the shell of the compressor.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali EIPL Deumidificatore

EIPL
EIPL BD75P Manuale utente

EIPL
EIPL EBAC PD120 Manuale utente

EIPL
EIPL EBAC PD200 Manuale utente

EIPL
EIPL CD85 Manuale utente

EIPL
EIPL CS60 Manuale utente

EIPL
EIPL RM40P Manuale utente

EIPL
EIPL CD425 Manuale utente

EIPL
EIPL RM40 Manuale utente

EIPL
EIPL ECO150 Manuale utente

EIPL
EIPL HM150-H Manuale utente