USE, CARE, AND
INSTALLATION MANUAL
Read all lnstructions before installing and operating the appliance
XP02293(1)
EVL36SW
ESL36SW.BW
EFL30GW
EFL36GW
ESQ30SW
ESQ36SW


1
SAFETY NOTICE .......................................... 2
INSTALLATION
Mounting Height & Clearance ........................ 3
Ducting Options ............................................. 4
Hood Specifications ...................................... 5-7
Mounting the Range Hood ............................. 8
Ductless Recirculating................................ 9
FEATURES & CONTROLS
Touch Controls .............................................. 10
MAINTENANCE
Cleaning and Metal Mesh Filter Care ............ 11
Lights ..............................................................12
13
TROUBLESHOOTING...................................

IMPORTANT SAFETY NOTICEIMPORTANT SAFETY NOTICE
2

3
InstallationInstallation
Minimum mount height between range top to hood
bottom should be no less than 28”
Maximum mount height should be no higher than
36”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
result in heat damage and fi re hazard; while hoods
mounted too high will be hard to reach and will
lose its performance and effi ciency.
If available, also refer range manufacturer’s height
clearance requirements and recommended hood
mounting height above range. Always check your
local codes for any differences.
DUCTING
A minimum of 6” round or 3-1/4”x10” rectangular
duct must be used to maintain maximum air flow
efficiency.
Always use rigid type metal ducts only. Flexible
ducts could restrict air fl ow by up to 50%.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size from 6” to 7” or 8”.
If turns or transitions are required; install as far
away from opening and as far apart, between 2,
as possible.
- Mounting Height & Clearance
Minimum Mounting Height (Ducted)
8’. Hood mounted 28” above cooking surface;
64” from floor.
Minimum Mounting Height (Recirculating)
8’4”. Hood mounted 28” above cooking surface;
64” from floor.
Maxmimum Mounting Height
10’3”. Hood mounted 36” above cooking surface;
72” from floor.
Duct cover extension kit available for ceiling
heights up to 14 feet.

4
InstallationInstallation
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics
or garages.
All exhaust must be ducted to the outsid, unless using the recirculating option.
Use single wall rigid Metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape.
Some Ducting Options
- Ducting Options

5
InstallationInstallation -Hood Specifications
ESQ-30/36 SW
ESL-30/36-SW.BW

6
InstallationInstallation -Hood Specifications
EFL-30/36GW

7
InstallationInstallation -Hood Specifications
EVL-30.36SW

InstallationInstallation
8
- Mounting the Range Hood
CAUTION: At least two installers are
required due to the weight and size of the
hood.
1. Measure from range top to hood bottom and mark line A.
(28”minimum from range top)
2. Plum and mark center line.
3. Mark mounting height line B. (10-3/8”from line A)
4. EVL series - Mark mounting spread from C/L on line B. (4”)
ESQ/ESL series - Mark mounting height line B. (8”)
EFL series -Mark mounting height line B. ( 15-3/8”)
5. Fasten (2) M4x1-1/4” screws into studs on line B. Do not
fasten screws all the way. note: wood blocking may
need to be added behind the drywall if no studs are
present. Wall anchors may also be used, check local
codes before using wall anchors.
6. Hang hood onto screws and hand tighten. (Fig.A) Use
the last M4x1-1/4”screw to further secure the hood to
the wall from inside the hood.
7.Center and attach duct cover bracket to wall below
ceiling or soffit using (2) M4x1” screws.
8.Install electrical.
9.*Install duct work and duct tape.
10.Power up hood and check for leaks around duct tape.
11.Place telescopic duct covers onto hood and extend
inner (top) duct cover upwards and secure to duct cover
bracket using (2) M4x3/8” screws.
*if using hood in recirculating mode you must secure air
diverter plate onto wall before installing duct work and
duct covers. Turn to page 9 for more details.
!
!
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
Cable Lock
A cable locking connector (not supplied) might
be required by local codes. Check with local
requirements and codes, purchase and install
appropriate connector if necessary.