Elan PVSE Manuale utente

PVSE
INSTALLATION
MANUAL
ELECTRONIC VOLUME CONTROL
PRECISION PANEL
TRIGGERS
12 4356ALL
IR IN
IR OUT
12 4356ALL
12 4356ALL
HOME SYSTEMSTM


ELAN HOME SYSTEMS PVSE INSTALLATION MANUAL
© ELAN Home Systems 2005 • All rights reserved. Page 1
Table of Contents
Introduction ........................................................... 2-3
Features .................................................................3
PVSE Front/Rear Panels .......................................4
Installation ............................................................. 4-6
PF2 Precision Panel Frame .................................. 4
Mounting PVSE to PF2 ......................................... 5
Trim-Out .................................................................6
Connections-ELAN System ............................7-21
ELAN System Overview & Wire Runs .................. 7
Rear Panel Connections ................................... 8-18
RJ-45 Pin Out ........................................................8
Punch-Down Connectors ..................................... 8
VSE 1-6 Connections ............................................9
VSE IR OUTPUTS Connections/PS12 ..................10
VSE IR OUTPUTS Connections/S12 .................... 11
VSE IR OUTPUTS Connections/S6 ...................... 12
VSE IR OUTPUTS Connections/PZ6 ....................13
VSE IR OUTPUTS Connections/Z•630 ................ 14
OVERRIDE IN Connections/PZ600 ...................... 15
OVERRIDE OUT Connections/PZ600 ...................16
OVERRIDE IN Connections/PZ6 .......................... 17
OVERRIDE OUT Connections/PZ6 ...................... 17
IR ROUTING Dipswitch Settings .......................... 18
Front Panel Connections .................................. 19-21
TRIGGERS ............................................................. 19
IR IN ....................................................................... 20
IR OUT ................................................................... 21
Connections-Stand-Alone .............................. 22-27
Stand-Alone Overview & Wire Runs .................... 22
Rear Panel Connections ................................... 23-24
VSE 1-6 Connections ............................................23
IR ROUTING Dipswitch Settings .......................... 24
Front Panel Connections .................................. 25-28
TRIGGERS ............................................................. 25
IR IN ....................................................................... 26
IR OUT ................................................................... 27
Power Supply Connections ........................... 28
Warranty ......................................................Back Page

PVSE INSTALLATION MANUAL ELAN HOME SYSTEMS
Page 2 © ELAN Home Systems 2005 • All rights reserved.
HOME SYSTEMS
TM
2428 Palumbo Dr.
Lexington, KY USA 40509
Voice 859.269.7760
Tech Support 800-622-3526
Introduction
The PVSE Precision Panel makes it easy to connect up to six ELAN
Electronic Volume Controls (VSE, VSE100, and VEHP) to ELAN S
Series and Z•Series equipment, and is also the perfect trim-out
solution for Electronic Volume Controls in any stand-alone system.
The PVSE is one of ELAN’s 1/2 frame Precision Panels and is
designed to be mounted in a PF2 Precision Panel Frame (see
page 4). Two 1/2 frame Precision Panels can be mounted in one
standard-size Precision Panel Frame, giving the flexibility to mix and
match the Precision Panels needed to complete a neat, problem-free
trim-out.
The back of the PVSE features six clearly labeled 110 punchdown
blocks that provide independent connections for Override, IR, and
Sense; plus two additional connectors for easy routing of Electronic
Volume Control IR signals to the System12 Precision Panel (PS12).
Two RJ-45 jacks on the rear of the panel make it easy to route
Override signals from the PZ600 Communications Controller
Precision Panel and link multiple PVSE panels together. There is
also a bank of six dipswitches that allow you to turn the front panel
volume control-specific IR Out ports into ‘ALL’ ports. In stand-alone
applications, this allows all six Electronic Volume Controls to control
any or all sources.
The PVSE’s front panel was designed with stand-alone applications
in mind. Six Trigger Inputs, plus a Trigger ‘ALL’ port, allow you to
mute any or all Electronic Volume Controls whenever voltage is
not present. Six IR Inputs, plus an ‘ALL’ port, allow a VIA!®SR1 or
VIA!®2-SS1 to independently control Electronic Volume Controls
connected to the panel. Six IR Out ports, plus an ‘ALL’ IR Out port,
allow each or all VSEs to control source components in a stand-
alone system.
Electronic Volume Controls that are connected to the PVSE are
powered by the included PWR12 +12VDC/2A power supply.

ELAN HOME SYSTEMS PVSE INSTALLATION MANUAL
© ELAN Home Systems 2005 • All rights reserved. Page 3
Introduction (continued)
Features
• 1/2 Frame Precision Panel for Six ELAN Electronic
Volume Controls (VSE, VSE100, and VEHP)
• 110 Punchdown Connectors w/ Clearly Labeled
Silkscreen for Error-Free Terminations
• Easy to Interface with PS12 and PZ600 Precision Panels
• Multiple PVSEs Can Be Linked Together
• Front Panel Trigger and IR In/Out Jacks
for Stand-Alone Applications
• 12VDC, 2A Power Supply Included
• Fits in PF2 Precision Panel Frame (required for installation)
• Punchdown Tool & Caps Included
PVSE Front/Rear Panels
• TRIGGERS (Inputs)
Connects to Triggering Device
• IR IN
Connects to IR Source
• 12VDC/2A
Connects to PWR12 Power Supply
• IR OUT
Connects to Source to be Controlled
• VSE 1-6
Connects to ELAN Electronic Volume
Controls (VSE, VSE100, VEHP)
• IR ROUTING Dipswitches
Controls IR OUT IR Routing
• VSE IR OUTPUTS
Connects to ELAN Multi-Zone
Controllers
• OVERRIDE OUT
Connects to additional PVSE
• OVERRIDE IN
Connects from a PZ600, Z•600,
or additional PVSE
TRIGGERS
12 4356ALL
IR IN
IR OUT
12 4356ALL
12 4356ALL
SENSEGV+NC NCIROVCO IRI
SENSENC V+ GIROVCO IRI NC
VSE 2 VSE
3
VSE 5 VSE 4
VSE 6
SENSEGV+NCNC
IRI
IROVCOSENSEIROVCO NC
IRI NC V+ VCO NC
IRI
IRO V+NC SENSE
GG IR G
IR
G
IR GGGG
VSE IR
OUTPUTS
OVERRIDE
OUT
OVERRIDE
IN
123
45
GG
IR
6
IR
ALL
123456
IR ROUTING
IR
SENSENC V+ GIROVCO IRI NC
VSE 1
GG
Front
Rear

PVSE INSTALLATION MANUAL ELAN HOME SYSTEMS
Page 4 © ELAN Home Systems 2005 • All rights reserved.
Installation
PF2 Precision Panel Frame
The PF2 accommodates any two 1/2 frame Precision Panels.
The kit includes a full-size Precision Panel frame, an insert with pre-
drilled holes for the mounting of two 1/2 frame Precision Panels,
mounting screws, and a blank 1/2 frame plate to cover an unused
half of the frame. PBKT6P new-construction brackets are available,
or the PF2 can easily be retro-fitted using the four clamping legs
attached to the frame, which clamp the panel securely to drywall.
Note: The PF2 is required for the installation of all 1/2 frame
Precision Panels.

ELAN HOME SYSTEMS PVSE INSTALLATION MANUAL
© ELAN Home Systems 2005 • All rights reserved. Page 5
Installation (continued)
Mounting the PVSE to the PF2
Each 1/2 frame Precision Panel mounts from the back of the PF2.
Use four included screws inserted from the front of the PF2 as
shown below.
Screw
Screw
Screw
Screw
PF2 Front
Front
TRIGGERS
12 4356ALL
IR IN
IR OUT
12 4356ALL
12 4356ALL

PVSE INSTALLATION MANUAL ELAN HOME SYSTEMS
Page 6 © ELAN Home Systems 2005 • All rights reserved.
Installation (continued)
Trim-Out
All system wire runs are pulled through the PF2 frame. Lay the PVSE
front panel (attached to the PF2) on the floor in front of the frame
and make all connections. Dress the wires in neat bundles, being
careful not to pull off any punchdown connections, and then carefully
place the PVSE/PF2 back into the frame and secure using the four
screws.
Wire Runs

ELAN HOME SYSTEMS PVSE INSTALLATION MANUAL
© ELAN Home Systems 2005 • All rights reserved. Page 7
Connections-ELAN System
PVSE ELAN System Overview and Wire Runs
XM FM
123456
+
--
1
ZONE
1
LOCAL
22
ZONE LOCAL
33
ZONE LOCAL
4
ZONE
4
LOCAL
55
ZONE LOCAL
6
ZONE
6
LOCAL
8
LOCAL
8
ZONE
7
LOCAL
7
ZONE VIA!POWER
16VDC / 10A
16VDC / 4A
VIA!NET
TO SENSE INPUTS
USE STEREO 3.5mm PLUGS ONLY
EXTIR ANTENNA
+12VDC
Power
Supply
PS12
PZ600
V
SE/VEHP
PWR12
(included)
TRIGGERS
12 4356ALL
IR IN
IR OUT
12 4356ALL
12 4356ALL
VSE/VEHP VSE/VEHP VSE/VEHP VSE/VEHP VSE/VEHP
To Z•600
To S12
1
1
1
2
1Cat-5
2ELAN C4545 RJ-45 Interconnect Cable

PVSE INSTALLATION MANUAL ELAN HOME SYSTEMS
Page 8 © ELAN Home Systems 2005 • All rights reserved.
ELAN System Connections (continued)
Rear Panel Connections
RJ-45 Pin Out
ELAN recommends using ELAN C4545 and/or C45P RJ-45 intercon-
nect cables for all Cat-5 connections to the PVSE. Should you prefer
to terminate your own RJ45 cables, refer to the diagram below for
the correct pin-out.
PVSE Punch-Down Connectors
The back of the PVSE uses standard 110 punchdown connectors for
all wire runs. Wires do not need to be stripped prior to punchdown
as the insulation will automatically be displaced. Each punchdown
row will accept two 24 or 22 AWG solid conductor wires. Use the
included 110 punchdown tool to properly make connections and
avoid damaging the PVSE.
110 Punch-Down Connecto
r
NOTE:
The PVSE comes with punch-
down caps to ensure that
connections won’t come loose.
Indice
Altri manuali Elan Pannello di controllo