PRODUCT DATA SHEET
Revision Y05-01Service Manual - COMPACT
Model Indoor Unit IOD-12
Model Outdoor Unit CON-12
Installation Method of Pipe Flared
Characteristics Units Cooling Only Cooling Heating
Capacity (1) Btu/hr 12620 12450 12620
kW 3.7 3.65 3.7
Power input (1) kW 1.29 1.26 1.25
EER (Cooling) or COP(Heating) (1) W/W 2.87 2.90 2.96
Energy efficiency class CCD
Power supply V/Ph/Hz 230V/Single/50Hz
Rated current A 5.7 5.7 6.0
Starting current A 30
Circuit breaker rating A 15
INDOOR
Fan type & quantity Cross flow x 1
Fan speeds H/M/L RPM 1250/1000
Air flow (2) H/M/L m3/hr 600/450
External static pressure Min-Max Pa 0
Sound power level (3) H/M/L dB(A) 54/47
Sound pressure level(4) H/M/L dB(A) 42/36
Moisture removal l/hr 1.7
Condensate drain tube I.D mm 16
Dimensions WxHxD mm 840*250*180
Weight kg 8
Package dimensions WxHxD mm 930*265*325
Packaged weight kg 11
Units per pallet units 36
Stacking height units 9 levels
OUTDOOR
Refrigerant control Capillary tube
Compressor type, model Rotary, TOSHIBA PG215X2C-4FS
Fan type & quantity Propeller(direct) x 1
Fan speeds H/L RPM 735
Air flow H/L m3/hr 1550
Sound power level H/L dB(A) 66 67
Sound pressure level(4) H/L dB(A) 56 57
Dimensions WxHxD mm 760*545*245
Weight kg 37 38
Package dimensions WxHxD mm 880*610*310
Packaged weight kg 40.5 40.5
Units per pallet Units 12
Stacking height units 4 levels
Refrigerant type R407C
Refrigerant chargless distance kg/m 1.015kg/m
Additional charge per 1 meter g/m 4m<Lin<7.5m:+10g/m 7.5M>Lin>15m:+15g/m
Connections between
units
Liquid line In.(mm) Ф 1/4”(6.35)
Suction line In.(mm) Ф 1/2”(12.7)
Max.tubing length m. Max.15
Max.height
difference m. Max.7
Operation control type Remote control
Heating elements kW
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.