SCR
immer
STIKSTIK
STIKSTIK
STIK
3
Operation
19
3
4
4
5
7
68 3
Diagram of Stik with PBG connectors
1. DMX Input: A 5 pin Opto-Isolated XLR connector on
the end of the Stik. The input connector
is mounted adjacent to the power cord.
2. Power Cord: With strain relief cable clamp.
3. Load
Connectors: Varies with the type of connectors
ordered.
4. Fuse Holders: Each dimmer in the Stik has a fuse to
provide supplemental protection. These
fuses will protect the dimmer in the event
of a short circuit or overload condition.
Replace with6.25A 250VACceramic slow
blow fuses.
5. Last Stik Switch: When on, this terminates the DMX-512
data line. If the Stik is at the end of a
cable, this switch should be on. Only the
last Stik in the DMX-512 data link should
have this switch set to the “On” position.
A yellow LED indicates when the
termination is active.
6. Start Address: Threerotary switchesto selectthe dimmer
starting address. Set the switch from 001
to 509 to select the desired starting
address for the first dimmer in the Stik.
(Address for dimmer number 1) The
remaining three dimmers will follow in
sequence, one after another. Setting the
starting address to 000 will disable the
DMX-512 input.
7. LED Indicators: Power, DMX, and Overtemp LED
indicators.
8. Test/Focus: These buttons operate in two modes. If
the Stik is connected to a valid DMX-512
transmission, the button cause the
corresponding dimmer to fade to 100%,
the LED above the button will flash to
indicate that the dimmer is in test mode.
Pressing the button again will cause the
dimmer to return to the current DMX-512
level. If the dimmer is left in test mode, it
will time-out after about 2½ minutes, and
the dimmer will revert back to the current
DMX-512 level. When no valid DMX-512
transmission is being received, the Test
button may be used to manually adjust
the output level of the dimmer. Pressing
the button will raise or lower the dimmer
output. Multiple presses may be used to
set the dimmer to the desired level. The
LED above the button will show the ap-
proximate dimmer output. As long as no
DMX-512 signal is being received, the
dimmer will stay at the desired level.
9. DMX Output: The output connector may be used to
string additional Stiks together. All 5 pins
are connected between the input and out-
put connectors. The pin-out is as follows:
1 - Signal Ground
2 - Data-
3 - Data+
4 - Not used
5 - Not used
Note: DMX output should not be used
when the Last Stik switch (#5) is in the
“On” position.
2
Left End Right End
FrontView
SideView