Elenos ELT50 Manuale utente

Via G. Amendola 9 - 44028 Poggio Renatico (FE) - Italy
Ph. +39 0532 829 965 - Fax +39 0532 829 177
E-Mail: [email protected]
Web Site: www.elenos.com
USER AND TECHNICAL MANUAL
Edizione 1
Rev. 0 - 02/07/2009
Cod. MAN0168
ELT50
ELR50

Page 2 Engineering Department PHONE: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: [email protected]
AVVISO IMPORTANTE
Il presente apparato è utilizzabile solo da
titolari di Concessioni Governative
e/o Autorizzazioni Ministeriali
Elenos Srl
WARNING
The use of this device
is subject
to National Regulations.
Elenos Srl
Back to index
Use and maintenance manual

Page 3
Engineering Department PHONE: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: [email protected]
Back to index
Use and maintenance manual
REVIEWS

Page 4 Engineering Department PHONE: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: [email protected]
Back to index
Use and maintenance manual
First of all thank you for choosing an product.
products are solid state or thermionic tube transmitters that develop power
from a minimum of 20W to a maximum of 30KW.
Great care has been taken during the design of the protection circuitry to ensure compa-
tibility with products from other manufacturers. However the best performance is achieved
when the equipment is used with other products manufactured by .
The unit has been designed to guarantee stable performances over time, without the need
of special maintenance, minimised to a functional fans-check.
Operation of the unit is very easy and intuitive. Even so it is recommended that this manual
and other relevant documentation is read carefully before any operation.
Dear User,
Customer Care

Page 5
Engineering Department PHONE: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: [email protected]
Back to index
Use and maintenance manual
INDEX
TECHNICAL CHARACTERISTICS 6
USAGE INSTRUCTION 9
Display Password 11
Display Change of Frequency 13
TECHNICAL SCHEMATICS ELR50 15
TECHNICAL SCHEMATICS ELT50 60

Page 6 Engineering Department PHONE: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: [email protected]
Back to index
Use and maintenance manual
1. TECHNICAL CHARACTERISTICS
TECHNICAL CHARACTERISTICS

Page 7
Engineering Department PHONE: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: [email protected]
Back to index
Use and maintenance manual
1. TECHNICAL CHARACTERISTICS
Frequency Ranges
200~240 MHz - 300~330 MHz
400~470 MHz - 940 - 960 MHz
(other on request)
Type of Modulation FM Class F3
VCO Tuning 25 MHx
Frequency Stability ± 2.5 ppm (Better on request)
Synthesizer Step 25KHz
Image Rejection 60dB Typ.
RN Noise Figure 6dB or lower
Stereo Separation > 45 dB @ 1 KHx
Distorsion < 0.5% (TYP 0.2 % @ 1KHz)
Base Band 30 Hz - 60 KHz within 0.15 dB
Unweighted S/N Ratio > 72 dB with 0.2 mV input (Typ 78 dB)
Deenphasis 50 or 75 µS
RF Connectors N-F 50 ohm
Base Band-If Connectors BNC-F
Base-Band Impedence 30 ohm
Cooling Forced air
P. Temperature Range 0 ÷ +45°C
Maximum Umidity 90%
AC Supply 100 ÷ 240 Volt; 47 ÷ 63 Hz
DC External Supply (option) 15 Volt Negative Ground
Dimension 3 Units Rack 19" 44 cm Depth
Weight 6.5 Kg

Page 8 Engineering Department PHONE: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: [email protected]
Back to index
Use and maintenance manual
1. TECHNICAL CHARACTERISTICS
Frequency Ranges
200~240 MHz - 300~330 MHz
400~470 MHz - 940 - 960 MHz
(other on request)
Type of Modulation FM Class F3
VCO Tuning 25 MHz
Frequency Stability ± 2,5ppm (Bettr 0n request)
Synthesizer Step 25KHz
Power Output 10 Watts
Spurious Emission < -80 dB or better
Harmonic Emission < -65 dB (-80 dB on request)
Stereo Separation > 55 dB @ 1 KHz
Distorsion < 0.2% (TYP 00.8 %) @ 1KHz)
Base Band 30 Hz - 60 KHz within 0.15 dB
Unweighted S/N Ratio > 74 dB rms at 30 Hz ~ 20 KHz
Enphasis 50 or 75 μS - selectable
RF Connectors N-F 50 ohm
Input Base Band Impedence 2 Kohm
Input Mono Impedence 600 Ohm
Cooling Forced air
OP. Temperature Range 0 ÷ +45°C
Maximum Umidity 90%
AC Supply 100 ÷ 240 Volt; 47 ÷ 63 Hz
DC External Supply (option) 12~15 Volt Negative Ground
Dimension 3 Units Rack 19" 44 cm Depth
Weight 7.3 Kg

Page 9
Engineering Department PHONE: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: [email protected]
Back to index
Use and maintenance manual
2. USAGE INSTRUCTION
USAGE INSTRUCTION

Page 10 Engineering Department PHONE: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: [email protected]
Back to index
Use and maintenance manual
2. USAGE INSTRUCTION
ELENOS
Connected a 50 load or 50 antenna to the RF output, connect the
equipment into a mains supply (100÷240 VAC) with earth point. The
transmitter equipment is factory pre-set to 0.0 W.
Switch ON the power switch and the yellow V POWER led will light.
The Display will show:
After 3 seconds the green PLL LOCK led will light and the Display will
show an increasing bar, after a further 5 seconds the green ON AIR led
will light and there will be output power.
At this point the Display will show the next parameter for the transmitter:
•Level Modulation (MOD > );
•Forward Power (FRW 5.0W);
•Reflected Power (RFL 0.1W);
instead for the receiver:
•Level Modulation (MOD > );
•Level Signal(50dBuV).
WAIT
WAIT
MOD >
FRW 8.0W RFL 0.0W
Questo manuale è adatto per i seguenti modelli