Elinchrom ELC 125 Manuale utente

ELC
125/500
User manual


Table of contents
Introduction 4
ELC 125, 500 characteristics 6
Before you start 7
General user and safety information 7
Display panel - Dashboard Menu 14
Daylight modelling lamp 16
Skyport Sync Mode 19
Menu Features 17
Flash Mode Setup 20
Replace a Flashtube 22
Troubleshooting 23
Disposal and recycling 25
Technical Data 26
Legal Information 30
Declaration of conformity USA & Canada 32
ELC
125/500
User manual ELC 125/500 ELINCHROM — 3

Introduction
Dear photographer,
Thank you for buying the Elinchrom ELC 125 / 500
compact ash unit. All Elinchrom products are
manufactured using the most advanced technology.
Carefully selected components are used to ensure the
highest quality and the equipment is submitted to
many tests both during and after manufacture. We
trust that it will give you many years of reliable service.
Please read the instructions carefully before use, for
your safety and to obtain maximum benet from many
features.
Your Elinchrom-Team
4— ELINCHROM ELC 125/500 User manual

This manual may show images of products with
accessories, which are not part of sets or single units.
Elinchrom set and single unit congurations may change
without advice and may differ in other countries.
Please nd actual congurations at www.elinchrom.com
For further details, upgrades, news and the latest
information about the Elinchrom System, please regularly
visit the Elinchrom website. The latest user guides
and technical specications can be downloaded in the
“Support” area.
Technical data, features and functions of Elinchrom
ash units, accessories and the Skyport system may
change without advice. The listed values can differ due
to tolerances in components, or measuring instruments.
Technical data, subject to change. No guarantee for
misprints.
Keep this user manual for later information and
reference.
User manual ELC 125/500 ELINCHROM — 5

ELC 125, 500
characteristics
The ELC units offer Manual, Action, HSS and TTL modes.
The TTL (Through the Lens Metering) mode allows you to
access fully automatic exposure setups according to your
digital camera capabilities. If you wish to work in the
manual mode or combine both modes, the unit enables
you to save the TTL exposure parameters as a starting
point when passing to the manual mode.
The unit supports Skyport radio remote control and HSS.
It offers fast ash durations at lower power levels.
Characteristics:
• Two ELC versions are available with 125 and 500 Ws
with Manual, TTL and HSS modes.
• 7 f-stops power range for the ELC 500.
• Action mode for optimised ash duration.
• Daylight LED modelling lamp power in 40 adjustment
levels.
• HSS and TTL is supported on the Transmitter PRO,
with the latest rmware update.
• The dedicated Group colour is visible at the
illuminated Elinchrom side logos.
• USB socket for rmware updates and Sync socket
3.5 mm.
6— ELINCHROM ELC 125/500 User manual

• Elinchrom standard mount for accessories.
• 7/8 mm umbrella shaft.
• New ergonomic design with large OLED colour
display.
Elinchrom TTL mode
• 7 f-stop ash power range for the ELC 500.
• TTL +/- 3 f-stops adjustable in 1/3 steps.
• LED modelling lamp is adjustable in 40 power steps.
• Compatible with Canon, Nikon, Fujilm, Sony,
Olympus /Panasonic and Pentax.
Manual mode
• Compatible with all Skyport Transmitters.
• Flash power in 1/10 f-stop steps.
• Saves the TTL power as a starting point for the
manual mode.
Before you start
GENERAL USER SAFETY INFORMATION
• Flash units are powerful light sources. Please be
aware of the danger, or inconvenience, that they may
present to some persons and children.
• Keep ash units out of reach of unauthorised persons
whenever possible.
• Keep ash units away from children!
User manual ELC 125/500 ELINCHROM — 7

• According to safety regulations, we draw your
attention to the fact that electronic ash units are
not designed for extreme outdoor use, in damp or
dusty conditions and should not be used after being
exposed to sudden temperature changes causing
condensation. The humidity protection conforms to
the norms of IP20.
• Do not use without permission in restricted areas
(such as hospitals, laboratories, etc.).
• Do not use near ammable / explosive material. Keep
minimum 1m or more distance to any object.
• Never ash into the eyes of a subject without
warning. Close use may affect eyesight.
• The ambient temperature whilst the unit is in use:
min. -20°C (-4°F) up to max. 35°C (95°F). Storage
temperature: -10°C up to 60°C.
• There is high voltage and there can be high currents,
so please apply all the usual safety precautions when
handling the unit.
• Do not connect the ash unit to the mains without a
mounted and working ashtube due to high voltage
at the exposed terminals!
• Flash systems store electrical energy in capacitors by
applying high voltage.
• The units may retain an internal charge for a
8— ELINCHROM ELC 125/500 User manual

considerable time even though disconnected from
the battery. Internal defective charge capacitors may
explode whilst the unit is in use, so never switch on a
ash unit, once it has been found to be faulty.
• For your safety, never open or disassemble your
ashes. Only an authorised service engineer should
open or attempt to repair this unit.
• Always switch off the ash unit before changing
accessories.
• The unit, the ashtube and accessories may become
very hot during and after use! To avoid injuries,
handle with an insulating cloth or wait until parts
have cooled down. Avoid direct sunlight, which
might heat up the ash unit and affect the photocell
efciency. Protect the ash unit when used in humid
conditions, but ensure ventilation for cooling!
• On no account should any object be inserted into the
ventilation holes.
• Use only original Elinchrom Accessories. Damaged
cables, glass domes and cases must be immediately
replaced by customer service.
User manual ELC 125/500 ELINCHROM — 9

WARNING: PHOTOSENSITIVITY / EPILEPSY / SEIZURES
A very small percentage of individuals may experience
epileptic seizures or blackouts when exposed to certain
light patterns or ashing lights. These conditions may
trigger previously undetected epileptic symptoms or
seizures in persons who have no history of prior seizures
or epilepsy. If you, or anyone in your family, has an
epileptic condition or has had seizures of any kind,
consult your physician before using the EL unit.
IMMEDIATELY DISCONTINUE use and consult your
physician before resuming use of your EL unit if you
or any person experiences any of the following health
problems or symptoms:
• Dizziness
• Eye or muscle twitches
• Disorientation
• Any involuntary movement
• Altered vision
• Loss of awareness
• Seizures or convulsion
OUTDOOR USE
CAUTION! PROTECT THE ELC AGAINST HUMIDITY!
This product is designed for dry use and should not come
into contact with water or dust. In humid conditions
cover or otherwise protect the unit.
10 — ELINCHROM ELC 125/500 User manual
Altri manuali per ELC 125
1
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Elinchrom Flash della fotocamera

Elinchrom
Elinchrom Style FX 100 Manuale utente

Elinchrom
Elinchrom D-Lite 4 it Manuale utente

Elinchrom
Elinchrom ONE Manuale utente

Elinchrom
Elinchrom RX 1200 Manuale utente

Elinchrom
Elinchrom Ringflash 3000 Manuale utente

Elinchrom
Elinchrom RX 1200 Manuale utente

Elinchrom
Elinchrom Style BX 100 Manuale utente