ELPRO ECOLOG-PRO Series Manuale utente

ECOLOG-PRO
Modules
Operation Manual

Document: EP6001Eb
2 - EN
ELPRO-BUCHS AG
Warranty conditions and liability disclaimer
Liability - ELPRO-BUCHS AG does not accept any liability for direct, indirect, special, incidentally occurring, randomly occurring or subsequent damage
or losses including lost profit or data resulting from the use of their data loggers, sensors, accessories, software products or information from
the documentation.
- ELPRO-BUCHS AG does not bear any responsibility for the installation of the software products.
- ELPRO-BUCHS AG does not provide any guarantees, either explicit or implicit, regarding the usability or suitability of their products for a
specific purpose.
- In the interest of our customers we reserve the right to make changes and discontinue the product on the basis of technical advancement. For
this reason the functionality, diagrams, descriptions and scope of supply can be modified without prior notification!
- As individual countries or states do not permit the concept of an implicit warranty or a liability disclaimer for incidental or subsequent damage,
the restrictions and disclaimers may not apply to all customers. If one of the provisions of this warranty is declared by a competent court to be
invalid or not enforceable, this does not affect the validity or enforceability of the remaining provisions.
- ELPRO-BUCHS AG does not accept any liability for transport damage or any consequential damage arising therefrom.
- In general the statutory regulations of Switzerland apply. The place of jurisdiction is the district court of Werdenberg-Sarganserland.
Guarantee - The guarantee obligations of ELPRO-BUCHS AG are limited to reworking, reimbursement of the purchasing price, repair free of charge or the
replacement of a faulty product that is returned within the guarantee period to ELPRO-BUCHS AG or an approved reseller of ELPRO-BUCHS
AG.
- There is no obligation to provide on-site customer support by an employee of ELPRO-BUCHS AG.
- The guarantee is only applicable to the original purchaser or end user and customer of an approved reseller of ELPRO-BUCHS AG.
- Resellers approved by ELPRO-BUCHS AG are not authorized to enter into any extended or different guarantee obligations in the name of
ELPRO-BUCHS AG.
- ELPRO-BUCHS AG provides a guarantee of 24 months on the following new products:
- Data logger
- Brackets
- Accessories excluding sensors and third-party products
- This guarantee is valid for material faults or production faults.
- ELPRO-BUCHS AG provides a guarantee of 6 months for the following products and services:
- All servicing and repair work
- Pt100 sensors
- Humidity sensors
- ELPRO-BUCHS AG provides a 90 day guarantee that the medium on which the software product is supplied is free from material and
processing faults under normal conditions. All main items of the software product comply with the operating instructions and the information in
the help file.
- The guarantee does not apply to consumables, disposable batteries or any other product that ELPRO-BUCHS AG deems to be:
-misused
- modified
- replaced by an incorrect product
- damaged as the result of an accident or operational or handling conditions that do not comply with the specifications.
- Wear, cable breakage, and corrosion are not covered by the guarantee.
- For third-party products ELPRO-BUCHS AG provides the maximum guarantee period of the manufacturer.
- ELPRO-BUCHS AG only provides a guarantee and customer support for discontinued products for a limited period.
- Repair work covered by the guarantee is solely carried out at the works (ELPRO-BUCHS AG) or by an agent approved by the works.
- ELPRO-BUCHS AG does not offer any guarantee for the standard or SCS calibration of data loggers and sensors. The stated data correspond
to the situation during the calibration process.
Software - The software products of ELPRO-BUCHS AG are subject to internal quality requirements and are validated regularly at the works. In the event
of program errors, circumvention of the error is regarded as constituting its elimination.
- Software manuals do not contain either instructions on basic operation of a computer or the basic functions of the Windows® operating system.
For information on the operation of the computer or the operating system please refer to the applicable computer manuals.
Data loggers, sensors and
accessories
- ELPRO-BUCHS AG applies the highest quality standards during production of data loggers and their accessories, and implements a certified
quality management system in compliance with ISO 9001.
- For information on operation of data loggers and their accessories, please refer to the respective product documentation supplied by ELPRO-
BUCHS AG.
- During the installation of data loggers, sensors, and accessories, compliance with the locally valid installation regulations is mandatory.
- When used in potentially explosive atmospheres, the zone category and the application and safety instructions of ELPRO-BUCHS AG must be
complied with.
- In the event of a guarantee claim, customers receive a repair cost estimate from ELPRO-BUCHS AG to obtain the corresponding consent
before starting work.
- The customer will bear the transport costs incurred for any repairs carried out by ELPRO-BUCHS AG. The DAP (value added tax) is borne by
ELPRO-BUCHS AG.
- ELPRO-BUCHS AG reserves the right to invoice the customer for costs incurred for repair/part replacement..
- After repair work the product is returned to the purchaser, who will be charged with the return shipping costs (FOB shipping point).
Trademarks All stated company and product names and their trademarks are the protected property of the respective owner.

Document: EP6001Eb 3 - EN
Table of Contents
Table of Contents
1 System Description ................................................................................... 6
1.1 Configuration and Evaluation........................................................................... 7
1.2 Notes................................................................................................................ 7
2 ECOLOG-PRO LBR Communication Module........................ 8
2.1 Power Supply Unit Circuit Diagram.................................................................. 9
3 ECOLOG-PRO 4PT Pt100 Measurement Module ............... 10
3.1 Sensor Connection Cable for M12 Plug......................................................... 11
3.2 Circuit Diagram .............................................................................................. 11
3.3 Sensor Status ................................................................................................ 11
4 ECOLOG-PRO 4MA 4-20 mA Measurement Module........ 12
4.1 Circuit Diagram .............................................................................................. 13
4.2 Sensor Status ................................................................................................ 13
5 Module with Contact Inputs ECOLOG-PRO 4DI ................. 14
5.1 Contact Statuses............................................................................................ 15
5.2 Circuit Diagram .............................................................................................. 15
6 Module with Contact Outputs ECOLOG-PRO 4DO........... 16
6.1 Contact Statuses............................................................................................ 17
6.2 Alarm Indicator Power Supply and Ground.................................................... 18
6.3 Local Alarm .................................................................................................... 18
6.4 Alarm Forwarding........................................................................................... 18
7 1250 mA Power Supply Unit.............................................................. 19
7.1 Configuration Matrix....................................................................................... 19
8 ECOLOG-PRO Module Configurator........................................... 20
Accessories
Revision History

Document: EP6001Eb
4 - EN
Symbols and Description Codes Used
Information
IMPORTANT INFORMATION AND WARNINGS
DELETE Windows functions, for example Delete.
<xxxxxxxxx> Syntax for placeholders.
Placeholders are written in < > brackets.
Reference to related chapter or document.
Presentation only refers to part of the
user interface.
elproMONITOR Configures and monitors data loggers.
SM3031Db
elproUSER elproMONITOR user management.
SU6031D
elproEVENT Audit trail which complies to the cGxP Environment
requirements of elproMONITOR.
SV6031D
In the interests of our customers, we reserve the right to make any changes result-
ing from technical advances. For this reason, diagrams, descriptions, and the
scope of delivery are subject to change without notice. This manual is valid as
from Version 2017.
CHANGES OR MODIFICATIONS MADE TO THIS EQUIPMENT MAY RENDER NULL
AND VOID THE ETSI / FCC AUTHORIZATION TO OPERATE THIS EQUIPMENT.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES AND WITH RSS-210 OF
INDUSTRY CANADA. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDI-
TIONS:
(1) THE PRODUCT MAY NOT CAUSE HARMFUL INTERFERENCE.
(2) THE PRODUCT MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING
INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

Document: EP6001Eb 5 - EN
- This product is subject to CE marking.
- The manufacturer guarantees that this product complies with the relevant guidelines:
EN 61000-6-2 : 2001 and EN 61000-6-4: 2001
- FCC ID: Z45-E11645398
- IC: 9954A-E11645398
- This product must be disposed of in accordance with WEEE (Waste Electrical and
Electronic Equipment, 2002/96/EC).

Document: EP6001Eb
SYSTEM DESCRIPTION
6 - EN
1 System Description
This is a quick-start reference manual for installing the ECOLOG-PRO system. The manual
also applies to the modules listed below.
ECOLOG-PRO LBR is the communication and power supply module. It has 1 Ethernet and
1 power supply unit connection. Its purpose is for remote modules to communicate over the
Ethernet network with elproMONITOR which is installed on a server provided by the cus-
tomer. Connected ECOLOG-PRO modules are powered over the system bus.
ECOLOG-PRO 4PT is the temperature measurement module. The module has 4 inputs for
Pt100 temperature sensors. For operation, it is connected to a LAN bridge (LBR).
ECOLOG-PRO 4MA is the measurement module for analog signals. The module has
4 inputs for standard 4-20 mA signals. The monitored transmitters can be powered by the
module or by an external power supply. For operation, it is connected to a LAN bridge
(LBR).
ECOLOG-PRO 4DI is the module with 4 contact inputs (digital inputs) for the ECOLOG-
PRO system. The monitored contacts are powered by the module. For operation, it is
connected to a LAN bridge (LBR).
ECOLOG-PRO 4DO is the module with 4 alarm outputs (digital outputs) for the ECOLOG-
PRO system. For operation, it is connected to an external power supply and to a LAN bridge
(LBR).
Installation and
Operation
The minimum configuration of an ECOLOG-PRO system consists of an ECOLOG-PRO LBR,
a power supply unit, and a measurement module, for example an ECOLOG-PRO 4PT.
Housing, Module
Ground
ABS, DIN-rail housing, 140x70x60 mm, 200 grams.

Document: EP6001Eb
SYSTEM DESCRIPTION
7 - EN
1.1 Configuration and Evaluation
Configuration, calibration, and monitoring are carried out with the elproMONITOR software.
SM3031D, elproMONITOR operating instructions
1.2 Notes
Power supply unit Follow the safety and application instructions of the power supply unit. Only operate the
device using the delivered power supply unit. Use of an incorrect power supply unit may
cause damage to the device. Always replace defective or damaged power supply units.
Cleaning To clean the modules, use a slightly moist cloth. Never use thinner, gasoline, alcohol, or
any other cleaning agents since they may damage the housing.
Environmental
Conditions
• Make sure the modules are at room temperature before initial startup.
• No guarantee can be given if functions exceed the specified threshold range. Ambient
temperature 0°C to 40°C, 10% RH to 90% RH, non-condensing
• Protection class IP20

Document: EP6001Eb
ECOLOG-PRO LBR COMMUNICATION MODULE
8 - EN
2 ECOLOG-PRO LBR Communication Module
ECOLOG-PRO LBR, Part.No. 801418
Module
The communication module performs 2 functions:
• Supplies power to the measurement modules
in use.
• Acts as a connecting link between the
measurement modules and the configuration
or evaluation software.
ID number
The ID number corresponds to the module MAC
address.
Status indicator 1; module activity
• green; system activity
• blue; Ethernet activity
Status indicator 2; Ethernet status
• green; link ok
• red; link inactive
Power supply 24 VDC, -10% to +20%
• By external power supply unit
• Maximum connection cable length 30 m
• Functional ground is optional.
Maximum number of measure-
ment modules
The maximum number of measurement modules is defined by the specifica-
tions of the power supply unit or the limits of the ECOLOG-PRO LBR.
- Maximum 2500 mA, system bus
- 32 measurement modules
Power supply unit Chapter 7 1250 mA Power Supply Unit
Network connection 1xRJ45 Ethernet 10/100 Mbps
Supported standards - IEEE 802.3i, 10BASE-T
- IEEE 802.3u, 100BASE-T
Scope of supply - Communication module
- Information leaflet
The power supply unit and the Ethernet connection cable are not included in
the scope of supply.

Document: EP6001Eb
ECOLOG-PRO 4PT PT100 MEASUREMENT MODULE
10 - EN
3 ECOLOG-PRO 4PT Pt100 Measurement Module
Module
Measurement module for up to 4 Pt100 sensors
• Circuit: 4-wire connection
• Sensor class: A, recommended
• Sensor details
FP2005E.
Status indicator 1
• green; power supply ok
• blue; system bus activity
Status indicator 2
3.3 Sensor Status
ECOLOG-PRO 4PT, 801420
Measurement range -200°C to 200°C
Measurement accuracy
of module
±0.2°C Sensor error and cable fault are not considered.
Measurement resolution ±0.1°C
Cable fault - up to 30 m 4x0.25 mm2 without
shield.
- 30 m to 50 m 4x0.25 mm2 with
shield.
- 50 m to 80 m 4x0.34 mm2 with
shield.
±0.06°C
±0.1°C
±0.2°C
Logging interval 1 minute to 60 minutes Each channel is capable of logging at a separate
interval.
Date and time Internal system clock The clock is synchronized permanently to elpro-
MONITOR system time.
Module power supply Via internal system bus
Data security - Internal non-volatile memory
- 10,000 measurements
In case the network connection fails, measure-
ments continue to be logged and stored in the
internal memory.
Altri manuali per ECOLOG-PRO Series
1
Questo manuale è adatto per i seguenti modelli
5
Indice
Altri manuali ELPRO Registratore di dati

ELPRO
ELPRO Libero Ti1 Manuale utente

ELPRO
ELPRO ECOLOG-NET LP4 Manuale utente

ELPRO
ELPRO ECOLOG TN Series Manuale utente

ELPRO
ELPRO Hamster-E ET1 Manuale utente

ELPRO
ELPRO LIBERO CE Manuale utente

ELPRO
ELPRO LIBERO CE Manuale utente

ELPRO
ELPRO ECOLOG-NET LP4 Manuale utente

ELPRO
ELPRO LIBERO G Series Manuale utente

ELPRO
ELPRO HAMSTER-E EHT1 Manuale utente

ELPRO
ELPRO Libero Cx Manuale utente