Elsat iNode:0x0809 Manuale utente

iNode Care Sensor
PHT
Instruction manual
© 2016 ELSAT ®

iNode Care Sensor PHT – instruction manual ELSAT s.c.
1. About iNode
We would like to introduce a family of iNode devices working in the Bluetooth Low Energy ®. We
will show you that it's not just tags to find lost keys, whether location tags, ut still something more.
Our devices are capa le of:
these are mainly attery device.
work without attery replacement for up to 12 months, depending on the type of application and
usage.
have memory for logging events, readings of measurements, etc.
contain precise temperature, humidity sensors, accelerometer or magnetometer which allow
home automation control, care of older persons or vehicle detection.
as a remote control device, although a small power consumption, have a large range and features
unavaila le to other competitive facilities - password protection, AES encryption, control
directly from the smartphone with BT 4.0.
a unique encryption technology ensures the safety of the JPEG images recorded y our cameras.
BT4.0 - LAN or BT4.0 - GSM gateways connect iNode sensors with the Internet.
iNode can also help to control the movement of people or goods, saving the time of appearance and
disappearance (active RFID ® long range). New features related to the development of the product
is also not a pro lem – this allows to remote firmware update with PC or smartphone with
Bluetooth 4.0 ® and Low Energy Bluetooth ena led ® (Smart Bluetooth ®).
iNode Care Sensor PHT is a wireless BT4.0 precise pressure, temperature and humidity sensor
with a uilt-in memory of events. It is intended mainly to home automation and weather
stations.
The value of measured pressure, temperature & humidity is roadcasted with a period of 1.28
seconds and may e archived in internal memory along with the date and time of the event. This
allows you to specify if and when temperature and/or humidity level was a ove or elow
threshold level. The sensor can e used with iNode Care Relay. Device configuration software
allows you to specify the conditions which are met will, send an alarm, and hence ena le/disa le
external device.
Trademarks or registered trademarks:
Bluetooth Low Energy ®, Bluetooth 4.0 ®, R ID®,CSR®,Windows®, Android, Google, Microsoft, ThingSpeak, Raspberry Pi,
Domoticz, BlueZ, Linux are used for informational purposes only.
All trademarks are property of their respective owners.
page 2

iNode Care Sensor PHT – instruction manual ELSAT s.c.
2. iNode Care Sensor PHT
Install application iNode Setup and BT4.0 drivers on PC. Next run iNode Setup application (on
Windows 7 to 10 with administrative rights), and press the red utton with magnifying glass picture.
If a BLE device you want connect to is password protected you should type the password in the text
ox with a key If you press the utton you can change the type of adapter which will e used
to communication – standard BT4.0 adapter (signed CSR …), iNode Serial Transceiver (signed
COM ...) or iNode LAN (signed the name of the device).
In case the application cannot start or system error you should try to install Microsoft Visual C++
2005 Service Pack 1 Redistributable Package M C Security Update from that page:
http://www.microsoft.com/en-us/download/confirmation.aspx?id=26347.
iNode Setup will find all near y iNode devices and sort them regarding receiving signal strength.
Each type of iNode device has a different icon. For iNode Care Sensor PHT it is the first picture in
the first row in the window elow.
To configure iNode Care Sensor PHT device you should dou le click on its icon. Application
connects with this device and reads its settings:
page 3

iNode Care Sensor PHT – instruction manual ELSAT s.c.
At the top of the window there is displayed following information:
the name of the iNode family – in this case iNode Care Sensor PHT;
the unique device identifier;
attery level: 100% means 3V or greater, while 0% it is 1,8V;
humidity;
pressure;
signal strength received y this device from the BT4.0 adapter or iNode LAN;
temperature;
At the Bluetooth ta there are following items:
Name: you can change default device name typing a new one in this text ox. Its length is 16
characters maximum.
Tx power: determine the power the device roadcasts and simultaneously the range the device
can e scanned. If iNode Care Relay has set the scan range ~200m, and iNode Care Sensor
PHT has set the roadcast power -2dBm range 33% then effective distance from which the
device can e scanned is equal 200m*0,33=66m.
Eco advert mode: the attery saving mode. The device sends a roadcast frame in a 5-minute
interval. To use this mode, you must properly configure the iNode Care Relay (switch-on time
may not e less than 10 minutes). Besides, if you want the iNodeSetup.exe application can
connect with your device you must first move it, and then turn on the scan.
Send alerts: allows you to enter to which logical groups will e sent alerts.
Advertising: you can chose the channels the iNode Care Sensor PHT roadcasts advertising
frames. This way the attery life can e extended ut device can e more difficult to scan.
Additionally the advertisement interval can e chosen. This time determine how fast you can
connect with the device.
You can save modified settings y pressing the Write utton.
page 4

iNode Care Sensor PHT – instruction manual ELSAT s.c.
The picture elow shows the Security ta :
The following items can e set:
Connection is possible from this computer only: this option ena le you to protect the iNode
Care Sensor PHT access from others PCs or phones. You can reset this protection y attery
removing for at least one minute. This type of protection cannot e set in case of iNode Care
Relay.
Connection is password protected: access to the iNode Care Sensor PHT is password
protected. Password length is 16 characters maximum.
Battery removing will clear the password: if you unchecked this option than please remem er
that if you forget the password it can e cleared y manufacturer only.
You can save modified settings y pressing the Write utton.
page 5

iNode Care Sensor PHT – instruction manual ELSAT s.c.
The picture elow shows the Thermometer ta :
The following items can e set:
Alert if temperature is:
no alarm: the device does not respond to temperature changes.
greater than: device sends an alert in case a set threshold temperature value is exceeded.
less than: device sends an alert in case a set threshold temperature value is exceeded.
out of range: sends an alert in case a crossing one of the set temperature threshold.
in range: device sends an alert, in case that the temperature is etween set temperature
values.
You can change the temperature threshold value or values in the range from-30 ° C to + 70 ° C.
Archive alerts: the device saves the time of the eginning and end of any of the events selected
a ove.
Archive temperature: the device keeps the record measured temperature every 1 minute.
Temperature correction: the user can adjust the measured temperature in the range from -2 °C
to 2 °C with a resolution of 0.01 ° C.
You can save modified settings y pressing the Write utton.
page 6

iNode Care Sensor PHT – instruction manual ELSAT s.c.
The picture elow shows the Hygrometer ta :
The following items can e set:
Alert if humidity is:
no alarm: the device does not respond to humidity changes.
greater than: device sends an alert in case a set threshold humidity value is exceeded.
less than: device sends an alert in case a set threshold humidity value is exceeded.
out of range: sends an alert in case a crossing one of the set humidity threshold.
in range: device sends an alert, in case that the humidity is etween set humidity values.
You can change the humidity threshold value or values in the range from 1 % to 99 %.
Archive alerts: the device saves the time of the eginning and end of any of the events selected
a ove.
Archive humidity: the device keeps the record measured humidity every 1 minute.
Humidity correction: the user can adjust the measured humidity in the range from-20 % to 20
% with a resolution of 0.5 %.
You can save modified settings y pressing the Write utton.
page 7

iNode Care Sensor PHT – instruction manual ELSAT s.c.
The picture elow shows the Barometer ta :
The following items can e set:
Alert if pressure is:
no alarm: the device does not respond to pressure changes.
greater than: device sends an alert in case a set threshold pressure value is exceeded.
less than: device sends an alert in case a set threshold pressure value is exceeded.
out of range: sends an alert in case a crossing one of the set pressure threshold.
in range: device sends an alert, in case that the pressure is etween set pressure values.
You can change the pressure threshold value or values in the range from 261 hPa to 1269 hPa.
Archive alerts: the device saves the time of the eginning and end of any of the events selected
a ove.
Archive pressure: the device keeps the record measured pressure every 1 minute.
Pressure correction: the user can adjust the measured pressure in the range from -100 hPa to
+100 hPa with a resolution of 0,1 hPa.
You can save modified settings y pressing the Write utton.
page 8

iNode Care Sensor PHT – instruction manual ELSAT s.c.
The picture elow shows the Data ta :
Clear data utton erases the archived data memory and at the same time ena ling archiving data.
Data in memory are saved in a cyclical uffer, e.g. after it is full, the oldest data will e erased.
Memory has a capacity of 8192 records. One is the record time stamp and each entry three
temperature measurement. So there are up to 24576 results of pressure and/or temperature and/or
humidity measurement can e stored in memory.
page 9

iNode Care Sensor PHT – instruction manual ELSAT s.c.
The picture elow shows the irmware ta :
Current firmware version field shows the version and creation date of the firmware in the device.
To change the firmware in the device first select New firmware file.
Firmware is uploaded to the device after clicking Send firmware utton. Application checks if this
firmware is correct for this type of device to avoid situation that we want to upload the firmware
which needs the utton to e pressed for roadcasting in the device ut this device doesn't have it.
The fep files with the firmware, manuals or other information you can find at our technical support:
http://support.inode.pl/. User: inode no password.
page 10
Indice