Brief Instruction
Mounting of WS1000 Style
Item numbers 60201-60204, 60206-60209 (WS1000 Style),
60214 (WS1000 Style-10 PF)
Warning, mains voltage! National legal regulations are to be
observed. Installation, inspection, commissioning and
troubleshooting of the device must only be carried out by a
competent electrician.
Notes on wireless equipment
When planning facilities with devices that communicate via radio, adequate radio
reception must be guaranteed. The range will be limited by legal regulation and
structural circumstances. Avoid sources of interference and obstacles between re-
ceiver and transmitter, that could disturb the wireless communication. Those
would be for example:
• Walls and ceilings (especially concrete and solar protection glazing).
• Metal surfaces next to the wireless participants (e. g. aluminium
construction of a conservatory).
• Other wireless devices and powerful local transmitters (e.g. wireless
headphones), which transmit on the same frequency. Please maintain a
minimum distance of 30 cm between wireless transmitters for that reason.
Preparing the installation location
The device must only be installed and used in dry, interior
spaces. Avoid condensation.
Cut-out dimensions for concealed box:
W = 248 mm +1 -0 | H = 165 mm +1 -0 | D = 84 mm
An external antenna can be connected in order to improve wireless communicati-
ons. During installation, a conduit 50 cm in length should be placed beneath the
recessed housing, in which the external antenna can be mounted (antenna dimen-
sions approx. 565 x 8 x 5, L × W × H in mm):
Preparing for installation
Wall-fitting
Cavity wall fitting
Assembling the control unit with concealed box
During electrical installation, please introduce all connection cables into the con-
cealed box through the lower or upper side wall. In the process, keep the individual
connection wires short to prevent long reserve loops.
After connecting the cables screw the security covering onto the concealed box.
The security covering must be fixed before the control is put
into operation! It prevents contact with current-carrying parts
in the concealed box.
By adjusting the mounting screws, the display unit will rest flat on the wall later
and be held by the magnets safely.
Connect the flat ribbon cable to the display and place the display unit on the con-
cealed box. The magnets must be attracted by the mounting screws considerably
and the display unit must rest tightly on the concealed box.
Structure of the connector board WS1000 Style
Structure of the connector board WS1000 Style-PF
The manual with additional information about commissioning,
functions and use of the controls WS1000 Style can be down-
loaded from www.elsner-elektronik.de in the menu area "Ser-
vice/Downloads".
Conduit angled diagonally dow-
nwards (for cable access from
above or below)
Conduit angled vertically downwards (only
for cable access from above!)
concealed concealed
45°
cable
cable
box box
M16 conduit, 50 cm in length M16 conduit,
50 cm in length
The display unit is held by magnets. Re-
move the front part from the concealed
box.
Caution: The display is connected
with a flat-ribbon cable to the circuit
board in the concealed box.
Loosen the plug so that the display unit
can be removed.
Remove all parts of the transportation
lock/packing.
The security covering in the concealed
box is attached with four screws: Loosen
the screws and take off the security cover-
ing.
Remove the circuit board from the con-
cealed box to be installed a keep it in a
place where it is protected from dirt. It
may never be exposed to dust or mo-
isture!
Place the concealed box in the wall so that
the arrows point upwards.
For fitting, screw the cover (board) on to
the concealed box with the enclosed
screws.
Clamp the concealed box to the wall with
the four enclosed screws.
Upon delivery, the pouch containing the
assembly screws can be found in the con-
trol unit’s concealed box.
oder
Adjust the screws of the magnetic moun-
ting with the enclosed template. Each of
the four screws must be adjusted individi-
ally in height.
When the edge of the template rests on
the wall surface (1), the template must
rest on the mounting screws as well (2).
1
1
2
1 Multifunctional output 1
(potential-free)
2 Multifunctional output 2 (pot.-free)
3 Multifunctional output 3 (pot.-free)
4 Multifunctional output 4 (pot.-free)
5 Outer conductor L1
6 Outer conductor L1
7-11Drive group 1-5
12-16Drive group 6-10
17 Mains connection
L/N/PE 230 V/50 Hz
18 Wall button 1 (terminals 1-3)
Wall button 2 (terminals 4-6)
Wall button 3 (terminals 7-9)
Wall button 4 (terminals 10-12)
19 Wall button 5 (terminals 1-3)
Wall button 6 (terminals 4-6)
Wall button 7 (terminals 7-9)
Wall button 8 (terminals 10-12),
20 Wall button 9 (terminals 1-3)
Wall button 10 (terminals 4-6),
21*Multifunctional input 1
(terminals 1-3)
Multifunctional input 2
(terminals 4-6)
22 Weather station (terminals 1-2)
Wire assignment: red = 1, black = 2,
yellow and white = not connected
23*Multifunctional input 3
(terminals 3-5)
Multifunctional input 4
(terminals 6-8)
24 Connector for flat-ribbon cable to
front board
25 Microfuse T6.3 A (Drive 1-5)
26 Microfuse T6.3 A (Drive 6-10)
27 Microfuse T630 mA
28 Slot KNX interface
* Supply voltage indoor sensor possi-
ble via MF inputs
(No. 21, terminals 1(+), 2(-) | 4(+),
5(-) and No. 23, term. 3(+), 4(-) | 6(+),
7(-)), max. 400 mA altogether.
20
12
34
5
6
78910 11
12 13 14 15 16 17
18
19
21 22 23
24
25
26
27
28
1 Multifunctional output 1
(potential-free)
2 Multifunctional output 2 (pot.-free)
3 Multifunctional output 3 (pot.-free)
4 Multifunctional output 4 (pot.-free)
5-9Drive group 1-5
10-14Drive group 6-10
15 Outer conductor L1
16 Outer conductor L1
17 Mains connection
L/N/PE 230 V/50 Hz
18 Wall button 1 (terminals 1-3)
Wall button 2 (terminals 4-6)
Wall button 3 (terminals 7-9)
Wall button 4 (terminals 10-12)
19 Wall button 5 (terminals 1-3)
Wall button 6 (terminals 4-6)
Wall button 7 (terminals 7-9)
Wall button 8 (terminals 10-12),
20 Wall button 9 (terminals 1-3)
Wall button 10 (terminals 4-6),
21*Multifunctional input 1
(terminals 1-3)
Multifunctional input 2
(terminals 4-6)
22 Weather station (terminals 1-2)
Wire assignment: red = 1, black = 2,
yellow and white = not connected
23*Multifunctional input 3
(terminals 3-5)
Multifunctional input 4
(terminals 6-8)
24 Connector for flat-ribbon cable to
front board
25 Microfuse T6.3 A (Drive 1-5)
26 Microfuse T6.3 A (Drive 6-10)
27 Microfuse T630 mA
28 Slot KNX interface
* Supply voltage indoor sensor possi-
ble via MF inputs
(No. 21, terminals 1(+), 2(-) | 4(+),
5(-) and No. 23, term. 3(+), 4(-) | 6(+),
7(-)), max. 400 mA altogether.
20
12
34
5 6 7 8 9
10 11 12 13 14
15
16 17
18
19
21 22 23
24
25
26
27
28
EN