EMI C200 Manuale utente

C200 DRIVE SETUP GUIDE
FOR RM-269-129-.3 ELECTRICAL PACKAGE
-C200 Keypad Descriptions
1. The Enter button is used to enter parameter view or edit mode, or to accept a
parameter edit.
2. The Navigation buttons can be used to select individual parameters or to edit
parameter values. In keypad mode, the Up and Down keys are also used to
increase or decrease the motor speed.
3. The Start button (green) is used to start the drive in keypad mode.
4. The Stop / Reset button (red) is used to stop and reset the drive in keypad
mode. It can also be used to reset the drive in terminal mode.
5. The Escape button is used to exit from the parameter edit / view mode or
disregard a parameter edit.
28300 Euclid Avenue Wickliffe, Ohio 44092 • Phone: 216-535-4848

- C200 INDEX/REVERSE BYPASS (RUN VFD VIA KEYPAD ONLY)
1. From main run screen access parameter view by pressing the
Enter button
2. After parameter view mode is entered, scroll through to view the parameters with
the Up and Down keys
3. Scroll to parameter 00.005 where the drive configuration parameter is located for
access
a. When parameter 00.005 is present on the screen press the
Enter button to access edit mode for the parameter
b. When in edit mode for the parameter, the parameter value will start to
blink and the value can be changed by pressing the Up and Down
keys. Change to KEYPAD and press the Enter button
to save.
4. After parameter has been saved press the Escape button to return
to main run screen

- C200 MOMENTARY OR MAINTAINED SIGNALS SELECTION
5. From main run screen access parameter view by pressing the
Enter button
6. After parameter view mode is entered, scroll through to view the parameters with
the Up and Down keys
7. Scroll to parameter 00.011 where the momentary/maintained bit is located for
access
c. When parameter 00.011 is present on the screen press the
Enter button to access edit mode for the parameter
d. When in edit mode for the parameter, the parameter value will start to
blink and the value can be changed Off/On by pressing the Up and
Down keys. Change to Off for Momentary Signals or to On for
Maintained Signals and press the Enter button to save.
8. After parameter has been saved press the Escape button to return
to main run screen
NOTE: If momentary signals are used, the forward and reverse times can be set
via the Forward and Reverse Timer setups in parameters 00.012 and 00.013
respectively

-C200 FORWARD TIMER SETUP (SECONDS WITH MILLISECONDS)
1. From main startup screen access parameter view by pressing the
Enter button
2. After parameter view mode is entered, scroll through to view the parameters with
the Up and Down keys
3. Scroll to parameter 00.012 where the amount of time will be set that the conveyor
will need to move forward when a forward signal is applied to the driver in
momentary signal operation
a. When parameter 00.012 is present on the screen press the
Enter button to access edit mode for the parameter
b. When in edit mode for the parameter, the parameter value will start to
blink and the value can be changed by pressing the
Up and Down keys. When the desired value is displayed
press the Enter button to save.
Note that the value will be set in milliseconds. Example: A value of
10000 will equal 10.000 seconds while a value of 5000 will equal
5.000 seconds
4. After parameter has been saved press the Escape button to return
to main run screen

-C200 REVERSE TIMER SETUP (SECONDS WITH MILLISECONDS)
1. From main startup screen access parameter view by pressing the
Enter button
2. After parameter view mode is entered, scroll through to view the parameters with
the Up and Down keys
3. Scroll to parameter 00.013 where the amount of time will be set that the conveyor
will need to move reverse when a reverse signal is applied to the driver in
momentary signal operation
a. When parameter 00.013 is present on the screen press the
Enter button to access edit mode for the parameter
b. When in edit mode for the parameter, the parameter value will start to
blink and the value can be changed by pressing the
Up and Down keys. When the desired value is displayed
press the Enter button to save.
Note that the value will be set in milliseconds. Example: A value of
10000 will equal 10.000 seconds while a value of 5000 will equal
5.000 seconds
4. After parameter has been saved press the Escape button to return
to main run screen

-C200 PARAMETER SET LIST (ALL OTHERS ARE FACTORY PRESET)
00.001 = 0.00 Hz
00.002 = 60.00 Hz
00.003 = 5.0 s
00.004 = 0.5 s
00.005 = Keypad Ref
00.006 = 1.50 A
00.007 = 1725.0 rpm
00.008 = 230 V
00.009 = 0.85
00.010 = Level 2
00.011 = On
00.012 = 10000 (ms)
00.013 = 10000 (ms)
00.017 = On
00.027 = Last

-C200 FORWARD/REVERSE INTERFACE CONNECTIONS
Illustration above shows connections for (NORMALLY OPEN DRY CONTACTS) from
external equipment.
NOTE: If external equipment is supplying 24VDC signals for index/reverse signals
wire #1 will not be used. Wire according to below:
a. Wire #8 (control wire #99) will go to external equipment 0VDC
(NEUTRAL)
b. Apply 24VDC (HOT) to wire #2 (92) for forward signal above
c. Apply 24VDC (HOT) to wire #3 (93) for reverse signal above
d. Observe parameter 00.011 for Momentary or Maintained signal
selections (Off for Momentary, On for Maintained)