In order to access security
menu 311 should be entered
r0 C0
o1
r1 C2
P1
r2 C3
C5
P2
i1
i5
P5
C4
d0.
d3
d4
d8
-Cn -rE -CP -dE -AL -SC
S.Cd
Cn.s
rE.s
CP.S
dE.S
Al.S
SP.S
GENERAL SETTINGS TEMPERATURE SETTINGS COMPRESSOR SETTINGS DEFROST SETTINGS ALARM SETTINGS SECURITY SETTINGS
Programming Mode
Default
Value
Default
Value
Default
Value
Default
Value
Default
Value
Default
Value
2.0 1
P.YE
P.YE
P.YE
P.YE
P.YE
P.YE
0
0.0
-60.0
3
0.0
150.0 0
10
°C
n.c
3
t.d
10
8
30
d.no
0
Programming Diagram
If this key is pressed
for 2 seconds, SP
message appears on
display and access to
temperature settings.
Temperature value
4.0
SP
Runnig Mode
-18.0
C1 Set Value
-18.1 -18.2 -18.1
Default Value
0.0 If any key is not pressed for 4 seconds, "Running Mode" is entered.
d5
0
d6
1
Operating Temperature
Hysteresis.
It can be adjusted
between 0.1 and 15.0 .
Compressor Power-up
Delay Time
Can be adjusted
between 0 and 199
minutes.
Defrosting Interval.
It can be adjusted between 0
and 199 hours. If 0 is selected,
defrost is never performed.
See d8 parameter.
Defrost Running Time
It can be adjusted between 0
and 199 hours. If 0 is selected,
defrost is never performed.
Defrosting interval Type
Selection.
0 = Defrosting timer ( d0 )
counts during the device is
running.
1 = Defrosting timer ( d0 )
counts during the compressor is
running.
Indicator Value Selection
During Defrost.
0 = Cabin temperature is
displayed.
1 = Displayed if the cabin
temperature is below SP + r0 ,
otherwise SP + r0 is displayed.
When the defrost ends, the
display value does not change
until the cabin temperature falls
below SP + r0 .
P r o b e C a l i b r a t i o n
Can be adjusted between
-25.0 and 25.0
Minimum Temperature
Can be adjusted
between -60.0 and r2
Required Minimum Stop
Duration for Compressor
Can be adjusted between
0 and 199.
Maximum Temperature
Can be adjusted
between r1 and150.0 .
D e c i m a l N o t a t i o n
0 = Without decimal
0.0 = With decimal
Temperature Unit
°C = Celsius
°F = Fahrenheit
Digital Input Relay State
n.o = Will be activated when
switch position is closed.
n.c = Will be activated when
switch position is opened.
Digital Input Behavior
0 = No act.
1 = External alarm is active.
At the end of i7 time, iA
flashes on the screen until the
external alarm is OFF.
2 = External alarm is active.
At the end of the i7 time,
the compressor is stopped
until the external alarm is
turned off and iA flashes
on the display.
3 = Door is open.
Compressor is stopped until
the door closes and id
flashes on the screen when
i7 time is up.
Indicator Selection During
"Running Mode”
t.d = Indicates cabin
temperature.
SP.d = Indicates SP value Compressor Stop Time
In Case of Probe Failure.
Can be adjusted between
0 and 199.
-60.0
150.0
abs
AbS
120
30
15
15
A1
A4
A2
A5
A6
i7
pfa psC iA
___ aH id
___ al
A7
A8
Low Temperature
Alarm Set Value.
Can be adjusted between
-60.0 and 150.0°C.
Hysteresis value is
2°C / 4°F.
Hight Temperature
Alarm Set Value.
Can be adjusted between
-60.0 and 150.0°C.
Hysteresis value is
2°C / 4°F.
Low Temperature
Alarm Type Selection.
No = No alarm
rEL = Dependent on SP
value.
AbS = Independent alarm.
Hight Temperature Alarm
Type Selection.
No = No alarm
rEL = Dependent on SP
value.
AbS = Independent alarm.
Digital Input Delay Time
Can be adjusted between
0and 120 minutes.
Temperature Alarm
Delay Time.
Can be Adjusted
between 0 and 240
minutes.
High Temperature Alarm
Delay Time After Defrost.
Can be adjusted between 0
and 240 minutes.
CAUTION !
During defrost process, alarms will
not be activated.
If the door is open, the high
temperature alarm will not be active.
-Cn Menu Security Level
Non = Menu invisible.
P.YE = Can be modified.
P.np = Read only.
ERROR MESSAGES
Sensor Broken
(Cannot Communicate
with the Sensor ) NTC Sensor Short Circuit External Alarm
High Temperature Alarm Door Open
Measured Temperature
Above the Scale
Move ENDAKEY-RF towards the top left of the
device in direction 1 .
If this key is pressed
for 4 seconds,
“Programming Mode”
is entered.
First time pressed any of the
keys, temperature set value
appears by flashing.
And, temperatures set value can be adjusted by using keys.
Accessing to "Running Mode" from "Programming Mode" :
if no key is pressed within 30 seconds during “Programming Mode”,
data is stored automatically and "Running Mode" is entered.
Alternatively, by pressing key for 4 seconds, data is stored and
"Running Mode" is entered.
If this button is pressed for 2 seconds, device turned ON or OFF.
If this key is pressed for 1 second while the alarm buzzer is active,
buzzer is turned OFF. If this key is pressed for 4 seconds, the manual
defrost mode is entered or exited.
Required Minimum
Running Duration for
Compressor
Can be adjusted between
0 and 199.
Compressor Running
Time In Case of Probe
Failure.
Can be adjusted between
0 and 199.
Defrost Time Performed at
Power-up
d.no = Defrost not performed at
power-up
d.yE = Defrost performed at
power-up
Defrost Power-up Start Delay
Time
Can be adjusted between 0 and
199 minutes. Will be valid if ;
d4 = d.yE
While in a parameter menu, if
key is pressed for 2 seconds
“Programming Mode" is entered.
High Temperature Alarm
Delay Time After Power-up.
Can be adjusted between
0 and 240 minutes.
SETTING UP THE PARAMETERS
If key is pressed, the current value of the parameter appears by
flashing on the display.
After the setting up the parameters, if set key is pressed again,
adjusted parameter name appears on display.
By using “UP” or “DOWN” navigation keys, selected
parameter can be adjusted to the desired value.
During a parameter adjustment, If one of the or navigation key is
pressed continuously for 0.6 seconds, adjusted value to be changed increases or
decreases rapidly.
If it continues to press for longer than 0.6 seconds, hundered digits will increases or
decreases rapidly. If the key released and wait for a second, then process returns
to the units digit.
r2 50.0 49.9 50.0
Whilst in S.Cd = 0
parameter, by pressing and
held down key and
by pressed key for 3
seconds, dEF parameter is
displayed and the device
returns to default settings.
-rE Menu Security Level
Non = Menu invisible.
P.YE = Can be modified.
P.np = Read only.
-CP Menu Security Level
Non = Menu invisible.
P.YE = Can be modified.
P.np = Read only.
-dE Menu Security Level
Non = Menu invisible.
P.YE = Can be modified.
P.np = Read only.
-AL Menu Security Level
Non = Menu invisible.
P.YE = Can be modified.
P.np = Read only.
SP Menu Security Level
P.YE = Can be modified.
P.np = Read only.
If the pressed for 4 seconds, device switch to "Programming Mode". If you keep pressing the key for 6
seconds, then the message H.rd appears on display and device is moved to the reading position from the
ENDAKEY. In this case the device waits for the parameters to be read from ENDAKEY. In this case,
ENDAKEY should touching the upper left the corner of device and pressing the button on the ENDAKEY.
Parameters reading is performed with ENDAKEY the PyE is shown before return to the operating mode. If
reading is not performed, the device waits for 1 minute and returns to the "Running Mode".
Programing From the Device to ENDAKEY-RF
Programing With ENDAKEY-RF
If the button on the ENDAKEY is pressed and ENDAKEY will transfer the parameters to the device then
the PyE message is shown. And the device switches to the "Running Mode".
Measured Temperature
Below the Scale High Temperature Alarm
2 / 2