Endon YG-865-SS Manuale utente

1
The Light pack contains:
Light fitting and mounting bracket.
Terminal connection block(s).
The following tools may be required:
Selection of cross and flat head screwdrivers.
Electric drill and assorted drill bits.
Wire strippers.
Electrical insulation tape.
INSTRUCTION MANUAL
This product DOES NOT have special protection against the ingress of water. It is ONLY
suitable for use in porches if it is not exposed to water ingress.
This product is only suitable for connection to a 240V~50Hz supply in accordance with current IEE
wiring Regulations and should be installed in accordance with local Building Regulations and is for
Domestic indoor ceiling use only and is not suitable for a Bathroom location.
The light fitting should be connected to a lighting circuit protected by a 5 amp fuse (or a 6 amp
miniature circuit breaker).
If in doubt we recommend you contact a qualified electrician. Before installing your light fitting
always:
Switch off the mains supply and remove the appropriate fuse or switch off the appropriate circuit
breaker before commencing installation.
Ensure that no one else has access that would enable the supply to be inadvertently reconnected.
Never fit bulbs of a higher wattage or of a type other than those specified on the label as this may
cause overheating and damage the fitting.
When fixing to the mounting surface ensure that the fixings used are appropriate for the mounting
surface on which they are being used.
The bulbs become hot during use so please switch off and allow 10 minutes to cool before replacing
bulbs or cleaning the fitting.
IMPORTANT: To achieve maximum corrosion resistance the surface of the Stainless Steel must be
kept clean. Surface contamination and the formation of deposits are critical factors which may lead
to drastically reduced life. An example is salt deposits from marine conditions. Careful cleaning with
soap or a mild detergent and warm water followed by a clean water rinse and finally wiping dry is
usually adequate for most S/S items used in the domestic environment. Care must be taken to turn
off the mains supply until the cleaning process has been completed and the fitting is completely dry.
If any modification is made it will invalidate the warranty and may render the product unsafe.
Before you start
Please read these instructions carefully before fitting your new light and retain for reference.
Make sure that there are no pipes or cables beneath the mounting surface.
Check the packaging and make sure that you have all the required parts.
Follow each assembly step in order to prevent incorrect assembly.
Make sure all screws / nuts, including electrical connections etc are fully tightened before use.
This type of Light Fitting may be connected to a Dimmer if a Tungsten incandescent bulb is used. If
a CFL type bulb is fitted then these cannot (generally) be controlled by a dimmer.
YG-865-SS – Single pendant
Safety Warnings

2
Assembly/ User Instructions
These assembly diagrams are intended as a guide – if in doubt consult a qualified electrician.
N210 110
Diagram A
1. Decide on the position of the light fitting / or remove existing
light fitting. Take a note of the position of the electrical
connections. Ensure there is a solid mounting surface,
preferably a wooden joist or joist bridge to support the
weight of the light fitting.
2. Diagram A. Remove the (2x) domed nuts and use the back
housing (1) as a template to mark the screw holes. Mark the
screw holes, bring the supply cable through the back
housing and then secure it to the ceiling with appropriate
screws fixings (2). Make sure that the threaded bolts 3
remain in their position in the back housing.
3. Diagram B. Assemble the decorative finial (3) and connect
it to the lower part of the cage.
4. If you want to reduce the overall length of the fitting it is
essential that this is done before the fitting is mounted to
the ceiling and / or connected to the mains supply. Remove
the appropriate number of chain links as shown until the
desired length is reached. The cable must now be
shortened and the excess cable cut and re-connected to the
terminal block. Make a note of the position of the cables in
the terminal block. Cut off the excess cable and re-connect
to the terminal block. NOTE: The electric cable must
always be longer than the Chain to prevent strain being
placed on the cable. If you are unsure about your
ability to do this, we recommend you contact a qualified
electrician.
5. Support your fitting and connect the house wiring to the
terminal block (4) – see wiring details. NOTE: This is a
Class I fitting and must be earthed. The 4th terminal block
connector is used for the “loop” wires of the “Ring Circuit”.
There may be more than one set of cables in the “loop”
connections. If there is a “Ring Circuit” and you do not
understand the connections you must consult an electrician.
Any loose terminal blocks –not secured to ceiling cup -
should always be covered with 2 layers of good quality
insulation tape.
6. Secure the unit back onto the back housing using the
dome nuts removed in 2 above. Make sure that all the
internal cables and connections are inside the back housing
taking care not to trap or strain the internal cables.
7. Fit the bulb (5) into the lamp holder. NOTE; Never fit a
bulb of a higher wattage or of a type other than that
specified on the label (as this may cause overheating
and damage the fitting).
8. Fit the cage (6) onto the lid and secure with the 3 x nuts (7).
9. Turn on the power and test.
Endon lighting
LS9 0SE
20151218
Diagram B
Wiring Details
Indice
Manuali Illuminazione del paesaggio popolari di altre marche

Cooper Lighting
Cooper Lighting MCGRAW-EDISON WBG Manuale utente

Cooper Lighting
Cooper Lighting Invue 42 - 175W Manuale utente

Saxby Lighting
Saxby Lighting Islay 68784 Manuale

LIGMAN
LIGMAN EU-10016-3 Manuale utente

Cooper Lighting
Cooper Lighting McGraw-Edison ZD Credenza Manuale utente

LIGMAN
LIGMAN KI-60475 Manuale utente