Endress+Hauser Promag Manuale utente


EA01238D
Endress+Hauser 3
Kit wireless antenna for extended range
Promag, Promass 300, 500, 500 – digital
Table of contents
1 Overview of accessory ............................................................. 4
2 Authorized installation personnel .................................................. 4
3 Safety instructions ................................................................ 4
4 Symbols used ..................................................................... 5
5 Tools list .......................................................................... 6
6 Promag, Promass 300, 500 ........................................................ 6
7 Promag, Promass 500 – digital .................................................... 9

EA01238D
4 Endress+Hauser
1 Overview of accessory
The Installation Instructions apply to the following accessories:
Order code Original accessory Contents
71351317 1 × wireless antenna set 1 × antenna, 1 × antenna feedthrough,
1 × antenna cable, internal 1 × antenna cable
external, 1 × angle bracket
2 Authorized installation personnel
Authorization to carry out installation depends on the measuring device's approval type. The
table below shows the authorized group of people in each case.
Whoever carries out the installation has full responsibility to ensure that work is carried
out safely and to the required quality standard. He/she must also guarantee the safety of
the device following installation.
Measuring device approval Authorized installation personnel 1)
Without approval 1, 2, 3
With approval (e.g. IECEx) 1, 2, 3
For custody transfer 4
1) 1 = Qualified specialist on customer side, 2 = Service technician authorized by Endress+Hauser,
3 = Endress+Hauser (return measuring device to manufacturer)
4 = Check with local approval center if installation/modification must be performed under supervision.
3 Safety instructions
• Only use original parts from Endress+Hauser.
• Comply with national regulations governing mounting, electrical installation,
commissioning, maintenance and repair procedures.
• The following requirements must be met with regard to specialized technical staff for the
mounting, electrical installation, commissioning, maintenance and repair of the measuring
devices:
– Specialized technical staff must be trained in instrument safety.
– They must be familiar with the individual operating conditions of the devices.
– In the case of Ex-certified measuring devices, they must also be trained in explosion
protection.
• The measuring device is energized! Risk of fatal injury from electric shock. Open the
measuring device only when the device is deenergized.
• When using Ex-certified measuring devices: open device only when in a deenergized state
(allow 10 minutes to elapse after switching off the power supply) or in environments which
do not have a potentially explosive atmosphere.

EA01238D
Endress+Hauser 5
• When using measuring devices in safety-related applications in accordance with IEC 61508
or IEC 61511: following installation, re-commission the device in accordance with the
Operating Instructions. Document the installation.
• Before removing the device: set the process to a safe state and purge the pipe of dangerous
process substances.
• Hot surfaces! Risk of injury! Before commencing work: allow the system and measuring
device to cool down to a touchable temperature.
• In the case of devices in custody transfer, the custody transfer status no longer applies once
the seal has been removed.
• The Operating Instructions for the device must be followed.
• Risk of damaging the electronic components! Ensure you have a working environment
protected from electrostatic discharge.
• After removal of the electronics compartment cover: risk of electrical shock due to missing
touch protection!
Turn instrument off before removing internal covers.
• Modifications to the measuring device are not permitted.
• Only open housing for a brief period. Avoid the penetration of foreign bodies, moisture or
contaminants.
• Replace defective seals only with original seals from Endress+Hauser.
• If threads are damaged or defective, the measuring device must be repaired.
• Threads (e.g. of the electronics compartment cover and connection compartment cover)
must be lubricated if an abrasion-proof dry lubricant is not available. Use acid-free, non-
hardening lubricant.
• If, during installation, spacing is reduced or the dielectric strength of the measuring device
cannot be guaranteed, perform a test on completion of the work (e.g. high-voltage test in
accordance with the manufacturer's instructions).
• Service plug:
– Do not connect in explosive atmospheres.
– Only connect to Endress+Hauser service devices.
• Observe the instructions for transporting and returning the device outlined in the Operating
Instructions.
If you have any questions, please contact your Endress+Hauser service organization.
4 Symbols used
4.1 Symbols for certain types of information
Symbol Meaning
Permitted
Procedures, processes or actions that are permitted.
Forbidden
Procedures, processes or actions that are forbidden.

EA01238D
6 Endress+Hauser
Symbol Meaning
Tip
Indicates additional information.
1.
,
2.
,
3.
… Series of steps
5 Tools list
3 mm 30 mm 0.5 × 3.5 mm T20
6 Promag, Promass 300, 500
6.1 Mounting the antenna feedthrough
1 → 2 →
3.
Nicht unter
Spannung öffnen
Do not open when
energized
Ne pas ouvrir
sous tension
Power
I/O
N
i
c
ht
u
n
t
e
r
a
r
e
ö
f
f
n
e
n
2.
1. 3 mm
D
i
s
p
l
a
y
+E
ESC
–
Nicht unter
Spannung öffnen
Do not open when
energized
Ne pas ouvrir
sous tension
Power
I/O
+E
ESC
–
1.
1.
2.
3.
N
i
c
ht
u
n
t
e
r
a
r
e
ö
f
f
n
e
n
3 → 4 →
D
i
s
p
l
a
y

EA01238D
Endress+Hauser 7
5 → 6 →
30 mm
4 Nm
1.
2.
3.
7 →
8 → 9 →
+E
ESC
–
Nicht unter
Spannung öffnen
Do not open when
energized
Ne pas ouvrir
sous tension
Power
I/O
+E
ESC
–
2.
3.
2. 1.
N
i
c
ht
u
n
t
e
r
a
r
e
ö
f
f
n
e
n
D
i
s
p
l
a
y
+E
ESC
–
Nicht unter
Spannung öffnen
Do not open when
energized
Ne pas ouvrir
sous tension
Power
I/O
N
i
c
ht
u
n
t
e
r
a
r
e
ö
f
f
n
e
n
3 mm
1.
2.5 Nm (1.8 lbf ft)
2.
3.

EA01238D
8 Endress+Hauser
10
6.2 Mounting the wireless antenna with cable
3.
1.
2.
5.
4.
For detailed information on the electrical connection, see the "Electrical connection"
section of the Operating Instructions for the device.
For detailed information on commissioning, see the "Commissioning" section of the
Operating Instructions for the device.

EA01238D
Endress+Hauser 9
7 Promag, Promass 500 – digital
7.1 Mounting the antenna feedthrough
1 → 2 →
T20
1.
2.
-+-
ESC
2.
1.
3 →
2.
-+-
ESC
1.
4 → 5 →
30 mm
4 Nm

EA01238D
10 Endress+Hauser
6 →
7 → 8 →
2.
-+-
ESC
1.
2.
T20
1.
2.
9
Altri manuali per Promag
1
Questo manuale è adatto per i seguenti modelli
3
Indice
Lingue:
Manuali Antenna popolari di altre marche

Alfa Network
Alfa Network APA-L01 Manuale utente

Naval
Naval PR-422CA Manuale utente

Feig Electronic
Feig Electronic ID ISC.ANTH200/200 Series Manuale utente

TERK Technologies
TERK Technologies TV44 Manuale utente

Directive Systems & Engineering
Directive Systems & Engineering DSE2324LYRMK Manuale utente

HP
HP J8999A Manuale utente