Enerset Cube Manuale utente

Thermostat model: Cube
Instruction
INSTALL
02
01
03
04

01 Introduction....................................................................................................
03 Installation......................................................................................................
04 Wiring Instruction..........................................................................................
05 Thermostat Symbols.....................................................................................
06 WiFi Connection.................................
08 Troubleshooting.................................
09 Dimension...........................................
07 Function and Operation.....................
02 Technical Specifications...............................................................................
Table of
Contents
01
02
05
01
03
04
07
13
14
7.1 On/Off..................................................
7.2 Temporary Override Temperature....
7.3 Key-Lock.............................................
7.5 Holiday Mode......................................
07
07
08
08
7.6 Hold Mode...........................................
7.7 Edit Setting.........................................
7.8 Setup...................................................
7.9 Open Window detection....................
7.4 Set the Time........................................
09
09
12
07
10
APP
for Cube

TECHNICAL SPECIFICATIONS
INTRODUCTION INSTALLATION
at comfortable temp whilst minimizing energy use. Install the app on your
Cube
01
02
Supply voltage: 220-240V 50Hz
<1W
IP class: IP21 Insert the back panel into wall box with
provided screws.
Align top part of front panel and back panel
to fit these two parts. Then fix them with
screw.
Step 3:
of the thermostat to get the front panel.
Step 1:
Connect the thermostat according to the
Step 2:
Step 4:

Down
UP
Power
Confirm
Return
Clock
Period
Temperature
On/Off
WiFi
Day indicator
THERMOSTAT SYMBOLS
03 04
WIRING INSTRUCTION
MAX LOAD: 16A
SENSOR
L1N1 N L
FLOOR
SENSOR
POWER
85V-265V
50/60Hz
IP 21
N1 NLL1 S2 COM S1
POWER
FLOOR SENEOR
Note:

05 06
WIFI CONNECTIONION
and click “Done”.
create family.
thermostat,when the WIFI icon flash quickly, please click
“Press to connect”.
Step 1: Scan the QR code or download the Warmme
from APP store/Google browser.
Step 2: Register and log in with mobile number/
email address in the APP.
Policy and Service agreement” before
Step 4: Click “Add Device” or “+” on the
top-right to add device.
Step 6: Enter Wifi password, and click “Confirm”.
set temperature etc. at the control interface.
!
Step 7: If device added successfully, you can change the
device name and set region, then, click “Done”.
and check the Wifi signals, then, use the “AP mode” in the
top right to connect again.

07 08
7.4 Set the Time
On the actual temp interface, Press and ‘Time’ will be displayed.
Press to set day.
Press to set hour.
Press to back to the actual temp interface.
7.5 Holiday Mode
FUNCTION AND OPERATION
7.1 On/Off
Press to turn On/Off.
Note:
temp when it is Off.
7.2 Temporary Override Temperature
The temporary override temp is only valid at the current event and it will not be saved.
On the actual temp interface, press to set temporary override temp.
Press to confirm and back to the actual temp interface.
interface, press and hold for 3 seconds to lock or unlock all the keys.
7.3 Key-Lock
On the actual temp interface, Press and ‘Time’ will be displayed.
Press to select ‘Holiday’.
Press to set holiday days.
Press to set temp.
Press to confirm and back to the actual temp interface.
* Set the holiday days to zero or double press to cancel Holiday Mode.

09 10
7.6 Hold Mode
On the actual temp interface, Press and ‘Time’ will be displayed.
Press to select ‘Hold’.
Press to set Hold ON.
Press to set temp.
Press to confirm and back to the actual temp interface.
* Set hold OFF or double press to cancel Hold Mode.
7.7
thermostat runs according to the parameters of Edit.
On the actual temp interface, press and ‘Time’ will be displayed.
Press or to select ‘Edit’.
Press or to select a day.
Press or to select a event.
Press or to set the temp.
7.8 Setup
Day
Wak
Default parameters
e Leave Back Sleep
Mon-Fri
07:00 22.0°C
08:30 19.0°C
17:00 22.0°C
22:00 19.0°C
Sat/Sun 08:00 22.0°C 08:30 22.0°C 17:00 22.0°C 22:00 19.0°C
On the actual temp interface, press and ‘Time’ will be displayed.
Press or to select ‘Setup’.
Press to enter Setup.
Each parameter can be accessed by pressing and adjust the values as required.

11 12
Calibrate the temp detected by room sensor or floor sensor.
3. Sensor select:
Room sensor: Run by room sensor.
Floor sensor: Run by floor sensor.
Both sensors: Run by room sensor with floor temp limit.
4. Floor temp limit: If you choose both sensors, floor temp limit must be set to protect floor.
5. Temp unit: °C and °F can be selected.
6. Output delay:
7. Temp tolerance: The value is 1°C. The thermostat start to work when the actual temp is
1°C lower than set temp and stop to work when the actual temp is 1°C higher than set temp.
8.Brightness:
9.Energy use:
10. Schedule:
7: each day from Mon to Sun can be set individually.
5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually.
that the required temp has already been reached when the next event begins.
12. Reset: All parameters are restored to default values.
room temp plummets.
7.9
No.
Name
1 Temp calibra on
2 An -frozen func on
An -frozen
Sensor select(Room
4
Floor temp limit
5
Temp unit
6 Output delay
9
10
11
Schedule
12
Default
0.0°C
0.0°C
ON
5.0°C
30 °C
°
C
1
Ranges
-5.0°C -- 5.0°C
-5.0°C -- 5.0°C
ON/OFF
5.0°C -- 15.0°C
20°C -- 50°C
°
C/
°F
Floor sensor
Room sensor
An -frozen
switch
Temperature
3 ,Floor) Floor temperature
sensor
Room temperature sensor
Floor temperature sensor
Both sensors
0 S
7Temp tolerance
8Brightness
Energy use
Factory reset
°C
80%
0W
5+1+1
OFF
Back
0 S/30 S/60 S/90 S
0.5 /1 /2 /3°C°C°C°C
0%--100%
0W-4500W
ON/OFF
7/5+1+1
Yes/Back

E1: Room sensor error.
E2: Floor sensor error.
86
86
16 26 59
51
51
13 14
DIMENSION(MM)
TROUBLESHOOTING
Indice
Altri manuali Enerset Termostato