entegris Optimizer ST2 Guida

MICROCONTAMINATION CONTROL |MANUAL
Optimizer®ST2 Filter Manifold
Installation and use manual

OPTIMIZER ST2 FILTER MANIFOLD
1Entegris, Inc | Installation and Use Manual
TABLE OF CONTENTS
—
Introduction ....................................................................... 2
Specifications .................................................................... 2
Ordering Information ..................................................... 2
Manifold and Filter Parts ................................................ 3
Dimensions ........................................................................ 4
Mounting Plate (Common to all Types) ................... 4
Tube Type Manifold
Part Number AMVT***01 ................................... 4
Flowell 60 Elbow Type Manifold
Part Number AMVXL22KT .................................. 5
Part Number AMVXL32KT .................................. 6
Part Number AMVXL42KT .................................. 7
Flowell 80EX Elbow Type Manifold
Part Number AMVZL22KT .................................. 8
Part Number AMVZL32KT .................................. 9
Part Number AMVZL42KT ................................ 10
Safety Instructions .......................................................... 11
Preparation for Installing the
Optimizer ST2 Manifold ................................................ 11
Installing the Optimizer ST2 Manifold ...................... 12
Attaching and Removing the Filter ............................ 16
Preparing the Line Before Replacing the Filter .... 16
Preparing the Filter to be Replaced ........................ 16
Removing the Filter or Flushing Shell .................... 16
Attaching the Filter or Flushing Shell ........................ 18
Filter Startup .................................................................... 20
Replacing the O-rings .................................................. 21
Removing the O-rings ................................................ 21
Attaching the O-rings .................................................. 21
Limited Warranty ............................................................ 22
For More Information ................................................... 22
Terms and Conditions of Sale ..................................... 22

2
OPTIMIZER ST2 FILTER MANIFOLD
Installation and Use Manual | Entegris, Inc.
INTRODUCTION
—
The Optimizer®ST2 filter manifold is designed for
use with Optimizer point-of-use (POU) liquid filters
to minimize contamination risk when handling filter
cartridges. Using Entegris’ Connectology®technology,
the Optimizer filter quickly connects and seals to the
ST2 manifold, which enables rapid filter change-outs
without tools or draining. By limiting hazardous
chemical handling during installation, the filter mani-
fold speeds up installation and reduces downtime
while also increasing operator safety.
CAUTION: To reduce the safety risk of chemical
leakage, carefully follow these instructions.
SPECIFICATIONS
—
Materials Metal plates Stainless steel
Release tub Polyacetal
Connectors PFA
O-rings on
manifold
OM: Kalrez®
Connections Tube, Flowell®60, Flowell 80EZ
(See part number table for sizes.)
Maximum
operating
conditions
Maximum operating pressure:
0.39 MPa (3.9 bar, 57psi) at 25°C (77°F)
Maximum operating temperature:
40°C (104°F)
ORDERING INFORMATION
—
OPTIMIZER ST2 MANIFOLD
Quantity: 1 each/box
Tube Type (standard size)
Part number Inlet/outlet Vent port
AMVT442K1 12.7 mm (⁄") tube 6.35 mm (⁄")
AMVT332K1 9.53 mm (⁄") tube 6.35 mm (⁄")
AMVT222K1 6.35 mm (⁄") tube 6.35 mm (⁄")
Flowell 60 Elbow Type
AMVXL42KT 12.7 mm (⁄") 6.35 mm (⁄")
AMVXL32KT 9.53 mm (⁄") 6.35 mm (⁄")
AMVXL22KT 6.35 mm (⁄") 6.35 mm (⁄")
Flowell 80EZ Elbow Type
AMVZL42KT 12.7 mm (⁄") 6.35 mm (⁄")
AMVZL32KT 9.53 mm (⁄") 6.35 mm (⁄")
AMVZL22KT 6.35 mm (⁄") 6.35 mm (⁄")
Replacement O-ring
Part number Description
10456J Kalrez O-ring for ST2 manifold
OM version, 10/bag
CAUTION: If higher pipeline tension is expected, it is
recommended to use a double O-ring combination
of the OM manifold and OF filter.

OPTIMIZER ST2 FILTER MANIFOLD
3Entegris, Inc | Installation and Use Manual
MANIFOLD AND FILTER PARTS
—
Manifold
Outlet
Inlet
Vent
Release tab
Lever
Filter guide
Filter
Tab

4
OPTIMIZER ST2 FILTER MANIFOLD
Installation and Use Manual | Entegris, Inc.
DIMENSIONS
—
MOUNTING PLATE (COMMON TO ALL TYPES)
TUBE TYPE MANIFOLD (PART NUMBER AMVT***01)
2X Ø6.0 mm
(0.24")
42.5 mm
(1.67")
50.8 mm
(2.0")
65.0 mm
(2.56")
19.0 mm
(0.75")
4X Ø4.5 mm (0.18")
R 3.0 mm (0.12")
23.0 mm
(0.91")
6.5 mm (0.26")
9.2 mm
(0.36")
22.2 mm
(0.87")
2.0 mm (0.08")
Top View
Front View Side View
104.5 mm
(4.11")
40.8 mm
(1.60") 62.0 mm
(2.44")
139.1 mm
(5.48")
25.3 mm
(1.00")
25.3 mm
(1.00")
95.5 mm
(3.76")
150.0 mm
(5.91")
32.4 mm
(1.27")
16.0 mm
(0.63")
102.8 mm
(4.05")
205.0 mm (8.07")
174.0 mm
(6.85")
126.0 mm
(4.96")

OPTIMIZER ST2 FILTER MANIFOLD
5Entegris, Inc | Installation and Use Manual
DIMENSIONS (CONTINUED)
—
FLOWELL 60 ELBOW TYPE MANIFOLD (PART NUMBER AMVXL22KT)
Top View
Front View Side View
104.5 mm
(4.11")
40.8 mm
(1.60") 62.0 mm
(2.44")
139.1 mm
(5.48")
25.3 mm
(1.00")
25.3 mm
(1.00")
95.5 mm
(3.76")
60.0 mm
±2 mm
(2.36"
±0.08") 32.4 mm
(1.27")
16.0 mm
(0.63")
102.8 mm
(4.05")
205.0 mm (8.07")
174.0 mm
(6.85")
Outlet
Inlet
Vent

6
OPTIMIZER ST2 FILTER MANIFOLD
Installation and Use Manual | Entegris, Inc.
DIMENSIONS (CONTINUED)
—
FLOWELL 60 ELBOW TYPE MANIFOLD (PART NUMBER AMVXL32KT)
Top View
Front View Side View
104.5 mm
(4.11")
40.8 mm
(1.60") 62.0 mm
(2.44")
139.1 mm
(5.48")
25.3 mm
(1.00")
25.3 mm
(1.00")
95.5 mm
(3.76")
60.0 mm
±2 mm
(2.36"
±0.08") 32.4 mm
(1.27")
16.0 mm
(0.63")
102.8 mm
(4.05")
205.0 mm (8.07")
174.0 mm
(6.85")
98.0 mm
±2 mm
(3.86"
±0.08")
78.0 mm
±2 mm
(3.07"
±0.08")
Outlet
Inlet
Vent

OPTIMIZER ST2 FILTER MANIFOLD
7Entegris, Inc | Installation and Use Manual
DIMENSIONS (CONTINUED)
—
FLOWELL 60 ELBOW TYPE MANIFOLD (PART NUMBER AMVXL42KT)
104.5 mm
(4.11")
40.8 mm
(1.60") 62.0 mm
(2.44")
139.1 mm
(5.48")
25.3 mm
(1.00")
25.3 mm
(1.00")
95.5 mm
(3.76")
60.0 mm
±2 mm
(2.36"
±0.08") 32.4 mm
(1.27")
16.0 mm
(0.63")
102.8 mm
(4.05")
205.0 mm (8.07")
174.0 mm
(6.85")
98.0 mm
±2 mm
(3.86"
±0.08")
78.0 mm
±2 mm
(3.07"
±0.08")
Outlet
Inlet
Vent
Side ViewFront ViewFront View
Top ViewTop View

8
OPTIMIZER ST2 FILTER MANIFOLD
Installation and Use Manual | Entegris, Inc.
DIMENSIONS (CONTINUED)
—
FLOWELL 80EZ ELBOW TYPE MANIFOLD (PART NUMBER AMVZL22KT)
104.5 mm
(4.11")
40.8 mm
(1.60") 62.0 mm
(2.44")
139.1 mm
(5.48")
25.3 mm
(1.00")
25.3 mm
(1.00")
95.5 mm
(3.76")
85.0 mm
±2 mm
(3.45"
±0.08")
Front View
42.5 mm
(1.67")
73.0 mm
(2.87")
Top View
Side View

OPTIMIZER ST2 FILTER MANIFOLD
9Entegris, Inc | Installation and Use Manual
DIMENSIONS (CONTINUED)
—
FLOWELL 80EZ ELBOW TYPE MANIFOLD (PART NUMBER AMVZL32KT)
104.5 mm
(4.11")
40.8 mm
(1.60") 62.0 mm
(2.44")
139.1 mm
(5.48")
25.3 mm
(1.00")
25.3 mm
(1.00")
95.5 mm
(3.76")
79.0 mm
±2 mm
(3.11"
±0.08")
Front View
73.0 mm
(2.87")
42.5 mm
(1.67")
89.0 mm
(3.50")
Top View
Side View
98.0 mm
±2 mm
(3.86"
±0.08")
Indice
Altri manuali entegris Sistema di filtraggio dell'acqua