EntryVue AC-500 Keypad User Manual
EM Metal Password Access Controller
4.1 Modify administrator password:
Press
Note: the administration password is between 6 - 8 numbers.
please be careful when entering.
Automatically adding, the user ID automatically
generated by this machine, the range is 1 - 2000,
and search from small to large.
Note: input ID digits of 1-4 digits, The range is 1 - 2000,
numbers such as 1,01,001,0001 ID number all expressed 1.
4.2 Add user:
4.3 Delete user
4.2.1 Add multiple cards:
The new password # Repeat he new password #
5.1 Card modify password:
Press
Press
Note: applicable to a card or card-less users, if the
user password is "1234", must use card to modify
Reading card
Press
4.2.2 Add designated card Number:
, ...,
, ...,
Reading card Reading card
4.2.5 Add designated ID number and password:
Press ...
ID No # password # ID No # password #
Press
Eight card number # Eight card number #
4.3.1 Delete swipe card
Press
4.3.2 Delete Designated card Number:
...
, ...,
Reading card Reading card
Press
Eight card number # Eight card number #
4.2.3 Add designated ID Number swipe card:
, ...
,Press
ID number # ID number #Reading card
Reading card
4.2.4 Add designated ID number and card number:
, ...
,Press
ID number # ID number #Eight card number #
Eight card number #
Adding card user will automatically generate a default
password "1234", but this password can not open the door,
the password is only for a user to change to a new password.
Note: applicable to number card users, password and
card are unrelated, input a four digit code, but not "1234"
4.3.3 Delete Designated ID Number:
Press
4.3.4 Delete all:
...
Repeat the new password
ID No # ID No #
Press
20000
6.1 External alarm and built-in buzzer alarm at the same time
Swipe or press
Valid card Administrator password #
5.2 User ID number modify password
ID No Old password
Repeat the new password
Press , doors open
5.4 Password open:
, doors open
(stop alarm)
6.2 Close door alarm tips
Close the door, or swipe card , or input
Valid card
Administrator password #
, Can stop alarm
5.5 Card + Password open:
, doors open
5.3 Card open:
Reading card
Reading card
4.7.1 Shielding of the function (factory default):
0~99
4.4 Door opening method setting:
4.4.1 Card open:
4.5 Unlock time setting:
Press
Press
4.4.2 Card + Password open:
Press
4.4.3 Card or Password open:(Factory default)
Press
Note: The lock time range "0 to 99 seconds ",
the factory default is 5 seconds
4.6 Alarm time setting:
Press
Note: The alarm time ranges from 0 - 3 minutes,
the factory default is 1 minute
Press
Press
4.7.2 Open the function:
Open the function, two possibilities:
4.8.1 Normal mode (factory default)
Press
Press
4.8.2 Lock mode:
The system will lock and alarm after a ten minute
continuous brush of an invalid keycard. The system will
also alarm after a continuous entry of a wrong password.
4.7.2.1 If the door is not closed properly for 1 minute,
the built-in buzzer alarm will sound off.
4.7.2.2 If the doors are unlock for 20 seconds after the
doors are opened, or if the doors are forced to
open, the built-in buzzer alarm will soud off.
4.7 Magnetic Alarm Function setting:
4.8 Security mode setting
0~3
7. Acousto-optic instructions
Operation
state
Standby
Buttons
Success
Failure
Into
programming
Set condition
Exit
programming
Unlock
Alarm
Red Light
Slow
flashing
Off
On
On
Slow flash
Off
Fast flashing
Green Light
Off
On
Off
On
Off
On
Off
Buzzer
Di
Di-
DiDiDi
Di-
Di-
Di-
Alarm sound
Note
Indicator is
orange