Installation
QUALIFIED INSTALLERS ONLY
hi-limit switCh: (For use with ipi FireplaCes only)
Supplied with the HDK is a Hi-Limit switch assembly that must be installed if the HDK is being used on
an IPI C44 replace. Installation of the Hi-Limit switch is easy and only takes a couple minutes.
Step 1: Prior to installation of the C44, remove the
safety screen assembly. Next, remove the front cover
using a T20 screwdriver (see Figure 8).
Step 2: Using a T20 screwdriver, loosen the left
mounting screw of the IFC and slide the Hi-Limit
Switch Bracket onto the IFC as shown. Next, retighten
the left mounting screw (see Figure 9).
Note: Placement of the Hi-Limit switch is not arbitrary
and must be correct for proper operation. When
correctly installed, the bracket should contact both the
mount ange and left side of the IFC (Figure 9).
Step 3: Using a small at-blade screwdriver, loosen
the terminals on the IFC ON/OFF plug (X4 on IFC)
and remove the jumper wire (see Figure 10). Next,
insert the wires from the Hi-Limit Switch and re-
tighten the terminals. There is no polarity to the
wires so they cannot be wired backwards.
Step 4: The Hi-Limit Switch installation is now complete. The front cover and safety screen may now
be re-installed on the C44.
Note: In rare circumstances, when the HDK is installed in an adjoining room, a large difference in
room pressure may temporarily cause the HDK to reverse ow. If this occurs over a prolonged period of
time the Hi-Limit Switch will automatically turn off the C44 to protect the IFC. Once the C44 has cooled
sufciently (approx. 10-15 minutes) it will automatically re-start and continue normal operation.
Figure 8. C44 - Front Cover Removal
Figure 9. Hi-Limit Switch - Correct Placement
Figure 10. Hi-Limit Switch - Correct Wiring
Long Wire
Short
Wire