4
1. Detection in Standard Mode:
The standard mode is very praccal and allows the simultaneous
detecon of electric and magnec elds and high frequencies with
or without sound.
The device makes radiaon easily "visible" therefore making the
sources more easily idenable.
It can also be used to verify the protecon soluons that have been
put in place to reduce exposure to waves.
1. Briey press the "on-o" buon to switch the unit to standard
mode.
2. Hold the detector with your arm slightly extended forward.
3. Move around slowly to detect electromagnec elds. The
device performs a new detecon every two seconds.
NB: To acvate or deacvate the sound, press and hold on the select
buon.
2. Detection in FULL HF Mode:
The FULL HF mode enables an enhanced sensivity detecon that corresponds to the tolerance thresh-
olds of electro-sensive people.
In Standard Mode, high-frequencies are detected by 8 LEDs. In FULL HF Mode there are 24 LEDs for
greater accuracy. The LEDs light up from LEFT to RIGHT from the BOTTOM to the TOP.
The detected high-frequency sound corresponds to a FINE ACOUSTIC ANALYSIS which is very useful.
This allows the sources to be idened by a sound proporonal to the modulated frequency. In other
words, this funcon allows the ear to dierenate between dierent sources of radiaon. For exam-
ple, if it is from the WiFI, a DECT phone, or an antenna. However, if the SOUND bothers you, it can be
easily turned o by pressing and holding the HF ONLY buon.
Electromagnec waves from base staons, Wi/WiMax networks, or DECT phones, connected objects,
etc.
1. Press the ON/OFF buon briey to turn on the standard mode.
2. Press the “HF ONLY” buon to acvate the high-resoluon HF mode
3. Hold the detector with your arm slightly extended forward.
4. Move around slowly to detect electromagnec elds. The device performs a new detecon
every two seconds.
Note: In this mode, all 24 LEDs are used for wave detecon. The LEDs at the boom of the display indi-
cate the lowest radiaon level, while the LEDs at the top of the display show the highest level.
Levels :
LED :
G = green LED
Y= yellow LED
R = red LED
EF
in V/m :
HF
-in µW/m
-in V/m :
MF
in nT :
5
Hypersensitive mode table:
When the FULL HF funcon is acvated, the unit detects only high-frequencies.
Radiaon power is indicated by all 24 LEDs, from le to right from the boom to top, with a detecon
spectrum of 1 MHz to 10 GHz.
Standard Mode Table:
It indicates the power of radiaon by each row of 8 LEDs and 14 levels. The table indicates the numeri-
cal values for the LEDs :
• The magnec eld with a 3D detecon spectrum of 10 Hz to 5 kHz.
• The electric eld with a detecon spectrum of 10 Hz - 5 kHz.
• The high-frequency eld with a detecon spectrum of 1 MHz to 10 GHz.
Levels : 012345678910 11 12 13 14
LED :
G = green LED
Y= yellow LED
R = red LED
G1
G1
+
G2
G2
G2
+
Y1
Y1 Y1 +
Y2 Y2 Y2 +
Y3 Y3 Y3 +
R1 R1 R1 +
R2 R2 R2 +
R3 R3
EF
in V/m : 0612 17 22 26 30 34 39 45 52 60 70 80 90
HF
-in µW/m² :
-in V/m :
0
0
15
0,08
40
0,12
70
0,16
110
0,1
9
150
0,23
200
0,27
300
0,33
500
0,43
750
0,53
1000
0,61
1250
0,69
1500
0,75
1750
0,81
2000
0,86
MF
in nT : 020 60 100 140 180 220 300 400 650 1000 1500 2000 2500 3000
High-frequency
levels: 012345678910 11
in µW/m² :
in V/m :
0
0
1
0,02
2,5
0,03
10
0,06
20
0,09
40
0,12
50
0,14
75
0,17
100
0,19
140
0,22
180
0,25
225
0,29
levels : 12 13 14 15 16 17 18 19 20 21 22 23
in µW/m²
in V/m :
300
0,33
400
0,38
550
0,45
750
0,53
1000
0,61
1250
0,69
1500
0,75
1750
0,81
2000
0,86
2250
0,92
2500
0,96
2750
1