Ericsson Base Station F800 Guida rapida

COPYRIGHT 1996 Ericsson Mobile Communications AB
EN/LZB 115 681 R1
Base Station F800
Field Service Manual

RUBRIKFÖRTECKNING
LIST OF HEADINGS
Document maintenance 1
Dokumentnr - Document No
EN/LZB 115 681
Safety instructions
Datum -Date
96-06-06
Rev
A 2
FIELD SERVICE MANUAL
F800
Overview
3
Technical specifications
4
Installation
5
Operations instructions
6
Spare parts list
7
Service tools
8
Service information
9
This manual is provided by Ericsson Mobile
Communications without any kind of warranty.
Improvements and changes in this manual due to
typographical errors, inaccuracies in current information, or
improvements to programs and/or equipment may be
made by Ericsson Mobile Communications at any
Cabinet
10
time and without notice. These changes will, however, be
incorporated into new editions of this manual. Transceiver unit
11
All right reserved.
COPYRIGHT 1996
Ericsson Mobile Communications AB Applications
12


DOCUMENT LIST
1 (3)
Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.
KL/ESE Rune Tapper ECS/S/LT-96:1036
Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File
KI/ESE (Rune Tapper) 1999-05-25 D
F800 Field Service Manual
Document list
Chapt Document name Document number Rev
1. Document maintenance
Distribution list 031 51-LZB 115 681 B
Revision journal 109 21-LZB 115 681 A
Document list (this document) ECS/S/LT-96:1036 D
2. Safety instructions
Warning, health risk! ECS/S/LT-96:5031 A
Warning, health risk! ECS/S/LT-96:5032 A
Handling MOS devices ECS/S/LT-96:5033 A
Warning, high voltage! ECS/S/LT-96:5034 A
Information about ESD LZT 109 170 Ue -
3. Overview
Product structure 1315-KRD 103 10 Ux B
Mechanical structure ECS/S/LT-96:5035 A
Manufacturing instruction 1510-KRD 103 10 ux A
Coding scheme 1518-KRD 102 01 usv C
4. Technical specifications
Ericsson F800 Technical data EN/LZT 123 593 R3
F800 Product sheet EN/LZT 123 841 A
5. Installation
Installation ECS/S/LT-96:5036 A
Installation instruction 1531-SXK 107 2274/1 UX B
Installation instruction 1531-SXK 107 2274/4 UX A
Lightning protection for masts ECS/S/LT-96:5037 A
F800 Commissioning ECS/S/LT-96:1042 A
6. Operating Instructions
Operating Instructions F800 ECSTAP 97:1055 A

DOCUMENT LIST
2 (3)
Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.
KL/ESE Rune Tapper ECS/S/LT-96:1036
Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File
KI/ESE (Rune Tapper) 1999-05-25 D
7. Spare parts list
Spare parts list ECS/S/LT-96:5042 A
8. Service tools
LPC 102 213 F800 Test Handset KTR97:2444 A
Fault tracing F800 KTR97:2486 A
Special service tools for F800 15/EN/LZB 115 681 R1 Uen A
Service unit F800 15188-LPC 102 81 UX A
F800 personality programming ECS/S/LT:96-1014 A
9. Service information
Service information SI95-011 A
Service information SI96-003 A
Service information SI96-004 A
10. Cabinet
F800 Radio base station concept 109 21-KRD 103 10 - 1 Uen A
Cable 151 88-RPM 113 669 Ux B
Cable 151 88-RPM 113 671 Ux A
Cable 151 88-RPM 113 670 Ux A
Cable terminal info F800 193 12-SXK 107 2274/4 Uen A
Cable terminal info F800 193 12-SXK 107 2274/4 Uen B
Connection cable 151 88-RPM 113 1511 Ux A
Connection cable 151 88-RPM 113 1511 Ux B
Connection cable 151 88-RPM 113 1512 Ux A
Connection cable 151 88-RPM 113 1512 Ux B
Connection cable 151 88-RPM 113 1513Ux A
Fan kit 151 88-BKV 301 203 Ux A
Connection cable 151 88-RPM 113 1703 Ux A
Wiring diagram F800 MRS3000 107 31-SXK 107 2274/1 Ux E
Wiring diagram F800 MRS5000 107 31-SXK 107 2274/2 Ux D
Circuit board 1911-ROA 117 2010 Ux A
Printed board 1078-ROA 117 2010 Ux A
Station unit C700 151 88-NTM 201 57 Ux E
Assembly drawing F800 151 88-SXK 107 2274/1 Ux C
Wiring diagram transceiver unit F800 107 31-KRD 103 10 Ux A
Assembly drawing F800 151 88-SXK 107 2274/4 Ux C
11. Transceiver unit
Logic unit 3/EN/LZB 115 681 R1 Uen A
F800 Circuit description ECS/S/LT-96:5044 A
Logic board F800, circuit diagram 1911-ROA 119 8736 UEN C
Logic board F800, mounting drawing 1078-ROA 119 8736 Ux B

DOCUMENT LIST
3 (3)
Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.
KL/ESE Rune Tapper ECS/S/LT-96:1036
Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File
KI/ESE (Rune Tapper) 1999-05-25 D
12. Applications
F800 as radio link S/XT 95:7049 A
F800 as repeater station ECS/S/LT-96:1013 A
F800 as OEM station ECS/S/LT-96:1018 A
Enclosure
F800 Personality Programming Tool EN/LZY 213 633 1.47

Öppen Open
INFORMATION
1 (1)
Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.
KL/ESE Magnus Lindahl ESE-9902150
Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File
KL/ESE (Rune Tapper) 1999-10-27 A
This manual is an
unregistered copy
and will not be
updated!
This manual is provided by Ericsson Sverige AB without any kind of
warranty. Improvements and changes in this manual due to typographical
errors, inaccuracies in current information, or improvements to programs
and/or equipment may be made by Ericsson Sverige AB at any time and
without notice. These changes will, however, be incorporated into new
editions of this manual.
COPYRIGHT1999 Ericsson Sverige AB
All rights reserved.

SAFETY PRECAUTIONS
1 (4)
Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.
KL/ECS/S/LT Magnus Lindahl ECS/S/LT-96:5031
Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File
KI/ECS/S/LTC (Ulf Brömster) 1996-06-03 A
965031.doc
WARNING, HEALTH RISK!
Beryllium oxide
The transistors in the power amplifier’s driver stage and in the power amplifier contain
beryllium oxide ceramics (BeO). Dust particles of this substance may be dangerous to
your health if you inhale or get them on your skin.
Therefore, DO NOT IN ANY WAY INTERFERE WITH THE TRANSISTORS. It is, vital
that you comply with the directions given in the appended “Beryllia safety precautions”.
BERYLLIA SAFETY PRECAUTIONS
Introduction
This appendix details the safety precautions when handling components containing
Beryllium oxide. Dust from this material can present a health hazard unless adequate
precautions are taken.
The hazard
The material is highly dangerous in a dust form when it might be inhaled or enter a cut
or skin irritation area.
If dust is caused as a result of chafing, filing or breakage and is inhaled, a single
exposure lasting minutes or seconds can cause injury to skin or mucous membranes
severe enough to endanger life or cause permanent injury. Particles penetrating the
skin through wounds or abrasions are liable to cause chronic ulceration’s.
Symptoms of poisoning indicated by respiratory troubles or cyanosis (grey blue
discoloration of the skin), may develop within a week, or after a period extending to
several years.

SAFETY PRECAUTIONS
2 (4)
Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.
KL/ECS/S/LT Magnus Lindahl ECS/S/LT-96:5031
Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File
KI/ECS/S/LTC (Ulf Brömster) 1996-06-03 A
965031.doc
COMPONENTS
Power transistors, diodes and thyristors
Power transistors, diodes and thyristors, as received in the manufacturers packing, are
clearly identified by attached information. They should be stored in the original packing
and not mixed with other items. The Beryllia is encapsulated and components are safe
to handle for replacement purposes. Care should be exercised in removing defective
items to ensure that they do not become physically damaged.
They MUST NOT:
be carried loosely in a pocket, bag or container with other components where they
may rub together or break and disintegrate into dust
be heated excessively (normal soldering is quite safe)
be broken open for inspection or in any way abrased by tools.
Heat sink washers
Some of the heat sink washers contain Beryllia. When new these are packed
individually.
They MUST NOT:
be stored loosely
be filed, drilled or any way tooled
heated other than when clamped in heat sink application.
They are best handled with gloves or cloth when being removed from equipment.
Cathode ray tubes and ceramic applications
Some products of cathode ray tube are coated on the inside with a ceramic beryllium
oxide mixture. The tube is safe unless the glass is broken but should this occur.
DO NOT:
handle the broken glass with bare fingers
blow on the exposed surface (because of the danger of inhalation).
Ceramic cylinders or formers, identified by blue coloration or black lines, are safe to
handle provided they are not damaged. In the latter event take precautions as with
other components.

SAFETY PRECAUTIONS
3 (4)
Uppgjord (även faktaansvarig om annan) - Prepared (also subject responsible if other) Nr - No.
KL/ECS/S/LT Magnus Lindahl ECS/S/LT-96:5031
Dokansv/Godk - Doc respons/Approved Kontr - Checked Datum - Date Rev File
KI/ECS/S/LTC (Ulf Brömster) 1996-06-03 A
965031.doc
Disposal
Defective and broken components MUST NOT be disposed of in containers used for
general refuse.
Defective components should be individually wrapped, clearly identified as
“DEFECTIVE BERYLLIA COMPONENTS” and returned for subsequent disposal. Such
components securely packed and with inside identification, may also be returned
directly to the manufacturer.
Broken components should be individually wrapped and identified as “BROKEN
BERYLLIA COMPONENTS”. They MUST NOT be sent through the post and should
be returned to a depot by hand.
Medical precautions
If Beryllia is believed to be on, or have entered the skin through cuts or abrasions, the
area should be thoroughly washed and treated by normal first aid methods followed by
subsequent medical inspection.
Suspected inhalation should be treated as soon as possible by a doctor, preferably at
a hospital.
Indice
Altri manuali Ericsson Accessori

Ericsson
Ericsson RBS 2206 Specifiche tecniche

Ericsson
Ericsson RBS 6401 Manuale utente

Ericsson
Ericsson RBS 2409 Manuale utente

Ericsson
Ericsson CME 20 R6.1 Manuale utente

Ericsson
Ericsson RBS 6501 Manuale utente

Ericsson
Ericsson RBS 2308 Specifiche tecniche

Ericsson
Ericsson RBS 2401 Manuale utente

Ericsson
Ericsson RBS 6302 Manuale utente

Ericsson
Ericsson RBS 2106 Manuale utente

Ericsson
Ericsson RBS 6501 Manuale utente