South Bend, Indiana USA | networketi.com ADH INSTRUCTION MANUAL | PART NO.24100 REV B
5
5. Note how the five electrical leads are
connected to the existing Power Filter
Module, then use a needle nose pliers
to carefully disconnect the leads from
the module. The two leads on the
Load side connect to the green power
connector. The three leads on the
Line side connect to the power supply.
Of the two connector leads, the black
lead is the line and the white lead is
neutral. Of the three output leads, the
black lead is the line, the white lead is
neutral, and the green/yellow lead is
ground. All of these leads will connect
to the new module the same way.
Figure 2. THE POWER FILTER MODULE.
The two leads on the
Load side connect to
the green power
connector.
The three leads on the
Line side connect to
the power supply.
6. Using the nut driver, remove and
retain the nuts and lock washers
securing the existing module to the
chassis. Once all five electrical leads
have been disconnected and the
mounting hardware has been
removed, remove the existing Power
Filter Module from the unit.
7. Position the new Power Filter Module
over the Pem
®
studs on which the
original module was installed. Using
the nuts and lock washers retained in
step 6, install the new Power Filter
Module and torque to 10 in/lb.
Connect the electrical leads in the
corresponding locations on the new
Power Filter Module from which they
were removed on the old module.
Refer to the following tables. Make
sure all leads are secure.
8.
Load Side Connections
Black Line
NeWhite
Line Side Connections
Black Line
White Ne
Green/Yellow
12. Reinstall the front cover removed in
step 4. If it was placed upside down
on the lid of the unit during this
procedure, carefully turn the cover
back over and work it back into
position, past the wires and other
components in the enclosure.
Reinstall the four corner screws
securing the front cover to the
chassis.
13. Reconnect the ground wire by
inserting it behind the retaining
screw from which it was removed,
then tighten the ground wire
retaining screw. Reconnect the green
power connector by holding it in
place then tightening the two captive
screws removed in step 3. Reconnect
both ends of the orange ethernet
cable removed in step 3. It does not
matter which end of the ethernet
cable goes into which receptacle.