2
Table of Contents
Table of Contents ...................................2
Safety Information ..................................2
Warranty ..........................................2
Pre-Installation.....................................3
Planning Installation ...............................3
Tools Required ....................................3
Package Contents .................................3
Hardware Included.................................3
Installation ........................................4
Mounting Options..................................4
Power Supply Options ..............................5
Linking Feature.....................................7
Beam Adjustment Feature ............................8
Light Distribution ...................................8
Care and Cleaning ..................................9
Troubleshooting ....................................9
Safety Information
CAUTION: To reduce the risk of fire, electric shock, or injury
to persons:
□Use only insulated staples or plastic ties to secure cords;
□Route and secure cords so that they will not be pinched or
damaged when the cabinet is pushed to the wall;
□Do not use for recessed installation in ceilings or soffits.
CAUTION: The National Electrical Code (NEC) does not
permit cords to be concealed where damage to insulation
may go unnoticed. To prevent fire danger, do not run cord
behind walls, ceilings, soffits, or cabinets where it may
be inaccessible for examination. Cords should be visually
examined periodically and immediately replaced when any
damage is noted.
CAUTION: Maximum number of units to be interconnected:
53505111 (32 in. under cabinet light): maximum 18 units
53506111 (42 in. under cabinet light): maximum 14 units
Maximum distance between connected units is 14.5 in.
CAUTION: To prevent electric shock, match wide blade of
the plug to the wide slot and fully insert into the electrical
outlet.
NOTICE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
□Reorient or relocate the receiving antenna.
□Increase the separation between the equipment and the receiver.
□Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
□Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications not expressly approved
by the party responsible for compliance could void the user’s
authority to operate the equipment.
Warranty
This product is warranted for a period of 5 years from the date of original purchase against defects in materials and workmanship. If this
product should fail to operate due to defects in material or workmanship within 60 months of purchase, see www.ETiSSL.com for details.
This product will be repaired or replaced, at ETi’s option. This warranty is expressly limited to repair or replacement of product, and liability
for direct, incidental, or consequential damages is hereby expressly excluded. Some states do not allow exclusions of direct, incidental or
consequential damages, so the above limitation of exclusion may not apply to you. This warranty gives the consumer specifc legal rights,
which vary from state to state. WARRANTY IS VOID IF PRODUCT IS NOT USED FOR THE PURPOSE WHICH THIS PRODUCT IS MANUFACTURED.

3 www.ETiSSL.com
Please contact 1-855-384-7754 for further assistance.
Pre-Installation
PRODUCT DESCRIPTION AND CHARACTERISTICS
An LED under cabinet light fixture can be directly mounted to the underside of a cabinet or wall and requires little space. It is energy-saving,
environmentally friendly, and used for emitting soft and even distribution of light.
PLANNING INSTALLATION
Before beginning assembly, installation or operation of product, make sure all parts are present. Compare parts with the package contents
list. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact customer service for replacement
parts.
NOTE: Keep your receipt and these instructions for proof of purchase.
If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do the installation.
Identify the desired location for the LED fixture to make sure the length of the fixture fits the cabinet.
TOOLS REqUIRED
Phillips
screwdriver Measuring Tape
Power Drill
with 1/8 in.
drill bit
PACKAGE CONTENTS
Part Description quantity
A Under Cabinet Light
Fixture
1
HARDWARE INCLUDED
NOTE: Hardware not shown to actual size.
Part Description quantity
AA Strain Relief 1
BB O-Ring 4
CC Wire Clip 2
DD Mounting Screw (long) 2
EE Drywall Anchor 4
FF Mounting Plate 1
GG 5 ft. Power Cord 1
HH 14.5 in. Linking Cable 1
II End-to-End Connector 1
JJ Mounting Screw (short) 4
AA
A
BB CC DD
EE
FF
II
GG HH
JJ

4
1 Installing using the MagnaMount™ mounting plate
□Position the mounting plate (FF) against the underside of the cabinet where you want the fixture to be mounted and mark the
locations of the three screw holes (Model# 53505111) or 4 screw holes (Model# 53506111) with a pencil. Take the mounting
plate (FF) down away from the cabinet once the location has been marked.
□Place a short mounting screw (JJ) into the hole on one end of the mounting plate (FF) and attach an O-ring (BB) to the end of
the mounting screw (JJ) to hold it in place. Repeat with the remaining mounting screws (JJ).
□If attaching to drywall instead of to the underside of a cabinet, drill pilot holes and tap in the drywall anchors (EE) at the screw
positions.
□Hold the mounting plate (FF) up to the cabinet, matching the screw positions to the locations marked on the underside of the
cabinet.
□Use a power tool to tighten the mounting screws (JJ).
□Position the under cabinet light fixture (A) on the MagnaMount™ mounting plate (FF) and adjust the alignment as needed.
NOTE: Only 3 of the 4 short mounting screws included are used to install the MagnaMount mounting plate for Model 53505111. All 4 of the
short mounting screws are used to install the MagnaMount mounting plate for Model 53506111.
WARNING: RISK OF ELECTRIC SHOCK. Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off
the circuit breaker before removing the existing light fixture or installing the new one.
If replacing a previous direct wire fixture, with power disconnected to the electrical box, remove the existing fixture. Make a sketch of how
the current fixture is wired (by wire color) or mark the wires with masking tape and a pencil so you will know how to properly reconnect the
wires to the new LED light fixture.
Mounting Options
This undercabinet light can be installed either by mounting directly to the underside of the wood cabinet with screws or by installing the
MagnaMount™ mounting plate and attaching the light to the magnetic plate.
Installation
EE
FF
BB
JJ
FF
A

5 www.ETiSSL.com
Please contact 1-855-384-7754 for further assistance.
2 Installing by mounting the
fixture directly
□Identify and mark the desired location for the
LED fixture.
□If attaching to drywall instead of to the
underside of a cabinet, drill pilot holes and tap
in drywall anchors (EE) at the screw positions.
□Place a long mounting screw (DD) into the
hole on one end of the LED under cabinet light
fixture (A) and attach an O-ring (BB) to the
end of the mounting screw to hold it in place.
Repeat with the second long mounting screw
(DD) on the other end of the under cabinet light
fixture (A).
□Hold the under cabinet light fixture (A) up to
the cabinet, matching the screw positions to
the locations marked on the underside of the
cabinet.
□Use a power tool to tighten the mounting screw
(DD) on each end of the under cabinet light
fixture (A).
Installation (continued)
3 Connecting the power cord
□Remove the end cap on the “power in” end of the
under cabinet light fixture (A).
□Connect the power cord (GG) to the installed light under
cabinet light fixture (A).
□Use wire clips (CC) to affix the power cord (GG) to the
underside of the cabinet, if desired.
Power Supply Options
A
ADD
BB
A
A
CC GG

6
Knock out Holes
4 Making direct wire power connections
□Remove the five screws on the back of the under cabinet light
fixture (A) and open the back plate of the fixture.
□Determine which knock out hole in the back plate of the under
cabinet light fixture (A) will be closest to the power supply wire
feed and use a screwdriver to remove the knock out.
□Insert the threaded end of the strain relief (AA) through the knock
out hole from the outside.
□Feed the flexible whip or NM cable of the power supply through
the strain relief (AA) in the back plate of the under cabinet light
fixture (A) and tighten the clamp until it is secure.
□Connect the hot and neutral (black and white) wires from the
power supply box to the same color wires from the electrical
box.
□Connect the green wire from the power supply box to the
grounding wire from the electrical box.
□Cover the wire connections using wire connectors (not included)
and electrical tape (not included).
□Tuck all wire connections into the wire compartment in the under
cabinet light fixture (A) and reattach the back plate of the under
cabinet light fixture with the five screws removed earlier.
WARNING: Do not plug in the power cord when the fixture is
direct wired to the power supply to avoid a dangerous situation.
WARNING: Plug in End Cap before connect power.
Installation (continued)
A
Wire connectors
A
Back Plate
AA
AA

7 www.ETiSSL.com
Please contact 1-855-384-7754 for further assistance.
Model No. Part No. Maximum Connected Units
53505111 UC-32-10-930-SV-D 18
53506111 UC-42-15-930-SV-D 14
5 Operating the light fixture
□Use the toggle switch on the light fixture to control the lights.
□If the under cabinet lights are installed on a dimming circuit, use
the dimmer switch to adjust the brightness.
NOTE: Color of light warms from 3000K to 2200K when dimmed.
Installation (continued)
Toggle Switch
WARNING: RISK OF ELECTRIC SHOCK. Disconnect power to the under cabinet light before linking additional under cabinet lights.
□Multiple light fixtures can be connected,
up to a maximum of 300 total watts.
Only the first light fixture needs to be
plugged into an electrical outlet or
directly wired.
□Provide power to the fixtures only after
all linking connections have been made.
□Connect each additional fixture using either the
linking cable (HH) or end-to-end connector (II).
Remove the end cover and insert either the end-
to-end connector (II) or linking cable (HH) into
the receptacle in the end of each under cabinet
light fixture (A). When using the linking cable
(HH), the maximum distance between two light
fixtures is 14.5 in. using the linking cable (HH)
provided.
□Use wire clips (CC) to affix the linking cable (HH)
to the underside of the cabinet, if desired.
A A
A A
II
HH
Linking Feature

8
53505111 53506111
-90
-120
-150
-/+180
150
120
90
60
30
-60
-30
0
C0/180,100.6
C30/210,115.7
C60/240,125.6
C90/270,130.6
UNIT:cd
0
110
220
330
440
550
AVERAGE BEAM ANGLE(50%):120.6 DEG
53505111 53506111
-90
-120
-150
-/+180
150
120
90
60
30
-60
-30
0
C0/180,108.8
C30/210,113.1
C60/240,124.3
C90/270,127.5
UNIT:cd
0
80
160
240
320
400
AVERAGE BEAM ANGLE(50%):118.4 DEG
Beam Adjustment Feature
□Adjust the light angle to the area of the surface below
where light is desired by rotating the tabs on each end of
the under cabinet light fixture (A) to the desired position.
NOTE: A minimum of 60% of the total lumen output is achieved
in an adjustable beam angle of 22.5°.
Light Distribution

9 www.ETiSSL.com
Please contact 1-855-384-7754 for further assistance.
Care and Cleaning
CAUTION: Before attempting to clean the fixture, disconnect the power to the fixture by turning the breaker off or removing the fuse from the
fuse box.
□Clean the fixture with a soft, dry cloth.
□Do not use cleaners with chemicals, solvents, or harsh abrasives.
□Do not use liquid cleaner on the LEDs, LED driver, or wiring inside the light fixture.
Troubleshooting
WARNING: Before doing any work on the fixture, disconnect power to the light fixture.
Minor problems often can be fixed without the help of an electrician.
Problem Possible Cause Solution
The fixture will not light. The power is off. Ensure the power supply is on.
The circuit breaker is off. Ensure the circuit breaker is in the on position.
There is a bad connection. Check to ensure proper wire connections are made.
Contact a qualified electrician.
There is a defective switch. Contact a qualified electrician.
The fuse blows or the circuit breaker
trips when the light is turned on.
The wires are crossed or the power
wire is grounding out.
Check the wire connections.
Contact a qualified electrician or call ETiSSL
customer service 1-855-348-7754.
The light fixture flickers or makes a
buzzing sound.
The dimmer circuit is not compatible
with the product.
The dimming circuit is set outside the
dimming range of the product.
Check the product page at www.ETiSSL.com for a
list of compatible dimmers.
Turn or slide the dimmer switch to adjust the light
output until the flickering or buzzing stops.

Questions, problems, missing parts?
Call ETi SSL Customer Service
9 a.m. – 5 p.m., EST, Monday - Friday
1-855-ETI-SSLI (1-855-384-7754)
WWW.ETiSSL.COM
Retain this manual for future use.
Questo manuale è adatto per i seguenti modelli
1
Indice
Lingue:
Altri manuali ETI Apparecchio di illuminazione
Manuali Apparecchio di illuminazione popolari di altre marche

Emos
Emos CLASSIC ZY1431T Manuale utente

Westinghouse
Westinghouse Outdoor Lighting Fixture Manuale utente

Hedler
Hedler C 12 silent Manuale utente

Blizzard Lighting
Blizzard Lighting Puck: CSI Manuale utente

Energetic Lighting
Energetic Lighting ELYSL-5004 Series Manuale utente

Lightmaxx
Lightmaxx Shaft 5R Manuale utente

Cooper Lighting
Cooper Lighting Halo L3232E Manuale utente

Stageline
Stageline ODW-2410RGBW Manuale utente

Light Sky
Light Sky Tornado Series Manuale utente

Lightolier
Lightolier Paralyte 2424 PLA2G9LS26U Manuale utente

Lightolier
Lightolier Lytespan 83ED17S Manuale utente

Lightolier
Lightolier Calculite CS8226 Manuale utente