EUROSTER 1100W – USER MANUAL 3
•setting the temperature for the heating water circulating pump: press the right-
hand switch under the display – the figures will start blinking and the current
DHW temperature setpoint will be displayed
•use the right-hand and left-hand switches to increase/ decrease the displayed
temperature setpoint, as appropriate
•after ca. 4 sec. the display will stop blinking - this indicates that the preset
temperature has been stored. The display will return to displaying the current
temperature, as measured by the sensor on the heating circuit.
d. blowing time adjustment
•press and hold the right-hand switch until the figure to the right starts blinking.
The blinking value from 0 to 9 defines the blowing time, as per the table below.
•use the right-hand and left-hand switches to e tend/ shorten the blowing time, as
appropriate
•after ca. 4 sec. the display will stop blinking - this indicates that the setpoint has
been stored. The display will return to displaying the current temperature, as
measured by the sensor on the heating circuit.
e. blowing interval adjustment
•press and hold the left-hand switch until the figure to the left starts blinking. The
blinking value from 0 to 9 defines the blowing interval, as per the table below.
•use the right-hand and left-hand switches to e tend/ shorten the blowing interval,
as appropriate,
•after ca. 4 sec. the display will stop blinking - this indicates that the setpoint has
been stored. The display will return to displaying the current temperature, as
measured by the sensor on the heating circuit.
cyclic blowing time
code 0 1 2 3 4 5 6 7 8 9
time off 5sec. 10sec. 15sec. 20sec. 30sec. 40sec. 60sec. 80sec. 100sec.
cyclic blowing interval
code 0 1 2 3 4 5 6 7 8 9
time 20sec. 1min. 2min. 4min. 6min. 8min. 10min. 12min. 14min. 16min.
f. fan speed adjustment
•simultaneously press the two switches under the display until double zero “00”
symbol appears on the display (initially set to ma imum speed). Use the toggle
switches to change the code. During setting codes from 00 to 09 will appear on
the display, which correspond to the blower speed settings for the operating
status (blower is on). The flow rate is set with parameter, where 00 is the
MAXIMUM and 01 is the MINIMUM fan speed.
•use the right-hand and left-hand switches to set the desired fan speed,
•after ca. 4 sec. the display will stop blinking - this indicates that the setpoint has
been stored. The display will return to displaying the current temperature, as
measured by the sensor on the heating circuit.
g. automatic operation mode
•set the right hand switch () to 0
•circulating pump - the controller will switch on the pump when the temperature
measured on the sensor has e ceeded the setpoint by 2°C and switch it off when
the temperature has dropped by 3°C below the setpoint
•combustion blower – the controller features “initial burning” function activated
with the power switch. Upon each switching on the controller will check the
temperature of water in the boiler. If within an hour the temperature has not risen
above 30C the controller will switch off the blower (flame e tinction). If the
boiler temperature has risen up to the setpoint for the blower the “initial burning”
mode will be switched off and the user defined settings will be applied.