Eurotech Arcom VULCAN Manuale utente

VULCAN
Industrial Compact
Enclosure (ICE)
Technical Manual

VULCAN ICE
Arcom operates a company-wide
quality management system, which
has been certified by the British
Standards Institution (BSI) as
compliant with ISO9001:2000
Definitions
Arcom is the trading name for Arcom Control Systems Inc and Arcom Control Systems Ltd.
This product was known as the MERCURY until 30th June 2005. The internal (numeric) product codes used to identify this
product and its variants have not changed. Please contact our sales team if you have any questions (see page 18).
Disclaimer
The information in this manual has been carefully checked and is believed to be accurate. Arcom assumes no responsibility for
any infringements of patents or other rights of third parties, which may result from its use.
Arcom assumes no responsibility for any inaccuracies that may be contained in this document. Arcom makes no commitment to
update or keep current the information contained in this manual.
Arcom reserves the right to make improvements to this document and /or product at any time and without notice.
Warranty
This product is supplied with a 3 year limited warranty. The product warranty covers failure of any Arcom manufactured product
caused by manufacturing defects. The warranty on all third party manufactured products utilized by Arcom is limited to 1 year.
Arcom will make all reasonable effort to repair the product or replace it with an identical variant. Arcom reserves the right to
replace the returned product with an alternative variant or an equivalent fit, form and functional product. Delivery charges will
apply to all returned products. Please check www.arcom.com/support for information about Product Return Forms.
Trademarks
ARM and StrongARM are registered trademarks of ARM Ltd.
Intel and XScale are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other
countries.
Windows CE .NET is a trademark of the Microsoft Corporation.
CompactFlash is the registered trademark of SanDisk Corp.
Linux is a registered trademark of Linus Torvalds.
RedBoot and Red HatTM are registered trademarks of Red Hat Inc.
VxWorks is a registered trademark of Wind River.
Bluetooth is a registered trademark of Bluetooth SIG, Inc.
All other trademarks recognized.
Revision History
Manual PCB Date Comments
Issue A 11th June 2004 First full release of manual.
Issue B 6th September 2004 ICE and COMMs cable modifications.
Issue C 16th May 2005 Updated to reflect product name change.
© 2006 Arcom.
Arcom is a subsidiary of Eurotech Group.
www.eurotech.com
For contact details, see page 18.

VULCAN ICE Contents
Contents
Introduction ........................................................................................................................................4
VULCAN ICE ‘at a glance’ .....................................................................................................5
Handling your board safely ....................................................................................................6
About this manual ..............................................................................................................................7
Related documents ................................................................................................................7
Conventions ...........................................................................................................................7
Overview of the VULCAN ICE ports ..................................................................................................8
Connector details ...............................................................................................................................9
Communication ports .............................................................................................................9
USB 2.0 ports.......................................................................................................................11
Ethernet (10/100Base-T) ports ............................................................................................12
Digital I/O port ......................................................................................................................13
Additional I/O break out .......................................................................................................14
Mounting details...............................................................................................................................15
Front panel dimensions........................................................................................................15
Back panel dimensions ........................................................................................................16
Left hand side panel dimensions .........................................................................................16
Right hand side panel dimensions .......................................................................................17
Appendix A – Contacting Arcom.......................................................................................................18
Appendix B – Specification ..............................................................................................................19
Index ................................................................................................................................................20

VULCAN ICE Introduction
Introduction
The VULCAN ICE provides a comprehensive enclosure solution for Arcom’s VULCAN
single board computer. The enclosure can be configured to suit a complete range of
embedded applications with options.
The VULCAN ICE is fully CE compliant and is intended for use with all variants of the
VULCAN board.
The enclosure contains a VULCAN single board computer with suitable break outs.
It includes the following:
Power input for +5V DC input.•
•
•
•
•
•
•
•
•
3 RS232 serial ports (D type 9-way plugs).
1 RS422/485 serial port (D type 9-way plug).
1 digital I/O port (D type 25-way socket).
2 RJ45 Ethernet ports (10/100Base-T).
2 USB 2.0 type A ports.
Reset button.
CF+ socket break out.
Expansion space for a PC/104 card with 2 additional I/O break outs.
This product was known as the MERCURY until 30th June 2005. The internal
(numeric) product codes used to identify this product and its variants have not
changed. Please contact our sales team if you have any questions (see
page 18).
© 2005 Arcom Issue C 4

VULCAN ICE Introduction
Handling your board safely
Anti-static handling
The VULCAN fitted inside the VULCAN ICE contains CMOS devices. These could be
damaged in the event of static electricity being discharged through them. At all times,
please observe anti-static precautions when handling circuit boards. This includes
storing boards in appropriate anti-static packaging and wearing a wrist strap when
handling.
Packaging
Should a board need to be returned to Arcom, please ensure that it is adequately
packed, preferably in the original packing material.
© 2005 Arcom Issue C 6

VULCAN ICE About this manual
About this manual
This manual describes the Industrial Compact Enclosure (ICE) and related
interconnections.
Related documents
The VULCAN ICE Technical Manual is normally supplied as part of the VULCAN
Development Kit, which also includes the VULCAN Technical Manual and the Arcom
Embedded Linux Quickstart Manual. Other manuals are referred to from time to time.
These are provided on the CD-ROM that accompanies your Development Kit.
Conventions
Symbols
The following symbols are used in this guide:
Symbol
Explanation
Note - information that requires your attention.
Tip - a handy hint that may provide a useful
alternative or save time.
Caution – proceeding with a course of action may
damage your equipment or result in loss of data.
Jumper fitted on pin A.
Jumper fitted on pin B.
Jumper is fitted.
Jumper is not fitted.
B
A
B
A
© 2005 Arcom Issue C 7

VULCAN ICE Overview of the VULCAN ICE ports
Overview of the VULCAN ICE ports
The VULCAN ICE has a number of ports. These are described below:
Power input jack The VULCAN enclosure requires a 5V supply. This is connected
via a 2.1mm jack. The typical current consumption is 700mA
(VULCAN board only).
Ethernet Two RJ45 Ethernet ports (10/100Base-T):
‘LINK/ACT’ yellow LED flashes when there is Ethernet traffic.•
• ‘100’ green LED comes on when a 100Base-T connection is
made.
USB 2.0 2 A type USB2.0 ports.
COM1 9-way D type break out for COM1 (RS232).
COM2 9-way D type break out for COM2 (RS232).
COM3 9-way D type break out for COM3 (RS232).
COM4 9-way D type break out for COM4 (RS485/RS422).
Digital I/O 25-way D type break out for TTL digital I/O.
CF+ Break out for CF+ socket.
Spare I/O It is possible to fit one PC/104 module in the VULCAN enclosure.
Two spare locations are included to allow the module to be
broken out. These locations are fitted with blanking plates as
standard.
© 2005 Arcom Issue C 8

VULCAN ICE Connector details
Connector details
This section describes the connectors that are included with the VULCAN ICE.
Communication ports
The following tables show the generic conversion from the 40-way box header
connector on the VULCAN to the four 9-way D connectors that appear on the outside of
the ICE.
Communication port 1 (RS232)
J7 - VULCAN
40-way box header
Signal name 9-way
D type plug
N/C 1
33 Receive data (RX) 2
35 Transmit data (TX) 3
N/C 4
39 Ground 5
N/C 6
34 Request To Send (RTS) 7
36 Clear To Send (CTS) 8
N/C 9
Communication port 2 (RS232)
J7 - VULCAN
40-way box header
Signal name 9-way
D type plug
N/C 1
13 Receive data (RX) 2
15 Transmit data (TX) 3
N/C 4
17 Ground 5
N/C 6
14 Request To Send (RTS) 7
16 Clear To Send (CTS) 8
N/C 9
© 2005 Arcom Issue C 9

VULCAN ICE Connector details
Communication port 3 (RS232)
J7 - VULCAN
40-way box header
Signal name 9-way
D type plug
21 Data Carrier Detect (DCD) 1
23 Receive data (RX) 2
25 Transmit data (TX) 3
27 Data Terminal Ready (DTR) 4
29 Ground 5
22 Data Set Ready (DSR) 6
24 Request To Send (RTS) 7
26 Clear To Send (CTS) 8
28 Ring Indicator (RI) 9
Communication port 4 (RS485/RS422)
J7 - VULCAN
40-way box header
Signal name 9-way
D type plug
N/C 1
N/C 2
5 RX/TX+ 3
7 RX+ 4
9 Ground 5
N/C 6
6 RX/TX- 7
8 RX- 8
N/C 9
© 2005 Arcom Issue C 10
Altri manuali per Arcom VULCAN
1
Indice
Altri manuali Eurotech Allegato