evoheat EVO FLOW GS 10 Guida


Contents
1. Safey precautions 1
2. Specification 2
3. Installation and Connection 5
4. Usage and Operation 10
5. Maintenance 16
6. Excursus 18
7.
Appendix
20

ELECTRICAL POWER MUST BE SWITCHED OFF
BEFORE STARTING ANY WORK ON JUNCTION BOXES
The aim of this manual is to provide instructions for installation, commissioning, operation.
WARNING !
The installation, commissioning and
maintenance of these machines should be
performed by qualified personnel having a
good knowledge of standards and local
regulations, as well as experience of this
type of equipment.
WARNING !
Any wiring produced on site must comply
with local electrical regulations.
WARNING !
Ensure that the electrical supply
corresponds to the specification indicated
on the unit's maker's plate before
proceeding with the connection in
accordance with the wiring diagram
supplied.
WARNING !
The unit must be EARTHED to avoid any
risks caused by insulation defects.
WARNING !
No wiring must come in contact with the
heat source or the fan rotating parts.
WARNING !
Preparation for shutting down the unit for a
prolonged period if the installation does
not contain glycol, the evaporator and the
chilled water pipes need to be carefully and
completely drained of water.
Take care !
The unit should be handled using lifting and
handling equipment appropriate to the unit's
size and weight.
Take care !
It is forbidden to start any work on the
electrical components without switching off
the electrical supply to the unit.
Take care !
It is forbidden to start any work on the
electrical components if water or high
humidity is present on the installation site.
Take care !
When the unit is being connected, ensure that
no impurities are introduced into the pipe
work and the water circuits.
Take care !
A mesh filter must be provided on the
hydraulic pump and in exchanger water inlets.
The Manufacturer's warranty will not apply if the installation
recommendations listed in this manual are not followed.
1-Safety precautions
1

2-Specification
2.1 Performance data of the Unit
Super Heating Capacity is the standard parameter. The hot water capacity of super heating is the
capacity in an hour in cooling in standard condition.(the water temperature is heated from 20℃to 50℃)
Heating:Using Side Water Temp.(In/Out):30℃/35℃;Heat Source Water Temp.(In/Out):10℃/-;
Cooling:Using Side Water Temp.(In/Out):12℃/7℃;Heat Source Water Temp.(In/Out):25℃/30℃.
Model
Heating Capacity
Cooling Capacity
Heating Power Input
Cooling Power Input
Heating Running Current
Cooling Running Current
Super Heater Capacity
Pump of super heater power input
water head
Power Supply
Compressor
Type
Number
Type
Water Flow Volume
Water Pressure Drop
Water Connection(In/Out)
pump
water head
Type
Water Flow Volume
Water Pressure Drop
Water Connection(In/Out)
Pump
water head
Noise
Unit Net Dimensions(L/W/H)
Unit Shipping Dimensions(L/W/H)
Net Weight
Shipping Weight
Heat source
Using side
GS
kW
BTU/h
kW
BTU/h
kW
kW
A
A
kW
kW
m
3
m/h
kPa
Inch
kW
m
3
m/h
kPa
Inch
kW
m
dB(A)
mm
mm
kg
kg
14
14.5
50000
11.0
38000
2.8
2.8
12.3
12.2
1.6
0.1
5.0
230V~/50Hz
Scroll
1
Plate
2.8
13
1
0.2
6
Plate
2.1
18
1
0.1
4.5
40
17
17.8
60700
13.0
44000
3.4
3.3
14.8
14.3
1.8
0.1
5.0
230V~/50Hz
Scroll
1
Plate
3.3
14.5
1
0.2
5
Plate
2.4
21
1
0.2
6
42
14-3
14.5
50000
11.0
38000
2.8
2.8
5.0
5.0
1.6
0.1
5.0
380V/3N~/50Hz
Scroll
1
Plate
2.8
13
1
0.2
6
Plate
2.1
18
1
0.1
4.5
40
see the drawing of the units
see package label
see nameplate
see package label
10
10.0
34000
8.5
29000
2.0
2.2
8.5
9.3
1.2
0.1
5.0
230V~/50Hz
Rotary
1
Plate
2.1
13
1
0.2
6
Plate
1.5
11
1
0.1
4.5
38
2

Super Heating Outlet
Super Heating Intlet
2-Specification
2.1 Performance data of the Unit
Super Heating Capacity is the standard parameter. The hot water capacity of super heating is the
capacity in an hour in cooling in standard condition.(the water temperature is heated from 20℃ to 50℃)
Heating:Using Side Water Temp.(In/Out):30℃/35℃;Heat Source Water Temp.(In/Out):10℃/-;
Cooling:Using Side Water Temp.(In/Out):12℃/7℃;Heat Source Water Temp.(In/Out):25℃/30℃.
Model
Heating Capacity
Cooling Capacity
Heating Power Input
Cooling Power Input
Heating Running Current
Cooling Running Current
Super Heater Capacity
Pump of super heater power input
water head
Power Supply
Compressor
Type
Number
Type
Water Flow Volume
Water Pressure Drop
Water Connection(In/Out)
pump
water head
Type
Water Flow Volume
Water Pressure Drop
Water Connection(In/Out)
Pump
water head
Noise
Unit Net Dimensions(L/W/H)
Unit Shipping Dimensions(L/W/H)
Net Weight
Shipping Weight
Heat source
Using side
GS
kW
BTU/h
kW
BTU/h
kW
kW
A
A
kW
kW
m
3
m/h
kPa
Inch
kW
m
3
m/h
kPa
Inch
kW
m
dB(A)
mm
mm
kg
kg
see the drawing of the units
see package label
see nameplate
see package label
3
22
22.0
75000
17.0
60000
4.3
4.3
7.6
7.7
2.3
0.1
5.0
380V/3N~/50Hz
Scroll
1
Plate
4.1
16
1
0.2
5
Plate
3.1
27
1
0.2
6
44
19
19.3
65800
15.0
52000
3.7
3.8
6.6
6.8
2.1
0.1
5.0
380V/3N~/50Hz
Scroll
1
Plate
3.7
16
1
0.2
5
Plate
2.7
25
1
0.2
6
42
17-3
17.8
60700
13.0
44000
3.4
3.3
6.1
5.9
1.8
0.1
5.0
380V/3N~/50Hz
Scroll
1
Plate
3.3
14.5
1
0.2
5
Plate
2.4
21
1
0.2
6
42

2.2 The dimensions for the Unit
2-Specification
4
GS10 to GS17
600
Super Heating Outlet
Super Heating Intlet
Wire access

5
3.1 Installation:
Heat pump & Fan coil & Hot water
Tap water
Using water
Water tank
60 ℃ inside
Fan coil
Water pump Valve
Heat pump & Fan coil & Hot water& floor heating
3-Installnation and connection
Using water
Water tank
60 ℃ inside
Fan coil
Water pump Valve
Tap water

6
Water temp control
Heat pump & ceiling heating &constant-humidifyer & hot water
Heat pump & Fan coil & hot water (parallel connection)
Fan coil Water pump Valve
3-Installnation and connection
Fan coil
Water pump Valve
Tap water
Using water
Water tank
60 ℃ inside

7
3-Installnation and connection
Heat collect system base on the existent air-conditioning system
Existent air-conditioning system
Main unit
of the
existent
AC
Using water
Fan coil
Water pump
Valve
Installation items:
The factory only provides the main unit ; the other items in the illustration
are necessary spare parts for the water system ,that provided by users or the installer.
Attention:
Please follow these steps when using for the first time
1.Open valve and charge water.
2.Make sure that the pump and the water-in pipe have been filled with water.
3.Close the valve and start the unit.
Water tank
60 ℃ inside

8
3-Installnation and connection
Tap water
Using water
Water tank
60 ℃ inside
Water temp control
Fan coil
Water pump
Valve
Heat pump & ceiling heating &constant-humidifyer & hot water
Water tank
Floor Coil
Outside Ground
Water Layer
Effective
Depth
Heat pump & ceiling heating &constant-humidifyer & hot water
Questo manuale è adatto per i seguenti modelli