Evolution Aqua Varipump 10000 Manuale utente

INSTRUCTION MANUAL
Evolution Aqua Ltd. - Evolution House - Kellet Close - Wigan - Lancashire - United Kingdom - WN5 0LP
UK
English
VARIPUMP12811181MAN
PLEASE READ all of the instruction manual before attempting
to install or operate the Varipump

WARNING: PLEASE READ THE FOLLOWING
SAFETY INFORMATION FIRST.
IMPORTANT SAFETY INFORMATION
- Please read the instruction manual carefully.
- The electrical installation is to be done by a qualified electrician,
in accordance with applicable electrical codes.
- WARNING: Always shut off electrical power before installation and /
or servicing this pump.
- A residual current device (RCD), also known as the residual current
circuit breaker (RCCB), with a tripping current not exceeding 30mA
must be installed in the supply circuit.
- A means of disconnection from the supply having a contact separation
of at least 3mm in all poles must be incorporated in the wiring.
- Check the pumps name plate for the following:
Voltage, Amp draw and Cycle.
- Carefully, examine the power cord before use.
- Do not use this power cord if there is any visible damage.
- Do not use this power cord in water or if the motor or electrical
receptacle is in contact with any standing water.
- This power cord should only be plugged into a properly installed RCD.
- Always test cycle a RCD to determine its condition before use.
- Improper installation can create electrical hazards which could result
in property damage, serious injury or death. Improper installation will
void the warranty.
- Do not submerse the controller in water.
- The pump should be operated when permissible temperature is
between 0˚C and 35˚C. The pump should never be operated
outside of these temperatures or damage may occur.
- Young children must always be supervised near ponds.
Disposal Of Your Old Product
Your product is designed and manufactured with high quality material and components,
which can be recycled and reused. When this crossed-out wheeled bin symbol is attached
to a product, it means the product is covered by the European Directive 2002/96/EC.
Please contact your local authority about correct disposal for electrical and electronic
equipment. Our WEEE Registration Number is WEE/FE1471RR.
Please act according to your local rules and do not dispose of your old products with
your normal household waste. The correct disposal of your old product will help prevent
potential negative consequences for the environment and human health.

INTRODUCING THE EVOLUTION AQUA VARIPUMP
Congratulations on purchasing an Evolution Aqua Varipump.
Varipump by Evolution Aqua is a controllable pond pump, suitable for large
ponds. Output and energy consumption can be controlled at the push of a
button and the six pole, three phase motor is quiet and reliable.
Available in three sizes, Varipump is powerful enough to run the largest of
ponds and filters, and in the most demanding of situations. Suitable for use in
and out of pond.
3

4
SPECIFICATIONS
OUTLET
MAX.
FLOW
(LITRES
PER HOUR)
MAX.
FLOW
(GALLONS
PER HOUR)
MAX.
FLOW
(US GALLONS
PER HOUR)
MAX.
HEAD
MAX.
WATTS
Varipump 10000 1½” 10,000 2,200 2,642 3.1m 75W
Varipump 20000 2” 20,000 4,400 5,283 5.5m 190W
Varipump 30000 2” 30,000 6,600 7,925 5.5m 450W
DIMENSIONS
DIMENSIONS
Varipump 10000 267mm (L) x 122mm (W) x 162mm (H)
Varipump 20000 319mm (L) x 142mm (W) x 181mm (H)
Varipump 30000 370mm (L) x 155mm (W) x 205mm (H)

5
INSTALLING THE VARIPUMP
POND
Return to pond
Water Level
UV
4” Pipe
Alternative
return to pond
via waterfall
Gravity fed filter installation example shown below
Varipump can be installed either dry, as part of a gravity fed filtration system,
or submersed in water, as part of a pump fed system. When installing in
gravity fed systems ensure unions are fitted (not supplied) to enable removal of
the pump for cleaning and maintenance. We recommend using Evolution Aqua
unions (EA CODE: K82-76-55) for the 10,000 model. Use unions
(EA CODE: K82-76-66) for the 20,000 and 30,000 models.
INSTALLING THE VARIPUMP - GRAVITY FED
1. The pump suction line should be not smaller than 1½” (40mm imperial)
or 50mm true metric.
2. The suction line is to have as few bends or elbows as possible. There must not
be an air trap on the suction line.
3. Tighten the pump fittings only as much as is required to ensure a tight connection.
Excessive torque is unnecessary and may cause damage to the pump.
4. All wiring (electrical) work must be carried out by qualified electricians and must be
installed in accordance to the local codes, see information on page 2.
5. The motor must be earthed.
6. The weight of the plumbing and fittings is to be independently supported and not
carried by the pump.
7. The pump is not self-priming. Therefore, if the water level is below the pump, a
non-return valve must be installed below water level. The pump and inlet line must
be primed prior to start up. For non-flooded installations a check valve
(non-return valve) is recommended.
8. The controller must not be submerged in water.

POND
Return to pond
Hose UV
4” Pipe
Pump fed filter installation example shown below
INSTALLING THE VARIPUMP - PUMP FED
Varipump can be submersed in water, as part of a pump fed system. When installing
on pump fed systems ensure we recommend using the hosetails provided to connect
up to flexible hose (not supplied).
1. Flexible hose (not supplied) should be the widest possible diameter.
2. Extra steps on hosetails should always be sawn off and removed.
3. A hoseclip (not supplied) must always be used to hold the hose in place on
the hosetail.
4. Ensure sealing rings are fitted properly.
5. All wiring (electrical) work must be carried out by qualified electricians and must be
installed in accordance to the local codes, see information on page 2.
6. The motor must be earthed.
7. Do not let the pump run dry.
8. The controller must not be submerged in water.
6

STARTING UP THE VARIPUMP
Your varipump is supplied with an in-line digital controller. If wired correctly the
pump will switch on as soon as it is plugged in. There are three buttons on the
controller, one to turn the pump on and off, one to increase flow (and energy
consumption) and one to decrease flow (and energy consumption).
Varipump has variable flow control to enable the operator to increase or
decrease flow to their, and their filter’s exacting requirements. To adjust flow
simply press the up and down buttons on the controller to set the flow rate that
you are happy with.
7
OPERATING TEMPERATURE
The permissible temperature is > than 0˚C and < than 35˚C. The pump should
never be operated outside of these temperatures or damage may occur.

8
CLEANING THE VARIPUMP
Step 1: Hold pump by the handle and remove the inlet strainer basket
Step 2: Using a Phillips screwdriver, undo the four screws at the base of the pump body
Step 3: Remove the volute
Step 4: Clean any debris and algae from inside the volute using a brush
Step 5: Pull the impeller out of the housing by hand
Step 6: Clean the impeller with a bush. Handle carefully to avoid damage
Step 7: Clean inside the impeller housing with a brush
Step 8: Replace the screws and inlet strainer basket

9
Step 1 Step 2
Step 3 Step 4
Step 5 Step 6
Step 7 Step 8
CLEANING THE VARIPUMP

10
Excessive
Noise
Cavitation
Verify airtight plumbing on the suction plumbing especially
fittings!
Clean out leaves or other debris from basket strainer (if
applicable).
Increase pipe size where possible.
Decrease suction pipe length, reduce the number of elbows, etc.
Verify hydraulic compatibility: i.e. pump and pipe are sized for
the system.
No Power
Wired incorrectly or an RCD has tripped.
Pump has been switched off at the controller.
Flow Restriction
Ensure valves are open.
Ensure plumbing is clear, including suction strainers,
check valves, etc.
Verify non return valve orientation and direction of permitted flow.
TROUBLESHOOTING
Symptom Problem Resolution
No Flow
Insufficient Prime Prime system with water and purge all air from suction piping.
No Power
Wired incorrectly or an RCD has tripped.
Pump has been switched off at the controller.
Flow
Restriction
Ensure valves are open.
Ensure plumbing is clear, including suction strainers,
check valves, etc.
Verify non return valve orientation and direction of permitted flow.
Clean out leaves or other debris from basket strainer (if
applicable).
Air leak Fix air leaks at fittings, connections, strainer basket etc.
This typically occurs on the intake side.
System
Incompatibility
Verify hydraulic compatibility: i.e. pump & pipe are sized
for the system.
Altri manuali per Varipump 10000
1
Questo manuale è adatto per i seguenti modelli
2
Indice
Manuali Pompa per laghetto popolari di altre marche

TeichTip
TeichTip Sunsun Bio Pond Filter Set Manuale utente

Hozelock Cyprio
Hozelock Cyprio Cascade 5500 Manuale utente

Hozelock Cyprio
Hozelock Cyprio Aquaforce Series Manuale utente

HEISSNER
HEISSNER SPF 150-00 Manuale utente

AquaScape
AquaScape AQUAFORCE 4000-8000 Istruzioni per l’uso

Messner
Messner system-X 1501 Manuale utente











