DTC P0AFA - Low Cell Voltage Fault
Product Family
Fault Supported
Orion BMS [Original] (24 - 180 Cell)
YES
Orion BMS 2 (24 - 180 Cell)
YES
Orion JR (16 Cell)
YES
FAULT DESCRIPTION
This fault code is triggered when the voltage of a cell falls below 0.09 volts (90 mV). This fault can be
caused by a cell that is incorrectly set in the BMS profile as a “populated” cell, a disconnected cell wiring
harness, a very dead cell, or a wiring error. It can also indicate two or more cell voltage tap wires are
connected backwards.
IMPORTANT WARNING: If cell voltage tap wires are backwards, the cell voltage tap connectors
should be immediately disconnected from the BMS unit until the issue is corrected as permanent
damage may occur to the unit and may drain the attached cells damaging them.
NEVER LEAVE A DAMAGED ORION BMS UNIT CONNECTED TO THE BATTERY PACK.
SAFETY WARNING: Cells which have been over-charged or over-discharged may not be safe to
use even after bringing the voltage into a correct range. A cell which has previously been
over-charged or over-discharged at any time may develop internal damage, compromising the
safety of the cell. Always consult the cell manufacturer for advice on whether a cell can be safely
used after an over-charge or over-discharge event.
Document Revision: 1.0
Last Updated: 10/18/2017
Ewert Energy Systems, Inc
161 E. St Charles Rd. Carol Stream, IL 60188
Phone: (630) 868-3173

Fault Code
Fault Description
Possible Trouble Area
P0AFA
One or more cell voltages are measured as being
dangerously low or zero.
● High Voltage Battery
Assembly
● Cell Wiring Assembly
● Internal BMS Fault
FAULT BEHAVIOR
This fault will trigger Voltage Failsafe Mode which will inhibit the BMS from allowing charging or
discharging of the battery pack.
FAULT THRESHOLDS
Fault will trigger when the following condition is satisfied
(a)
(a) Cell voltage registers as dangerously low or zero volts.
One or more cells within
the pack are measured
below 90mV.
DIAGNOSTIC STEPS
1.
Immediately disconnect any loads from the pack.
If a load is malfunctioning or failing to turn off (or if a relay or contactor is stuck
ON) it may be severely over-discharging the battery pack. Make sure no
discharge loads of any kind are connected to the battery pack.
2.
Determine which cells are registering as extremely low.
The BMS will categorize which cells (by cell ID number) are registering this fault
code.
Steps to view the list of Low Cell IDs:
1) Connect to the BMS using the Orion BMS utility.
2) Click the “Diagnostic Trouble Codes” tab at the top.
Document Revision: 1.0
Last Updated: 10/18/2017
Ewert Energy Systems, Inc
161 E. St Charles Rd. Carol Stream, IL 60188
Phone: (630) 868-3173

3) View the “Low Cells” section on the far right hand side of the window.
3.
Download the freeze frame for the fault code using the BMS Utility.
The BMS will normally produce a freeze frame on the “Diagnostic Trouble
Codes” screen in the BMS Utility when this fault code occurs that contains a
comprehensive list of BMS data parameters at the time the fault occurred. It is
strongly recommended that the freeze frame be downloaded from the
BMS and saved to disk before the fault is cleared again as this data may
assist in the future if further diagnostics are required. Additionally this freeze
frame data may be requested by Technical Support if further assistance is
required.
NOTE: Only Fault Codes with a (F) next to them have freeze frame data
available for download. If there is no (F) next to the fault, there is no stored
freeze frame available and this step can be skipped.
Steps to download the Freeze Frame:
1) Connect to the BMS using the Orion BMS utility.
2) Click the “Diagnostic Trouble Codes” tab at the top.
3) Select the correct fault code by clicking on the ID on the left side of the
screen to initiate the Freeze Frame retrieval.
4) Once the retrieval process is complete, click the “Export (CSV)” button to
save the freeze frame data to the computer disk.
4.
Determine if the affected cells are supposed to be monitored.
The Orion BMS is sold in increments of 12 cells, and most applications do not
have exactly the same number of cells that the BMS supports. Because of this,
the BMS must be told which cells are connected, or “populated.” If the cell
triggering the error code is not supposed to be a “populated” cell, open the cell
population table in the BMS utility and adjust the cell population table
accordingly and upload the updated profile to the BMS. Care should be taken to
ensure that the correct profile is being modified. For profile instructions, please
refer to the Orion BMS software manual.
5.
Measure the actual cell voltages using a multimeter.
If cell voltage does not match the voltage reported in the BMS, there likely is a
wiring error and/or internal damage to the BMS unit. The BMS is designed to
recover automatically after minor wiring faults less than 24 volts, but wiring
faults more than 24 volts may damage the BMS and require service. Never
leave a damaged Orion BMS unit connected to the battery pack.
Please
contact the factory for repair information. Please refer to the Orion BMS wiring
manual for more information on proper wiring.
6.
Ensure that the cell tap wiring harnesses are properly connected.
Document Revision: 1.0
Last Updated: 10/18/2017
Ewert Energy Systems, Inc
161 E. St Charles Rd. Carol Stream, IL 60188
Phone: (630) 868-3173

Note that even though the Orion BMS units only have certain cell groups
populated internally according to the size unit purchased. Taps connected to cell
groups that are “unpopulated” internally are ignored. If the cell voltage tap
connectors are not connected in the proper order, or were connected after the
unit was powered up, reseat the connectors and clear the error codes using the
Orion BMS utility. Note that clearing error codes may clear other codes
containing useful information, so any additional information should be retrieved
before codes are cleared.
7.
Verify that the BMS has the ability to terminate discharge / loads.
If the BMS is unable to stop or inhibit charging the battery pack then it will not
be able to protect cells from being overcharged. The BMS needs the ability to
shut off any loads / discharge in order to protect the battery pack from
being over-discharged.
8.
If the problem persists, contact technical support.
If all above steps fail to determine the cause of the fault then additional support
is needed.
Please contact the company or reseller that the BMS was originally
purchased from for additional questions, warranty claims, repair
requests and technical support.
Document Revision: 1.0
Last Updated: 10/18/2017
Ewert Energy Systems, Inc
161 E. St Charles Rd. Carol Stream, IL 60188
Phone: (630) 868-3173
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Ewert Energy Systems Accessori per automobili