extronics iSCAN101 Manuale utente

Date: 27.03.2015
User Manual
Wired handheld scanner
iSCAN101

Operating Instructions_iSCAN101_001
Table of contents
1 Important Notes on Operating Instructions.....................................................................................................2
1.1Safety information..........................................................................................................................................2
1.2Notes on the Operating Instructions..............................................................................................................3
1.3General Notes of Caution..............................................................................................................................4
2 Product Information...........................................................................................................................................6
2.1 Manufacturer.................................................................................................................................................6
2.2 Explosion protection......................................................................................................................................6
2.3 Technical Data ..............................................................................................................................................7
2.4 Combinations ................................................................................................................................................9
2.5 Serial numbers..............................................................................................................................................9
2.6 Application.....................................................................................................................................................9
3 System Assembly............................................................................................................................................10
3.1 Description..................................................................................................................................................10
3.2 Cable range in System Assembly................................................................................................................11
4 Step-by-step guide on installation and operation..........................................................................................12
4.1 Step 1 - General connection of ISCAN101 handheld scanner.....................................................................12
4.2 Step 2 - Connection of ISCANPS power supply..........................................................................................13
4.3 Direct connection of the ISCAN101 handheld scanner without plug connection to the power supply with
RS232 interface - connection with cable end sleeve.........................................................................................14
4.4 Direct connection of the scanner without plug connection to the power supply with USB interface -
Connection with cable end sleeve.....................................................................................................................15
5 Attachment.......................................................................................................................................................16
5.1 EC type examination certificate: iSCAN101 ...............................................................................................16
5.2 EC type examination certificate: iSCANPS..................................................................................................18
6 Contact..............................................................................................................................................................22

Operating Instructions_iSCAN101_001 2
1 Important Notes on Operating Instructions
1.1 Safety information
Warnings are highlighted by a particular symbol and a different font colour:
Danger
Non-compliance may result in life-threatening situations.
This warning must be heeded.
Warning
This type of warning concerns dangerous situations that may result in minor injuries.
Info Important and helpful notes and information.

Operating Instructions_iSCAN101_001 3
1.2 Notes on the Operating Instructions
Before starting up the equipment please read the manual thoroughly.
The Operating Instructions contain important information on functionality as well as safety rules. If these
are not heeded, normal operations within hazardous areas cannot be guaranteed.
The notes contained in this manual are important for starting up and operating the product.
These instructions may be updated at any time. Extronics Limited reserves the right to make changes to this
document.
Before they use the product, users must ensure that they have the most up-to-date version of the operating
instructions.
To make sure this is the case, please check Extronics’ website at www.extronics.com or contact one of the
company's staff.
The drawings contained in these operating instructions are for illustration purposes only and may differ somewhat
from the actual design.
No changes may be made to the device that were not intended or approved
by Extronics Limited.
If the handheld scanner is not used properly, the operating permission for hazardous areas may lapse for the
device in question.
Non-adherence to the instructions will void any warranty.
For further information on the commission of the iSCAN101 handheld scanner you may also
wish to refer to the manual issued by SICK AG (www.SICK.com)

Operating Instructions_iSCAN101_001 4
1.3 General Notes of Caution
Caution / Notes
The devices may only be operated when fully assembled.
In hazardous areas the devices must not be wiped or cleaned with a dry
cloth!
The device must be switched off immediately if it is likely that as a
consequence of damaging impact or general peculiarities the device can no
longer be safely operated. (e.g. ingress of water or other fluids,
temperatures outside of the specified range,...)
General statutory requirements or health and safety rules and accident
prevention guidelines and environmental laws must be adhered to (e.g. the
German Occupational Health and Safety regulation).
Users must not open the device.
Users must not make any changes to the device. Components may not be
exchanged or replaced. If non-specified components are used, explosion
protection is no longer guaranteed.
Ensure safe handling with firm footing and sufficient room for movement.
If the enclosure is in any way damaged the device must be removed from
the hazardous area immediately.
In accordance with IEC 60079-19 and IEC 60079-17, operators of electrical
installation in hazardous areas are obliged to have them serviced by
qualified electricians.
Do not insert any sharp objects into the enclosure or any other openings of
the handheld barcode scanner. Any openings at the device must not be
covered or blocked.
The device and any accessories must be properly disposed of, i.e. as
legally specified, for example by a certified company.
Notes on installation Electrical plants are subject to certain regulations concerning installation
and operation (e.g. RL 99/92/EG, RL 94/9EG, or the national rules such as
IEC 60 079-14 and VDE 0100).
In the hazardous area it is the operator's responsibility to carry out any
repair and maintenance in compliance with applicable rules.

Operating Instructions_iSCAN101_001 5
Caution
on laser devices
Devices fitted with laser fall under standards US 21 CFR 1040.10 and EN
60825-1. The laser's classification is stated on a plate affixed to the device.
Class 1 lasers are deemed inherently safe during normal use, but users must
not look directly into the light source. The following declaration is required by
American and international laws:
Usage of control elements, adaptations or the use of procedures that differ from
these instructions may result in a dangerous exposure to laser beams.
Class 2 lasers use a visible low-voltage LED. As with any source of bright light,
such as the sun, the user should avoid looking directly into the light. Brief
exposure to a class 2 laser is deemed not dangerous.
Maintenance Provided the device is operated and assembled according to instructions and
the ambient requirements are being met continuous maintenance is not
necessary.
Servicing Operators of electric equipment in hazardous areas are obliged to have them
serviced by qualified electricians (IEC 60079-19 and IEC 60079-17).
Repairs Repairs may only be carried out by the manufacturer or by persons trained and
commissioned for this purpose by the manufacturer.
The device is closed ex-factory. It may only be opened in the factory by specifically trained personnel.
Software installation For instructions on how to install the software at the PC please refer to the
manual issued by SICK Vertriebs-GmbH in Düsseldorf.
Operation Before operating the device you must ensure that all necessary components are
available.

2 Product Information
2.1 ManufacturerExtronics Limited
1 Dalton Way
Midpoint 18
Middlewich, UK
CW10 0HU
Device iSCAN101
2.2 Explosion
protection
II 2G Ex ib IIC T4
II 2G Ex ib IIC T4 Gb
II 2D Ex ib IIIC T135C
II 2D Ex ib IIIC T135C Db
Protection category IP65
Nominal data Operating voltage U = 5.6V / 4.9V

2.3 Technical DataRS232 5.6V version:
maximum input voltage Ui 5.6 V
maximum input current li 480 mA
maximum input power Pi 1.25 W
maximum internal inductance Li negligible
maximum internal capacitance Ci 46 µF
Note: The input voltage in to the handheld scanner itself
is reduced by the associated connection cable
ISCAN101CAB5 or 6 from 5.6V to 4.9V.
RS232 4.9V version:
maximum input voltage Ui 4.9 V
maximum input current li 480 mA
maximum input power Pi 1.25 W
maximum internal inductance Li negligible
maximum internal capacitance Ci 102 µF
USB version:
maximum input voltage Ui 4.9 V
maximum input current li 480 mA
maximum input power Pi 1.25 W
maximum internal inductance Li negligible
maximum internal capacitance Ci 102 µF

Operating Instructions_iSCAN101_001 8
Technical Data
(Scan engine) Light source: Visible red light, 630nm
LED safety: LED classification acc. to DIN EN 60825-1
Scan rate: 500 scans per second
Reader distance: 50mm to 800mm (0.5mm)
Dimensions 104 x 76 x 185 mm (length x width x height)
Ambient temperature -20°C to +50°C
Storage temperature -30°C to +70°C
Weight ca. 200g (without connection cable)
Test certificate IBExU12ATEX1120
Optional interfaces RS-232 TTL / USB
Terminal assignment
(Handheld scanner) USB cable
USB/D+ green
USB/D- white
GND black
+UB brown

Operating Instructions_iSCAN101_001 9
2.4 Combinations
RS232/RS422
used with connection cable ISCAN101CAB1 or 2
and only for connection to power supply ISCANPS1 or 3
USB version
used with connection cable ISCAN101CAB3 or 4
and only for connection to power supply ISCANPS2 or 4
All wired handheld scanners in Stacked PDF version (iSCAN101PDF)
can be equally combined.
2.5 Serial numbers
Serial key: year of manufacture serial number
2 numbers 4 numbers
Example: 130001
2.6 Application
The scanner is a handheld device.
Its purpose is portable capture and direct transfer of data in hazardous areas. The device has been designed for
use in hazardous area zones 1 and 21.