Fasep B222 Manuale utente

www.fasep.it
User’s MANUAL
B222 - B212 - B112

Fasep 2000 srl Rev. 1.8
Balatron 222/212: User’s Manual 23 January 2020
For any information, please contact: www.fasep.it
e-mail: [email protected]
FASEP 2000 srl
Via Faentina 96
50032 Ronta (Fi) Italy
Tel. #39 055 8403126
Fax #39 055 2691906 i
B222
B212
BALATRON 222/212
USER’S MANUAL

Fasep 2000 srl Rev. 1.8
Balatron 222/212: User’s Manual 23 January 2020
ii
WARNING
.This document contains information which is the property of FASEP 2000 srl and all rights are reserved. This manual shall not be
photocopied or reproduced in any way without the prior written consent of FASEP 2000 srl.
.FASEP 2000 srl reserves the right to revise products firmware, software or documentation without obligation to notify any person
or organization. The information contained in this document is subject to change without warning.
.Prior of the installation of the unit described in this manual, user should read this manual carefully to be instructed properly on
installation, use and maintenance of the unit.
.Failing to read this manual and operate accordingly may cause damage to the user or the unit.
.FASEP 2000 srl shall not be responsible for inconvenience, breakdown, accidents due to uncomplete knowledge of this manual
or uncomplete application of recommendations described in this manual.
.FASP2000srlshallnotberesponsiblefor inconvenience, breakdown, accidents due to unauthorized modifications of the unit, use
of non-original or unauthorized accessories (see Accessories listing in this manual for a list of original accessories available for this
model).
.FASEP 2000 srl shall not be responsible for any inconvenience, breakdown, accidents caused directly or indirectly by not
qualified service. Service to any parts by not qualified persons will void warranty and will void any right of the owner of
the unit.
SYMBOLS AND CONVENTIONS
To speed the retrieval of main information and make easy to understand the instructions, this manual uses the following typing
conventions:
<NAME OF THE PUSH BUTTON> Used to indicate name of push-buttons on the control panel.
DISPLAY Used to indicate text or number visible on the displays on the control panel.
ADVICES Contain useful advices or solutions, evidence d with respect to the rest of the text.
NOTE Notes contain important information, evidenced to the rest of the text.
WARNING Warning messages appears corresponding to procedures that, if not properly observed,
may lead to loose of data or cause damage to the unit.
!CAUTION Caution messages appears corresponding to procedures that, if not properly observed,
may cause injuries to the user.

Fasep 2000 srl Rev. 1.8
Balatron 222/212: User’s Manual 23 January 2020
iii
ORIGINAL INSTRUCTIONS
TABLE OF CONTENTS
WARNING ...........................................................................................ii
SYMBOLSANDCONVENTIONS .........................................................................ii
TABLEOFCONTENTS ................................................................................ iii
1 PRESENTATION ............................................................................1-1
1.0 Intended Use .......................................................................1-1
1.1 Definitions .........................................................................1-1
2 INSTALLATION .............................................................................2-2
2.1 Movingtheunit......................................................................2-2
2.2 Assemblingtheunit ..................................................................2-2
2.3 Installation .........................................................................2-2
2.4 ElectricalHookup....................................................................2-2
3 USETHECONTROLPANEL ..................................................................3-1
3.1 Meaning of keys at the keyboard ........................................................3-1
3.2 Meaning of Led Indicators .............................................................3-1
4 CALIBRATION ..............................................................................4-1
4.1 How to calibrate the Wheel Balancer (USER) ..............................................4-1
4.2 How to check the calibration of Wheel Balancer (USER) .....................................4-2
4.3 ALU-SEcalibration(USER) ............................................................4-3
5 MEASUREMENTANDCORRECTIONOFUNBALANCE.............................................5-1
5.1 Placing the wheel rim on the wheel balancer ...............................................5-1
5.2 How to compensate unbalance of flanges using AFC function (optional for B212) ..................5-1
5.3 Input of Rim Dimensions ..............................................................5-2
5.4 Detecting and correcting unbalance .....................................................5-4
5.5 How to apply the weight using ALU-SE indicator ............................................5-4
6 HOWTOOPTIMIZEUNBALANCEOFTHEWHEEL ................................................6-1
7 HOW TO USE SPLIT WEIGHT FUNCTION .......................................................7-1
8 SPECIAL FUNCTIONS MENU ..................................................................8-1
8.1 Enterinthespecialfunctionsmenu......................................................8-1
8.2 Diagnostic program of sensors .........................................................8-1
8.3 Statisticprogram ....................................................................8-1
8.4 UserSetup.........................................................................8-1
APPENDIX ................................................................................... i
A: TechnicalData ................................................................................ i
B: Environmental Data, Safety Features and Requirements ............................................... i
C: Errors and Malfunctions recognized by the Computer .................................................. i

Fasep 2000 srl Rev. 1.8
Balatron 222/212: User’s Manual 23 January 2020
1-1
1 PRESENTATION
1.0 Intended Use
This unit is designed to measure and correct static and dynamic unbalance of vehicle wheel, the dimension and weight
of which are within the working range of the machine (see “Technical Data”appendix for reference)
This unit is meant for a professional use. Operator shall be properly trained before use. Training Course is not included
in the price of the unit and must be purchased separately.
This unit is designed for indoor use only ( see “Environmental Data”appendix for reference).
!CAUTION This unit is designed to spin vehicle wheels only, within the range of dimensions and weight
approved (see “Technical Data”appendix for reference). Special adaptors suit this purpose. Do not
attempt to use the machine to spin anything else. Unproper locking may cause the part being spun
to be ejected, causing damage to the unit itself, the operator or anything in the in the neighborhood.
1.1 Definitions
1. 3D console
2. Nameplate label
3. Flange holders
4. Weights and tolls compartments
5. Foot-pedal brake

Fasep 2000 srl Rev. 1.8
Balatron 222/212: User’s Manual 23 January 2020
2-2
2 INSTALLATION
2.1 Moving the unit
WARNING When the unit has to be moved: never lift balancer by motor shaft or by neighborhood of it.
2.2 Assembling the unit
Forease of transportation, thewheelbalancer might bedisassembledinto units. If necessary,assembling instruction are
provided within each package.
2.3 Installation
The wheel balancer must be installed on a firm and level ground.
NOTE The machine must be secured to the floor. Using four holes in the base and anchor bolts provided.
2.4 Electrical Hookup
!CAUTION Failure to follow these instructions can results in damage to unit or create an electrical hazard and
will void warranty.
2.4.1 Electrical hookup is to be provided by a qualified electrician.
2.4.2 Afusiblewall-mountedswitchboxisrequiredattheinstallationsite.Thisswitchshouldprovideon-offcontrolandoverload
protection for your wheel balancer only. The switchbox should be fused with time-delay fuse(s) in accordance with the
power rating specified on your wheel balancer.
2.4.3 Electrical connection of the machine should be by plug connectors.
2.4.4 The balancer must be effectively connected to ground. The electric cord is regularly provided with a ground
t terminal.
2.4.5 MakesurethatPowerRateSpecificationsforyourwheelbalancer(refertonameplateonthewheelbalancer)complywith
those provided by the external power source.
!CAUTION Afterelectrical hookuphasbeen performedunit isreadyto operate.Always observepertinentsafety
precautions when operating the unit (see Appendix tables for an overview of relevant Safety
requirement).

Fasep 2000 srl Rev. 1.8
Balatron 222/212: User’s Manual 23 January 2020
3-1
FIG.8: Panel Balatron 2000
3 USE THE CONTROL PANEL
3.1 Meaning of keys at the keyboard
These instructions apply to Normal Operating Mode. Other function maybe activated by these keys in other operating modes (see
Special Functions).
<MODE>: ................................................ Toselectbalancingtype:Dynamic-Static-Alu.
<SET>: ........................................................................ Confirmselection
9 <OPER>: ....................................................... ToselectOperator1orOperator2.
10 <FINE>: ................................................................ Toselectreading scale.
11 <FUNC>: .............................................................Toselectspecificfunctions
<START-STOP>: ........................................................Starts-stopswheel spinning.
6 <DISTANCE -/+>: ....................................................... Setinternalsidemeasure.
7 <WIDTH -/+>: ................................................................ Setwidthmeasure.
8 <DIAMETER -/+> .......................................................... Setdiametermeasure.
3.2 Meaning of Led Indicators
1-4: ............................................................. indicatelocationofweightrequired.
2-5: ............................................................. indicateamount of weight required.
3: ...........................................................indicatetheapplication point of weights.

Fasep 2000 srl Rev. 1.8
Balatron 222/212: User’s Manual 23 January 2020
4-1
FIG.10
FIG.11
FIG.12
4 CALIBRATION
4.1 How to calibrate the Wheel Balancer (USER)
NOTE the following symptoms indicate need for calibration:
a) check calibration program fails.
b) constant low or high weight readings.
c) indicated point of unbalance constantly wrong
d) more than 2 spins required to balance wheels repeatedly
Switch on the wheel balancer.
Press <SET> when SOF X.XX
(software version) is displayed.
ATTENTION select mode
CAL USR
Spin the empty shaft ( Fig. 9).
Place a wheel on the flange ( Fig. 10).
Put the calibration weight (Fig. 11).
End of calibration.
Press <MODE/ESC> to return to normal
balancing mode.
NOTE technical calibration is only available for qualified personnel.

Fasep 2000 srl Rev. 1.8
Balatron 222/212: User’s Manual 23 January 2020
4-2
FIG.14
FIG.15
4.2 How to check the calibration of Wheel Balancer (USER)
ATTENTION select mode
CAL USR
Press <+/-> to select CAL TEST
Place a wheel on the flange ( Fig. 13).
Put the calibration weight ( Fig. 14).
Press 10 <FINE> to see actual values.
160-0 (±3) is correct result.
When all LED (left side) are lit,
calibration weight must be at exactly 6
o’clock.
If no, press 11 <FUNC> to calibrate
position.
Turn the wheel until the calibration
weight is located at 6 o’clock.
Press <SET> to calibrate.
Press <MODE/ESC> to return to normal
balancing mode.
NOTE technical calibration is only available for qualified personnel.
FIG.16

Fasep 2000 srl Rev. 1.8
Balatron 222/212: User’s Manual 23 January 2020
4-3
4.3 ALU-SE Calibration (USER)
Switch on the wheel balancer.
Press <SET> when SOF X.XX
(software version) is displayed.
ATTENTION select mode
CAL USR
Put the rod in 0 position (Fig. 17)
Put the rod in internal side of flange
(Fig.18)
Put the rod in the internal side of the
rim (Fig.19)
Select the wheel diameter
Press <MODE/ESC> to return to
normal balancing mode.
NOTE technical calibration is only available for qualified personnel
FIG.18
FIG.19
FIG.20
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Fasep Equilibratrice

Fasep
Fasep VIDEOTRONIC V548.G4 Manuale utente

Fasep
Fasep VIDEOTRONIC V688.G3 Manuale utente

Fasep
Fasep BALATRON B110 Manuale utente

Fasep
Fasep VIDEOTRONIC V788.G3 Manuale utente

Fasep
Fasep RGU 56 XL Istruzioni operative

Fasep
Fasep VIDEOTRONIC V653.G2 Manuale utente

Fasep
Fasep BALATRON B150 Manuale utente

Fasep
Fasep B350.G3 Manuale utente

Fasep
Fasep VIDEOTRONIC V644.G3 Manuale utente