Feig Electronic IBID i-scan ID ISC.MR200 Manuale utente

MANUAL
final
public (B)
2008-05-26
H40801-5e-ID-B.doc
OBI
D
i-scan
®
ID ISC.MR200
Standard-Reader
from Firmware-Version 1.12

OBID i-scan System-Manual ID ISC.MR200
FEIG ELECTRONIC GmbH Page 2 of 144 H40801-5e-ID-B.doc
Note
!Copyright 2004-2008 by
FEIG ELECTRONIC GmbH
Lange Strasse 4
D-35781 Weilburg-Waldhausen
Tel.: +49 6471 3109-0
http://www.feig.de
With the edition of this manual, all previous editions become void. Indications made in this manual may be changed without
previous notice.
Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without
express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent
or the registration of a utility model or design.
Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does
not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages
ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are
always grateful for your useful tips.
The installation instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC
GmbH does not give any guarantee promise for perfect function in cross environments.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no
representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent
rights nor the rights of others.
OBID®is registered trademark of FEIG ELECTRONIC GmbH.
OBID i-scan®is registered trademark of FEIG ELECTRONIC GmbH.
I-Code®is registered trademarks of Philips Electronics N.V.
General information's regarding this manual
"If bits within one byte are filled with "-", these bit spaces are reserved for future extensions or for internal
testing- and manufacturing-functions. These bit spaces must not be changed, as this may cause faulty op-
eration of the Reader.
"The following figure formats are used:
0...9: for decimal figures
0x00...0xFF: for hexadecimal figures,
b0...1 for binary figures.
"The hexadecimal value in brackets "[ ]" marks a control byte (command).

OBID i-scan System-Manual ID ISC.MR200
FEIG ELECTRONIC GmbH Page 3 of 144 H40801-5e-ID-B.doc
Content
Revision History of documentation...........................................................................................8
Abbreviations ..............................................................................................................................9
1. Data Transmission between OBID i-scan®ID ISC.MR200 and Host 10
1.1. Configuration Commands and Control Commands ......................................................10
1.2. ISO15693 Host Commands ..............................................................................................11
1.3. Buffered Read Mode .........................................................................................................14
1.4. Notification Mode ..............................................................................................................15
1.5. Scan Mode ........................................................................................................................16
2. Interface 18
2.1. Protocol Frames of TCP/IP protocol ...............................................................................18
2.2. Serial Data Format and Protocol Frames........................................................................19
2.3. CRC16 Calculation Algorithm ..........................................................................................21
3. Configuration Parameters (CFG) 22
3.1. CFG0: Passwords ............................................................................................................24
3.3. CFG1: Interface .................................................................................................................26
3.4. CFG2: Inputs / Outputs general .......................................................................................30
3.4.1. Dedicated Input / Output Functions.............................................................................32
3.5. CFG3: RF-Interface ...........................................................................................................33
3.6. CFG4: Transponder Parameters......................................................................................35
3.7. CFG5: Anticollision...........................................................................................................37
3.8. CFG6 - 9: Reserved ...........................................................................................................39
3.9. CFG10: Trigger ..................................................................................................................40
3.10. CFG11 Read Mode Data..................................................................................................42

OBID i-scan System-Manual ID ISC.MR200
FEIG ELECTRONIC GmbH Page 4 of 144 H40801-5e-ID-B.doc
3.11. CFG12: Read Mode - Filter .............................................................................................44
3.12. CFG13 Scan Mode...........................................................................................................45
3.13. CFG14: Reserved ............................................................................................................48
3.14. CFG15: Antenna Multiplexing ........................................................................................49
3.15. CFG16: Persistence Reset .............................................................................................51
3.16. CFG17-19: Reserved .......................................................................................................52
3.17. CFG20: RF-Parameter.....................................................................................................53
3.18. CFG21: Reserved ............................................................................................................54
3.19. CFG22 + CFG23: Selection Mask (only I-Code UID and EPC Transponder) ..............55
3.20. CFG24-29: Reserved .......................................................................................................57
3.21. CFG40: LAN Settings, Part 1 (not used for ID ISC.MR200-A / -W) ..............................58
3.22. CFG41: LAN Settings, Part 2 (not used for ID ISC.MR200-A / -W) ..............................59
3.23. CFG42: WLAN Settings, Part 1 (not used for ID ISC.MR200-A / -E / -EP)...................60
3.24. CFG43: WLAN Settings, Part 2 (not used for ID ISC.MR200-A / -E / -EP)...................61
3.25. CFG44 WLAN Security Settings, Part 1 (not used for ID ISC.MR200-A / -E / -EP).....62
3.26. CFG45 WLAN Security Settings, Part 2 (not used for ID ISC.MR200-A / -E / -EP).....63
3.27. CFG49: Notification Channel (not used for ID ISC.MR200-A) .....................................64
3.28. CFG63: Customer Parameter ........................................................................................66
4. Protocols for Reader Configuration 67
4.1. [0x80] Read Configuration ...............................................................................................67
4.2. [0x81] Write Configuration ...............................................................................................68
4.3. [0x82] Save Configuration................................................................................................69
4.4. [0x83] Set Default Configuration (Reset) ........................................................................70
5. Protocols for Reader Control 71
5.1. [0x52] Baud Rate Detection..............................................................................................71

OBID i-scan System-Manual ID ISC.MR200
FEIG ELECTRONIC GmbH Page 5 of 144 H40801-5e-ID-B.doc
5.2. [0x55] Start Flash Loader .................................................................................................71
5.3. [0x63] CPU Reset ..............................................................................................................72
5.4. [0x64] System Reset .........................................................................................................72
5.5. [0x65] Get Software Version ............................................................................................73
5.6. [0x66] Get Reader Info ......................................................................................................75
5.7. [0x69] RF Reset .................................................................................................................77
5.8. [0x6A] RF ON/OFF.........................................................................................................77
5.9. [0x6D] Get Noise Level .....................................................................................................78
5.10. [0x6E] Reader Diagnostic...............................................................................................79
5.11. [0x71] Set Output ...........................................................................................................81
5.11.1. Set Output Examples.................................................................................................83
5.12. [0x74] Get Input ..............................................................................................................83
5.13. [0x85] Set System Timer.................................................................................................84
5.14. [0x86] Get System Timer ................................................................................................84
5.15. [0xA0] Reader-Login .......................................................................................................85
6. Protocols for ISO15693 Host Commands 86
6.1. [0xB0] Host commands for ISO15693 Mandatory and Optional Commands...............87
6.1.1. [0x01] Inventory ...........................................................................................................88
6.1.2. [0x02] Stay Quiet .........................................................................................................91
6.1.3. [0x22] Lock Multiple Blocks .........................................................................................92
6.1.4. [0x23] Read Multiple Blocks ........................................................................................93
6.1.5. [0x24] Write Multiple Blocks ........................................................................................95
6.1.6. [0x25] Select................................................................................................................97
6.1.7. [0x26] Reset to Ready .................................................................................................98
6.1.8. [0x27] Write AFI...........................................................................................................99
6.1.9. [0x28] Lock AFI..........................................................................................................100
6.1.10. [0x29] Write DSFI ....................................................................................................101
6.1.11. [0x2A] Lock DSFI.....................................................................................................102

OBID i-scan System-Manual ID ISC.MR200
FEIG ELECTRONIC GmbH Page 6 of 144 H40801-5e-ID-B.doc
6.1.12. [0x2B] Get System Information................................................................................103
6.1.13. [0x2C] Get Multiple Block Security Status ...............................................................105
6.2. [0xBF] ISO15693 Transparent Command ....................................................................106
7. Special Commands 109
7.1 [0x18] Destroy (only I-Code EPC/UID Transponders) ....................................................109
Supported ISO15693 Host commands 110
7.1. Supported ISO15693 Host commands for ISO15693 Transponders ......................110
7.1.1. EM Microelectronics (EM4034) .................................................................................110
7.1.2. EM Microelectronics (EM4135) .................................................................................111
7.1.3. Fujitsu (MB89R116).................................................................................................112
7.1.4. Fujitsu (MB89R118).................................................................................................113
7.1.5. Fujitsu (MB89R119).................................................................................................114
7.1.6. Infineon (my-d page mode) 0x60..............................................................................115
7.1.7. Infineon (ISO address mode) 0xE0 ..........................................................................116
7.1.8. Infineon (My-d Light).................................................................................................117
7.1.9. NXP (I-Code SLI).......................................................................................................118
7.1.10. NXP (I-Code SLI-S) .................................................................................................119
7.1.11. NXP (I-Code SLI-L) .................................................................................................120
7.1.12. STMicroelectronics (LRI512).................................................................................121
7.1.13. STMicroelectronics (LRI64)...................................................................................122
7.1.14. STMicroelectronics (LRI2k / LRIS2k) ....................................................................123
7.1.15. Texas Instruments (Tag-it HFI Pro / Standard) .....................................................124
7.1.16. Texas Instruments (Tag-it HFI Plus)......................................................................126
8. Supported ISO15693 Host commands for I-Code EPC Transponders 128
9. Supported ISO15693 Host commands for I-Code UID Transponders 129
10. Protocols for Buffered Read Mode 130
10.1. The Buffered Read Mode Procedure ...........................................................................130
10.2. Transponder Access in the Buffered Read Mode ......................................................131

OBID i-scan System-Manual ID ISC.MR200
FEIG ELECTRONIC GmbH Page 7 of 144 H40801-5e-ID-B.doc
10.3. [0x22] Read Buffer ........................................................................................................132
10.4. [0x31] Read Data Buffer Info ........................................................................................135
10.5. [0x32] Clear Data Buffer ...............................................................................................136
10.6. [0x33] Initialize Buffer ...................................................................................................136
ANNEX 137
ANNEX A: Codes of Transponder Types ..............................................................................137
ANNEX B: Time Behavior of the Asynchronous Interface ..................................................138
ANNEX C: Time Behavior of ISO15693 Host Commands....................................................139
Time Behavior for [0x01] Inventory and ISO15693 Transponders .......................................140
ANNEX D: Index of Status Bytes ...........................................................................................141
ANNEX E: Codes of Reader Types ........................................................................................143
ANNEX I: Examples for Read Data .......................................................................................144
ISO15693 Host Command (DB-Size of the Transponder = 4 bytes)....................................144
ISO15693 Host Command (DB-Size of the Transponder = 8 bytes)....................................144

OBID i-scan System-Manual ID ISC.MR200
FEIG ELECTRONIC GmbH Page 8 of 144 H40801-5e-ID-B.doc
Revision History of documentation
Revi-
sion
Date Page Description
0e 09.09.04 Initial version
75 New Protocol: [0x66] Get Reader Info
33 CFG3: RF-Interface, New Transponder Driver
141 New status message [0x17] Firmware activation required:
109 [0x18] Destroy (only I-Code EPC/UID Transponders)
129 Supported ISO15693 Host commands for I-Code UID Transponders
1e 21.04.05
143 Codes of reader types
127 New Transponder EM4135 supported
14 Integration of Buffered Read Mode
2e
26 42 44 Configuration of Buffered Read Mode
130 Buffered Read Mode Commands
58 LAN Settings
02.11.05
60 WLAN Settings
3e 09.06.06
42
45
Configuration of Scan Mode
15 Integration of Notification Mode
64 Configuration of Notification Mode
25.09.06
49 Supported Antenna Multiplexing
4e
04.10.06 40 Configuration of Trigger
24 Configuration of Reader Login
5e 26.05.08
66 Configuration of Costumer Parameter

OBID i-scan System-Manual ID ISC.MR200
FEIG ELECTRONIC GmbH Page 9 of 144 H40801-5e-ID-B.doc
Abbreviations
ADR Address
ASK Amplitude Shift Keying
CB Config Block
CFG Configuration Parameter Block
CRC Cyclic Redundancy Check
DB data block
DIP Dual Inline Plastic
FIFO First in First out
frq Frequency
FSK Frequency Shift Keying
h Hour
Hz Hertz
ID Identification
IN Input
LEN Length
LOC Location
LSB Least Significant Byte
min Minutes
ms Milliseconds
MSB Most Significant Byte
N Number
OUT Output
R/W Read / Write Access
RD Read
REL Relay
RF Radio Frequency
RSSI Received Signal Strength Indicator
RTC Real Time Clock
TAB Table
TR Transponder
TS Timeslot
UID Unique Identifier (read only Serial Number)
WO Write Only Access
WR Write

OBID i-scan System-Manual ID ISC.MR200
FEIG ELECTRONIC GmbH Page 10 of 144 H40801-5e-ID-B.doc
1. Data Transmission between OBID i-scan®ID ISC.MR200 and Host
Different ways of data transmission between OBID i-scan®Readers and host (terminal, PC) are pos-
sible. The ISO15693Host Commands are used for the data exchange between Transponder and
host, whereas the Configuration Commands and the Control serves for adapting the Reader pa-
rameters to the individual range of applications. The following chart shows which method of data
transmission is supported by which interface:
asynchronous interface
(RS232 / RS485)
Configuration Commands #
Reader Control Commands #
ISO15693 Host Commands #
1.1. Configuration Commands and Control Commands
This method of data transmission is used for Reader configuration and the diagnosis via the asyn-
chronous interface or Ethernet Interface
The Reader-configuration parameters will be stored in the Reader memory. To store the current con-
figuration during a power down of the Reader the Reader-Configuration has to be stored in the
EEPROM. After power up the Reader reads the configuration out of the EEPROM.
The Reader control is immediately processed and the response from the Reader contains status or
data information of the control command.
Host (Terminal / PC / ....) Reader
parameter- / control command $parameter received and stored / control
command processed
yes no
%status /
data
error status
%