Feig Electronic ID ISC.LRU3000 Manuale utente

IDENTIFICATION
M21015-4e-ID-B
Installation
ID ISC.LRU3000 / ID ISC.LRU3500
UHF Long Range Reader

IDENTIFICATION
ID ISC.LRU3000 / LRU3500
Note
Page 2 of 30
Note
Note
© Copyright by
FEIG ELECTRONIC GmbH
Lange Strasse 4
D-35781 Weilburg (Germany)
Tel.: +49 6471 3109-0
http://www.feig.de
identification-support@feig.de
With the edition of this document, all previous editions become void. Indications made in this manual may be
changed without previous notice.
Copying of this document and giving it to others and the use or communication of the contents thereof are
forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved
in the event of the grant of a patent or the registration of a utility model or design.
Composition of the information in this document has been done to the best of our knowledge.
FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this
manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since,
despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The instructions given in this manual are based on advantageous boundary conditions.
FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments
and does not give any guarantee for the functionality of the complete system which incorporates the subject
of this document.
FEIG ELECTRONIC GmbH calls explicit attention that devices which are subject of this document are not
designed with components and testing methods for a level of reliability suitable for use in or in connection
with surgical implants or as critical components in any life support systems whose failure to perform can
reasonably be expected to cause significant injury to human health. To avoid damage, injury or death the
user or application designer must take reasonably prudent steps to protect against system failures.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this
document and makes no representation that they are free of patent infringement. FEIG ELECTRONIC GmbH
does not convey any license under its patent rights nor the rights of others.
Pos: 7/ Steuermodule/------------ Seitenumbruch ------------ @ 0\mod_145208328 1983_0.docx @ 10032 @ @ 1

IDENTIFICATION
ID ISC.LRU3000 / LRU3500
Contents
Page 3 of 30
Contents
Contents
1Safety Instructions / Warning - Read before start-up ! 5
2Performance Features of Reader Family ID ISC.LRU3000 6
2.1 Performance features........................................................................................................6
2.2 Available Reader types .....................................................................................................6
2.3 Available Accessories.......................................................................................................6
3Installation 7
4Terminals 8
4.1 Antenna Connection..........................................................................................................9
4.2 Power Supply................................................................................................................... 10
4.2.1 Power Supply via connection X1..........................................................................10
4.2.2 Power Supply via Power over Ethernet (PoE) ......................................................11
4.3 Interfaces .........................................................................................................................12
4.3.1 Ethernet Interface on connector X2 (10/100Tbase)..............................................12
4.3.2 USB Interface on connector X3 (Host Kommunikation)........................................12
4.3.3 USB Host Interface on connector X4....................................................................13
4.3.4 RS232 Interface on connector X6.........................................................................13
4.3.5 RS485 Interface on connector X6.........................................................................14
4.3.6 Data-Clock Interface on connector X5 for Scan Mode only................................... 15
4.4 Digital Inputs on connector X5.......................................................................................17
4.5 Outputs on connector X5................................................................................................19
4.5.1 Digital outputs on connector X5............................................................................19
4.5.2 Relay outputs on connector X5 ............................................................................ 20
5Operating and Display Elements 21
5.1 Status LEDs..................................................................................................................... 21
5.2 Reset Push Buttons.........................................................................................................22
5.3 Reader Power adjustment............................................................................................... 23
5.3.1 EU-Reader according to EN302 208....................................................................23

IDENTIFICATION
ID ISC.LRU3000 / LRU3500
Contents
Page 4 of 30
6Technical Data 25
7Radio Approval 27
7.1 Europe (CE)...................................................................................................................... 27
7.2 USA (FCC) and Canada (IC)............................................................................................28
7.2.1 USA (FCC) and Canada (IC) warning notices ......................................................28
7.2.2 Label Information .................................................................................................29
7.2.3 Installation with FCC / IC Approval....................................................................... 29
7.2.4 USA (FCC) and Canada (IC) approved antennas.................................................29
Annex A: Accessories Following optional accessories are available:...............................30
=== Ende der Liste für Te xtmarke Note ===

IDENTIFICATION
ID ISC.LRU3000 / LRU3500
1 Safety Instructions
Page 5 of 30
1 Safety Instructions
►The device may only be used for the intended purpose designed by for the manufacturer.
►The operation manual should be conveniently kept available at all times for each user.
►Unauthorized changes and the use of spare parts and additional devices which have not been sold or
recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized
measures shall exclude any liability by the manufacturer.
►The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the
device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in
the manual or automatically set parameters for a device or for an incorrect application of a device.
►Repairs may only be executed by the manufacturer.
►Installation, operation, and maintenance procedures should only be carried out by qualified personnel.
►Use of the device and its installation must be in accordance with national legal requirements and local
electrical codes .
►When working on devices the valid safety regulations must be observed.
►This device is not suitable to be used in places where children are present. Prevent children access to
the device.
►Equipment is intended for use only in restricted access area.
►Special advice for carriers of cardiac pacemakers:
Although this device doesn't exceed the valid limits for electromagnetic fields you should keep a
minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in an
immediate proximity of the device respective the antenna for some time.

IDENTIFICATION
ID ISC.LRU3000 / LRU3500
2 Performance Features of
Reader Family ID ISC.LRU3000
Page 6 of 30
2 Performance Features of Reader Family ID ISC.LRU3000
2.1 Performance features
The Reader has been developed for reading passive data carriers, so-called „Smart Labels“, using an
operating frequency in the UHF range.
2.2 Available Reader Types
The following Readers are available:
Table 1: Available Reader Types
Reader type
Description
ID ISC.LRU3500-EU
Device version for Europe with PoE
ID ISC.LRU3000-EU
Device version for Europe without PoE
ID ISC.LRU3500-FCC
Device version for USA with PoE
ID ISC.LRU3000-FCC
Device version for USA without PoE
2.3 Available Accessories
The following optional accessories are currently available:
Table 2: Optional Reader Accessories
Reader type
Description
ID ISC.LR.CSC-IP64 Connector
Sealing Cap
Protection cap for IP 64
Art.No.: 3558.000.00
ID ISC.LRU3x00-MS Mounting Rail
Set
Rail Mounting Set for ID ISC.LRU3000/3500
Art.No.: 3831.000.00
See also: ANNEX-A

IDENTIFICATION
ID ISC.LRU3000 / LRU3500
3 Installation
Page 7 of 30
3 Installation
The Reader is designed for wall-mount, including outdoors. Holes for mounting on a wall are provided in the
housing.
It is not necessary to open the reader housing mounting.
Fig. 1: Installation Drawing

IDENTIFICATION
ID ISC.LRU3000 / LRU3500
4 Terminals
Page 8 of 30
4 Terminals
On the lower side of the reader housing the different cable connectors are positioned. Figure 2 shows the
arrangement of the connectors and table 3 shows which connection for the different cables are used for. Table
4 shows the available push buttons.
X2 X3 X4
X5
X6
T1 T2
X1 ANT1 ANT2 ANT3 ANT4
Fig. 2: Connection Overview
Table 3: Connection terminals
Connector
Description
ANT 1-4
Connection of the external antennas (Impedance 50)
X1
Power supply 24VDC +-5%
X2
10/100Tbase network connection with RJ-45 (with PoE)
X3
USB interface for host communication
X4
USB Host Interface on connector X4
X5
Digital input and output and relay output
X6
RS232 / 485 interface
Table 4: Push button function
Push button
Description
T1
Internal push button for complete configuration reset
T2
External push button for CPU-Reset

IDENTIFICATION
ID ISC.LRU3000 / LRU3500
4 Terminals
Page 9 of 30
4.1 Antenna Connection
The external SMA antenna connectors are positioned on the lower side of the reader.
The maximum tightening torque for the SMA sockets is 0.45 Nm (4.0 lbf in).
CAUTION:
Exceeding the tightening torque will destroy the plug.
Table 5: External antenna connection
Terminal
Description
ANT 1 - 4
Connection for external antennas (input impedance 50)
Fig. 3: External antenna connection ANT1-4 and X1 for the power supply
CAUTION:
A direct connection of an antenna to an antenna output with activated DC Voltage (24 VDC, 500 mA)
may damage the antenna.

IDENTIFICATION
ID ISC.LRU3000 / LRU3500
4 Terminals
Page 10 of 30
4.2 Power Supply
4.2.1 Power Supply via connection X1
The supply voltage of 24 V DC has to be connected to Terminal X1
Table 6: Pin assignment for power supply
Terminal
Abbreviation
Description
X1 / Pin 1
VDC
Vcc –supply voltage 24VDC +-5%
X1 / Pin 2
GND
Ground –supply voltage
Fig. 4: Connection for the power supply
CAUTION:
The reader has to be supplied by a limited power supply (e.g. NEC Class 2/LPS power supply)
according IEC EN 60950-1 chapter 2.5, only.
Reversing the polarity of the supply voltage may destroy the device.
Each reader has to be supplied by a separate external power supply.
An operation of an ID ISC.LRU3500 via an external power supply and Power over Ethernet (PoE)
at the same time is not recommended and can cause interferences during operation.
Altri manuali per ID ISC.LRU3000
1
Questo manuale è adatto per i seguenti modelli
5
Indice
Altri manuali Feig Electronic Controllori di accesso IP