FeverFinder FFim100 Manuale utente

FFim100
User Manual
Professional thermal imager


FFim100 User Manual
FFim100 User Manual
3
Preface
Thank you for purchasing this brand new FFim100 thermal imager. In order
to use this product safely and correctly, please read this manual thoroughly,
especially the safety notes.
After reading this manual, it is recommended to keep the manual at an
easily accessible place, preferably close to the device, for future reference.
Limited Warranty and Liability
FeverFinder guarantees that the product is free from any defect in material
and workmanship within one year from the purchase date. This warranty
does not apply to damage caused by accident, negligence, misuse,
modification, contamination or improper handling. The dealer shall not be
entitled to give any other warranty on behalf of FeverFinder. If you need
warranty service within the warranty period, please contact your seller
directly.
This product is intended to be used as a screening tool in conjunction with
health and safety procedures in environments and situations where fever is
considered an indicator on which further actions are based. How the
temperature readings are to be interpreted depends on context and on the
defined procedures, but on their own these readings cannot be taken as a
reliable indicator of infection or disease.
This product is not a medical device. It is not intended or designed to be
used for diagnosis, prevention, monitoring, treatment or alleviation of
disease.
FeverFinder and its dealers, partners and suppliers will not be liable for any
special, indirect, incidental or subsequent damage or loss caused by using
this device.
2

FFim100 User Manual
4

FFim100 User Manual
FFim100 User Manual
5
Table of Contents
1. Safety Instructions .......................................................................... 6
2. Structure .......................................................................................... 7
3. Display ............................................................................................. 8
4. Power On/Off .................................................................................. 8
5. Menu Introduction .......................................................................... 9
6. Operating Instructions ................................................................... 10
7. USB Communication ...................................................................... 18
8. Specifications ................................................................................. 19
9. Maintenance ................................................................................. 21
10. Common Emissivity ....................................................................... 21

FFim100 User Manual
6
1. Safety Instructions
To ensure proper use of this product, please read the instructions carefully
before using.
• The optimal measuring distance for this product is 1 meter.
• To ensure measurement accuracy, please use the product in an operating
environment of 15°C-30° C (59-86 °F), <85% RH (non-condensing).
• Please use the product indoors without wind.
• When changing to a new environment, please turn on the product and leave
it for 10 to 15 minutes before measuring.
• The ambient temperature for measuring must be stable. Do not measure in
places with large airflow such as fans and air outlets.
• When the measured object comes from a place with a large temperature
difference from the measurement environment, keep it in the measurement
environment for 10 to 30 minutes before measuring.
• The product tests the surface temperature of the object. If temperature
compensation is needed, please adjust in the Settings menu.
• The product has a self-calibration function. If the reading jumps quickly,
please read the temperature after it gets steady.
• After measuring extremely high or low temperature objects, please leave the
product for 10 minutes before next use.
• Do not use the product in places with strong sunlight or electromagnetic
interference.
• Please do not use this product in flammable, explosive, steamy, wet or
corrosive environments.
• Please stop using the product if it is damaged or modified to avoid inaccurate
measurement results.
• Please use the correct emissivity to obtain accurate temperature readouts.
To ensure accuracy of the product, please warm it up for 10 minutes before
measuring if it has not been used for a long time.
• When being charged, the internal temperature of the product rises, which
will lead to inaccurate temperature measurement. So, it is not
recommended to take measurements during or right after charging the
product.
• The inherent temperature drift of the sensor will occasionally cause
inaccurate measurement. In this case, press the down button under the
temperature measurement interface to bring out “Calibrating” and
automatically calibrate the temperature.
4

FFim100 User Manual
FFim100 User Manual
7
2. Structure
Item
Description
Item
Description
1
Micro SD card slot
10
Tripod mounting hole
2
Type-C USB interface
11
Flashlight button
3
Interface cover
12
Left button
4
LED light
13
Down button
5
Infrared camera lens cover
14
Right button
6
Trigger
15
Back button
7
Infrared camera lens
16
Replay button
8
LCD
17
Up button
9
Power button
18
SET button

FFim100 User Manual
8
3. Display
Display size: 2.8”
Display resolution: 320 (vertical) x 240 (horizontal) pixels
4.
Power On/Off
Press the power button for 3s to power on, and press the power button for
1s to power off.
Item
Description
Item
Description
1
Temperature unit option
8
Maximum temperature point
2
Cursor option
9
Center point
3
Color palette option
10
Center point temperature
4
High/Low temperature alarm
11
Maximum temperature
5
Settings option
12
Date & time
6
Temperature bar lower value
13
Battery status
7
Temperature bar upper value
Item
Description
Item
Description
1
Temperature unit option
8
Maximum temperature point
2
Cursor option
9
Center point
3
Color palette option
10
Center point temperature
4
High/Low temperature alarm
11
Maximum temperature
5
Settings option
12
Date & time
6
Temperature bar lower value
13
Battery status
7
Temperature bar upper value
Item
Description
Item
Description
1
Temperature unit option
8
Maximum temperature point
2
Cursor option
9
Center point
3
Color palette option
10
Center point temperature
4
High/Low temperature alarm
11
Maximum temperature
5
Settings option
12
Date & time
6
Temperature bar lower value
13
Battery status
7
Temperature bar upper value
6

FFim100 User Manual
FFim100 User Manual
9
5. Menu Introduction

FFim100 User Manual
10
6. Operating Instructions
6.1 Temperature Unit Selection
1. Press the SET button to open the main menu.
2. Press the left/right button to select the option.
3. Press the SET button to enter the temperature unit submenu.
4. Press the up/down button to select °C or °F.
5. Press the back button to exit the current menu.
6.2 Center Point and High Temperature Tracking
To track center point temperature:
1. Press the SET button to open the main menu.
2. Press the left/right button to select the option.
3. Press the SET button to enter the cursor submenu.
4. Press the up/down button to select the option.
5. Press the SET button to confirm.
6. The center point marker is turned on (the center point temperature
is displayed in the upper left corner).
7. Press the back button to exit the current menu.
8
Indice
Altri manuali FeverFinder Telecamera termica