FFD POWER SOLE 5000 Manuale utente

Installation and User Manual
51.2V/100AH LiFePO4 battery for solar energy storage
SOLE 5000

ATTENTION: The battery could explode and/or be severely damaged if
dropped or crushed.
ATTENTION: Appropriate mechanical lifting equipment must be used since the
Battery Module weighs 126.3 lb /57.3 kg
ATTENTION: The battery may explode if exposed to open flames or other ex-
treme sources of heat.
ATTENTION: The battery terminals must be disconnected before commencing
any work on the battery.
ATTENTION: This battery can accumulate parasite current. Do not touch the
B+ and B- terminals. Always check the B+ and B- terminals with a voltmeter.
Always ensure that there are ZERO volts present on the terminals before per-
forming any operation on the battery.
ATTENTION: Always wear Individual protection devices, use insulated tools,
and follow the safety plan of this manual. At end of life, these batteries must be
disposed of properly by a certified professional company.
At end of life, these batteries must be disposed of properly by a certified
professional company.

Statement:
The information and guidance contained in this manual is related to the SOLE 5000 low level model of battery.
In case of product upgrades or other reasons, this document will be adjusted accordingly. Unless otherwise agreed, this
document is intended to be used only as a guide, and all statements, information and advice in the documentation shall not
constitute any express or implied action in contradiction to local regulations or standards.
For more information, please contact us.
The official information and the latest datasheet are available on www.ffdpower.com
It is essential that the Battery Module is equipped with the latest firmware version available.
New batteries always ship with the latest version of firmware.
From time to time, firmware will be updated to improve the functionalities and battery capabilities. The latest version of
the firmware is always available free of charge and can be updated by your local installer. You can always contact in-
fo@ffdtec.com for additional information on the upgrade procedure.
NOTICE: This Battery Module is designed to be used indoors. The standard IP21
degree of protection does not allow installation in outdoor environments even if
sheltered from the weather. The Battery Modules must be stored indoors in a clean,
dry, cool location in a limited access area
Preface:
Thank you for choosing our product. We will provide you with a high-quality product as well as reliable after-sale service.
To protect against harm to both personnel and the product, please read this manual carefully.
This manual provides detailed information on operation, maintenance and troubleshooting of the product as well as health
and safety advice.
Declaration:
The manufacturer holds the right of final explanation of any content in this manual.
All trademarks shown in this manual belong to their legitimate owners; trademarks of third parties, product names, trade
names, corporate names and companies mentioned may be trademarks owned by their respective owners or registered
trademarks of other companies and are used purely for explanatory purposes and for the benefit of the owner, without any
purpose of violation of the copyright in force.

The System Design
System Design is the process of defining the architecture, components, modules, interfaces and load data for a system to
satisfy specified requirements.
For a solar energy system, these components are the PV modules, inverter/charge controller & batteries, as well as the
different interfaces of those components.
Battery Operation
There are several factors that affect the operation of the battery that could impact its ability to deliver capacity and life
expectancy.
Storage
Battery Module shall be stored in original packaging, in a clean, level, dry, cool location indoors.
Recommended storage temperature is 77°F (25°C).
The battery can be stored in the range of -4°F to +113°F (-20°C to +45°C) but it requires an inspection and recharge every
three months (max charging current is 0.1C).
Max SoC storage % is 50%.
Max Transportation SoC is 30% in accordance with UN 38.3 Prescriptions
Temperature
Many chemical reactions are affected by temperature, and this is true of the reaction that occurs in a storage battery.
The chemical reaction of a Li-Ion is slowed down by a lowering of the electrolyte temperature that results in less capacity.
A battery that will deliver 100% of rated capacity at 77°F (25°C) will only deliver approximately 75% of rated capacity at
+50°F (+10°C).
At temperatures down to +19.4°F (+7°C) the charge current may be limited to 0.1C depending on other factors, however
at temperatures below +19.4°F (-7°C) charging is restricted by the BMS.
As part of the Performance Warranty, Charge and Discharge shall be in the range +68°F to +77°F (+20°C to +25°C). Any
usage outside this range is not covered by Performance Warranty.
Depth of Discharge (DoD)
Depth of discharge is a function of design. The deeper the discharge per cycle, the shorter the life of the battery. A cycle is
a discharge and its subsequent recharge regardless of depth of discharge.
Charging
The majority of battery capacity/life issues can be traced to improper charging. Improper charging settings may lead to an
overcharging or undercharging condition.
Warranty
Although the BMS of the battery allows a wide range of use, both in terms of temperature and charging currents, this
should not be construed as an implicit authorization to use the battery at these levels. For the purposes of the Performance
Warranty, it is mandatory that the battery is used within the range of temperature and charge/discharge current, and Depth
of Discharge indicated in the Performance Warranty. Warranties only apply to batteries connected via BMS line to an
approved inverter. Any other use, even if permitted by the BMS ranges, is not covered by the Performance Warranty.

Product Overview
The FFD SOLE 5000 is a Stackable Battery that can be used in a Low Voltage configuration. For LOW VOLTAGE
(Max 58.4 Vdc)* Configuration Refer to Section 2 *Voltage ranges are estimates only as they always depend on interac-
tions with other devices and ambient conditions.
Information in this Manual
About this Manual This manual relates only to the FFD SOLE 5000 Stackable Battery Module. Only trained and quali-
fied installers should install, repair or charge these Battery Modules. This manual should be reviewed in its entirety for
proper storage, installation and operation of the Battery Module.
Use Range T
his installation guidance applies for the Low Voltage Inverters. Make sure to use the correct inverter charging parameters
before connecting to the battery. Each FFD SOLE 5000 Battery Module has two different circuits and depending on the
inverter voltage range, the installer must choose the correct battery configuration for that range.
Additional Information
Product specifications subject to change without notice.
Symbols Used
Symbol Meanings:
CAUTION represents hazardous situations which can cause injuries if not avoided.
NOTICE represents the situations which can cause damage to property if not avoided.
INFORMATION provides tips that are valuable for optimum installation and operation
of the product
Caution Information Notice

BATTERY OVERVIEW:
INFORMATION provides tips that are valuable for optimum installation and operation of the product.
SOC LED
Power button
Setting Screen
Removable cable installation handle
Removable connector cover
Wall bracket
Fixed handle
Cable Cover

Safety
Warnings and Notifications
Installation environment requirements: The FFD Module SOLE 5000 Stackable Battery Module is designed for
household/commercial purposes. For installation, it must be installed in a location complying with IP20
(IP 55 or 65 are available on request). Installations in locations that do not comply with IP20 may cause
failure and/or damage to the product, in which case the product warranty will become void.
Safety Guidelines
Caution
Adequately insulated tools up to 1500V shall be used at all times to ensure battery terminals are not short circuited. All
electrical connections on the FFD Module SOLE 5000 Battery Module shall be made only by qualified personnel.
When installed and operated in accordance with this manual, the FFD Module SOLE 5000 Battery Module will perform
in a safe and reliable manner in accordance with the battery operating specifications.
Subjecting the battery to an unsuitable operating environment or to damage, misuse or abuse may result in health and
safety risks such as overheating or electrolyte smoke potential. All personnel must comply with the safety precautions and
observe all warnings as detailed in this document. If any of the safety precautions or procedures detailed in this manual
are not fully understood by the reader, the reader must not perform any operation on the battery until they have contacted
the FFD MODULE technical service representative for clarification and confirmation of understanding of the correct
procedure.
The safety guidelines included in this document may not include or consider all the regulations in your area of installa-
tion/operation. When installing and operating this product, the installer must review and consider applicable Federal,
State and Local laws and regulations in accordance with the industry standards of the product.
Installation personnel shall not wear metallic objects, such as watches, jewelry and other metal items when performing
installations. Do not store un-insulated tools in pockets or tool belt while working in vicinity of battery to avoid short
circuits and personal injuries.
Caution
The weight of an individual FFD Module SOLE 5000 Battery Module is 126.3 lb / 57.3 kg.
Please use original packaging and follow all safety precautions if the Battery Module is to be relocated to another loca-
tion, to avoid damage to the product and personal injury.

General preparation
Before Installation:
Ensure that all the modules are turned OFF.
Battery installation location should be at least 20m away from sources of heat, sparks or other sources of extreme temper-
ature. Battery connecting cables shall be as short as possible to prevent excessive voltage drops.
Batteries with different capacity, different type/model or design or from different manufacturers shall not be connected
together.
1.Before connecting the battery, the battery positive and negative poles shall be carefully checked to ensure correct instal-
lation.
2.The installation location must be on a flat level surface, in a dry, clean and protected room, away from water and hu-
midity.
Before starting any operation on the battery, make sure to position the modules in their final position and structurally fix
all the modules that make up the system.
Wall/Floor mounted
With bracket and cable cover
Stack mounted
Without bracket and cable cover

STACKABLE INSTALLATION INFORMATION
The stack configuration shall be concluded by interlocking the modules by using the Stopper/ Retainer plate as shown
below:
Step 1> Install the removable handle on the lower battery module ,Position the lower battery module on the selected in-
stallation position
Step2 > Take away the removable handle and fix Stopper / Retainer plate on the bottom and left side of lower battery
module
Sep3> Position the second battery module on the face of lower battery module with removable handle
Sep4> Remove the left removable handle of second battery module and regulate its position to fix Stopper/Retainer plate
with screw , then take away removable handle on the right side of second battery module
Stopper and Retainer
Removable handle

STORAGE & PRE-OPERATIONAL PROCEDURES
1.1 Storage - Transportation – Removing / Relocation of Batteries
This Battery is considered DANGEROUS GOODS by the United Nations and must be treated accordingly.
Each box comes from the factory with the below labels:
This battery can only be transported and stored with the original approved carton box, Certified as per UN
CLASS 9 Y80.
This Battery must be stored in its original carton box in a dry and cool place.
• The transportation and Storage State of Charge (SoC) shall not exceed 50%.
• The shelf period without recharging is 6 months, and then requires a quick charge up to 70% DoD and
discharge back to 50% at 0.5C / 77°F (25°C).
• To preserve the performance and shelf life, this battery should optimally be stored at 77°F (25°F) and
@70% humidity.
• Acceptable storage temperature range of the battery is between +59°F and +95°F (+15°C and +35°C).
• The self-discharge in the range of +59°F to +119°F (+15°C to +35°C) is around 1% a month. Any-
thing outside this range could exceed 10% a month.
• Do not store the batteries near sources of heat, vapor, gas, fuels, sparks or anything that could generate
fire or explosion.
• Store inside and protect from water and moisture.
• Transportation of new and used or damaged modules must be in accordance with the UN 38.3 Regula-
tion and with the Federal, State and Local regulations.
• If one or more working Battery Modules need to be removed or relocated, they must be marked as
USED BATTERY (follow local rules).
• If one or more Battery Modules need to be replaced due to damage, they should be marked as DAM-
AGED USED BATTERY and follow any applicable procedures and all Federal, State and Local regu-
lations.
Indice

















